Features
- Current rating 25 and 40 Amps
- Output voltage 24-280 VAC and 48-660 VAC
- Direct bond copper substrate
- Back to back dual SCR output
- 4000 VAC optical isolation
- Zero Voltage and Instantaneous Turn-On
- UL/cUL Recognized, CE Compliant 1/4” Quick Connect 280 VAC 1/4” Quick Connect 660 VAC Locking Connector 280 VAC Control Voltage 25 A 40 A 25 A 40 A 25 A 40 A 4-15 VDC 84140000 84140200 84140500 84140600 84140800 84140900 17-32 VDC 84140410 84134210 84140510 84140610 84140810 84140910 Output Specifications (1) Description 280 VAC 660 VAC Operating Voltage [Vrms] 24-280 48-600 Transient Voltage(t=1 min.) [Vpk] 550 1000 Maximum Off-State Leakage Current @ Rated Voltage (@ max. line voltage) [mArms] 0.1 0.25
www.sensata.comCopyright © 2018 Sensata Technologies, Inc. Input Specifications (1) General Specifications (1) Description Parameters Ambient Operating Temperature Range -40 to 80°C Ambient Storage Temperature Range -40 to 100 °C Input to Output Isolation 4000 Vrms Input/Output to Ground Isolation 2500 Vrms Input to Output Capacitance 8 pF Operation Frequency 47 to 63 Hz Housing Material UL94 V-0 (self extinguishing) Weight (typical) 3.2 oz (91.5g) Output Specifications (1) Description 25 A 40 A Maximum Load Current [Arms] 25 40 Minimum Load Current [mArms] 100 100 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 275/300 710/750
1 Second surge current (50/60 Hz @ Ta=25°C) [Apk] 85 150
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.4 1.3 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.6 0.4 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 380/370 2520/2320 Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 Description 84140x0x 84140x1x Control Voltage Range [Vdc] 4-15 17-32 Minimum Turn-On Voltage [Vdc] 4 17 Must Turn-Off Voltage [Vdc] 1 1 Minimum Input Current (for on-state) [mA] 7.5 13 Maximum Input Current [mA] 34 24 Nominal Input Impedance [Ohms] 500 1500 Maximum Turn-On Time [msec] (2) 1/2 Cycle Maximum Turn-Off Time [msec] 1/2 Cycle MECHANICAL SPECIFICATIONS (1) Tolerance: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Input A Input B+ pl i fa=pq ^qb=obi ^v 0.60 [15.2] 0.56 [14.3] 0.18 [4.7] 2.30 [58.4] 0.74 [18.8] 0.45 [11.5] 1.87 [47.5] 1.31 [33.2]0.86 [21.8] 1.21 [30.6] Mating Connector for 841408xxx and 841409xxx Molex # 50-57-9404 without pins Crimp Pins Molex # 16-02-0103 1.00 [25.4] 1.17 [29.7] 1.78 [45.3] Pin .025 SQ .100 CENTERS (4 places) Mounting Hole/Slot 0.19 [4.9] DIA.
www.sensata.comCopyright © 2018 Sensata Technologies, Inc. WIRING DIAGRAM EQUIVALENT CIRCUIT BLOCK DIAGRAMS THERMAL DERATE INFORMATION
www.sensata.comCopyright © 2018 Sensata Technologies, Inc. ORDERING OPTIONS Example : 84140010 Family 1/4” Quick Connect 280 VAC 1/4” Quick Connect 660 VAC Locking Connector 280 VAC Rated Load Current 1/4” Quick Connect 280 VAC 0 : 25 Amp/Zero Voltage Turn-On 1 : 25 Amp/Instantaneous Turn-On 2 : 40 Amp/Zero Voltage Turn-On 3 : 40 Amp/Instantaneous Turn-On 1/4” Quick Connect 660 VAC 5 : 25 Amp 6 : 40 Amp Locking Connector 280 VAC 8 : 25 Amp 9 : 40 Amp Control Voltage 1/4” Quick Connect 280 VAC 0 : 4-15 VDC 1 : 17-32 VDC 1/4” Quick Connect 660 VAC 0 : 4-15 VDC 1 : 17-32 VDC Locking Connector 280 VAC 0 : 4-15 VDC 1 : 17-32 VDC Operating Voltage 1/4” Quick Connect 280 VAC 0 : 24-280 VAC 1/4” Quick Connect 660 VAC 0 : 48-660 VAC/Zero Voltage Turn-On 1 : 48-660 VAC/Instantaneous Turn-On Locking Connector 280 VAC 0 : 24-280 VAC/Zero Voltage Turn-On 1 : 24-280 VAC/Instantaneous Turn-On 84140 0 1 0 GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Turn-on time for Instantaneous turn-on versions is 0.02 msec. For additional information or specific questions, contact Crydom Technical Support.
+1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 www.sensata.com CONTACT USCopyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev:12/04/18 ECN 20395 FDE-07-01 Rev. B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. AGENCY APPROVALS & CERTIFICATIONS Certified according to EN 62314:2006 IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3