834-00002F EEMAGNETIC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
- The maximum volt-msec rating limits the peak flux density to 2200 Gauss when used in a unipolar drive application. For bi-polar drive application, a maximum volt-msec of two times this rating is acceptable. 3. Leakage inductance is measured at primary terminals with all secondaries shorted. Part Number Operational Insulation Basic Insulation (1.4mm creepage and clearance between Primary and Secondary) Hipot Primary Inductance (uH Min) Leakage Inductance Max V.msec Package Size (L x W x H) (uH Max) 1.60 0.91 0.91 0.91 2.00 0.75 0.80 0.60 1.60 0.46 0.91 0.38 2.00 0.75 0.80 0.60 45.1 27.2 27.2 27.2 23.8 12.7 9.3 9.7 9.0 x 8.6 x 7.6 9.0 x 8.6 x 7.6 9.0 x 8.6 x 7.6 9.0 x 8.6 x 7.6 8.0 x 6.6 x 5.3 8.6 x 6.7 x 3.6 7.2 x 5.1 x 3.8 9.1 x 6.6 x 2.5 DCR Primary DCR SecondaryTurns Ratio 3300 1200 1200 1200 300 1140 600 785 (W Max) (W Max) (mm Max) 0.70 0.60 0.50 0.68 0.50 0.65 17.00 0.46 1 : 1 : 1 2 : 1 : 1 1 : 1 2.5 : 1 : 1 1 : 1 : 1 1 : 1 : 1 1 : 1 1 : 1 1500Vdc 1500Vrms 1500Vrms 1500Vrms 1500Vdc 1500Vdc 1500Vdc 1500Vdc 834-00002F 834-00011F 834-00022F 834-00023F 834-00003F 834-00006F 834-00007F 834-00012F SCHEMATICS SCHEMATICS SCHEMATICS SCHEMATICS 1500Vdc Isolation between Gate and Drive Basic insulation (1.4mm creepage / clearance) and Operation frequency: 50kHz minimum RoHS compliant Custom design is also available Operating temperature -40°C to +125°C. ELECTRICAL SPECIFICATION @ 25°C operational insulation is available Notes: 4. Operating temperature range: -40 °C to +130 °C. The part temperature (ambient temperature + temperature rise) should not exceed the upper limit of the operating temperature under worst case operating conditions. Circuit design, component placement, PWB trace size and thickness, airflow and other cooling provisions all af fect the part temperature. Part temperature should be verified in the end application. 834-000xxF 1. Ordering Information: 834-000xxFc. = Part number (F : stands for RoHS compliant). c = Packaging Code (T = Tape & Reel Packaging in 13 inch Reel). Revised in 11/12PG001(02) E & E Magnetic Products Limited SMT GATE DRIVE TRANSFORMER Basic and Operational Insulation 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Hong Kong Tel: (852) 2954 3333 Fax: (852) 2954 3304
.073± 1.85± .005 0.13 .260
6.60 MAX
.315
8.00 MAX
MAX.210 5.33 4 .330 8.38 .146 3.71 .050 1.27 .073 1.85 .050 1.27 4-003F EE Recommended Pad Layout (DATE) .030± 0.76± .010 0.25 Weight (in gram) : 0.50 typ. Tape & Reel : 800 / reel .010 0.25U .nless otherwise specified, all tolerances are ± .146± 3.70± .005 0.13 MECHANICAL DIMENSIONS SCHEMATICSSCHEMATICS PACKAGING USER DIRECTION OF UNREELING 1.55 6.3012.00 16.00 7.50 1.754.00 0.50 2.00 8.20 5.60 4-003F EE (DATE) Revised in 11/12PG001(02) E & E Magnetic Products Limited SMT GATE DRIVE TRANSFORMER Basic and Operational Insulation 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Hong Kong Tel: (852) 2954 3333 Fax: (852) 2954 3304
834-00002F / 834-00011F / 834-00022F / 834-00023F Weight (in gram) : 0.65 typ. Tape & Reel : 600 / reel .010 0.25U .nless otherwise specified, all tolerances are ± 88 5 834-00002F / 834-00011F / 834-00023F 834-00022F Reference or Gauge Plane 34-0xxF (DATE) .340 8.64 .320 8.13 .050 1.27 .300 7.62 .070 1.78 MAX .355
9.02 MAX
.300± .010 7.62 0.25 MAX Recommended PAD Layout .300 7.62 .270± .010 6.86 0.25.100± .010 2.54 0.25 MECHANICAL DIMENSIONS SCHEMATICSSCHEMATICS PACKAGING 34-0xxF (DATE) 12.00 8.757.80 16. 07.50 .20 USER DIRECTION OF UNREELING
3 Revised in 11/12PG001(02)
E & E Magnetic Products Limited SMT GATE DRIVE TRANSFORMER Basic and Operational Insulation 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Hong Kong Tel: (852) 2954 3333 Fax: (852) 2954 3304
Weight (in gram) : 0.23 typ. Tape & Reel : 1200 / reel .010 0.25U .nless otherwise specified, all tolerances are ± Reference or Gauge Plane 1 2 3 6 5 4 34-006F (DATE) .340
8.64 MAX
.265
6.73 MAX
.200± .010 5.08 0.25 MAX.140 3.56 .280± .010 7.11 0.25.100± .010 2.54 0.25 .320 8.13 .200 5.08 .070 1.78 .100 2.54 .050 1.27 Recommended Pad Layout SCHEMATICSSCHEMATICS PACKAGING MECHANICAL DIMENSIONS 12.00 8.754.00 16. 07.50 123 654 34-006F (DATE) USER DIRECTION OF UNREELING Revised in 11/12PG001(02) E & E Magnetic Products Limited SMT GATE DRIVE TRANSFORMER Basic and Operational Insulation 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Hong Kong Tel: (852) 2954 3333 Fax: (852) 2954 3304
.050 1.27 .035 0.89 REFERENCE OR GAUGE PLANE .150±.005 3.81±0.13 .300±.010 7.62±0.25 .200±.010 5.08±0.25 .250±.010 6.35±0.25 .310 7.87 .065 1.65 .150 3.81 .150
3.81 MAX
.050±.005 1.27±0.13 .004-.012 0.10-0.30 .030±.005 0.76±0.13 .200
5.08 MAX
.025±.008 0.64±0.20 Recommended Pad Layout 34-007F EE (DATE) Weight (in gram) : 0.65 typ. Tape & Reel : 1100 / reel 1 8 4 5 834-00007F MECHANICAL DIMENSIONS SCHEMATICSSCHEMATICS PACKAGING .010 0.25U .nless otherwise specified, all tolerances are ± USER DIRECTION OF UNREELING 5.60 16.0 12.00 8.204.30 34-007F EE (DATE) Revised in 11/12PG001(02) E & E Magnetic Products Limited SMT GATE DRIVE TRANSFORMER Basic and Operational Insulation 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Hong Kong Tel: (852) 2954 3333 Fax: (852) 2954 3304
Weight (in gram) : 0.15 typ. Tape & Reel : 1800 / reel .010 0.25U .nless otherwise specified, all tolerances are ± 1 6 3 4 Reference or Gauge Plane 1 2 3 6 5 4 34-012F (DATE) .360
9.14 MAX
.260 .200± .010 5.08 0.25 MAX.098 2.50 .280± .010 7.11 0.25.100± .010 2.54 0.25 .325 8.26 .050 1.27 .200 5.08 .060 1.52 Recommended PAD Layout HEADQUARTER Hong Kong Email: eempl@eleceltek.com Website: http://www.eleceltek.com / www.eemagnetic.com Information herein is for reference only and subject to change without notice. It does not constitute any representation, warranty or commitment of the company in respect of the products in any aspect. All logos, brands and product names mentioned herein are trademarks or registered trademarks of their respective owners. The company does not assume any liability arising out of the application or use of any product or circuit described herein. Copyrights 2009, E & E Magnetic Products Limited. FOR MORE INFORMATION, PLEASE CONTACT HEADQUARTER 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Tel: (852) 2954 3333 Fax: (852) 2954 3304 Information herein is for reference only and subject to change without notice. It does not constitute any representation, warranty or commitment of the company in respect of the products in any aspect. All logos, brands and product names mentioned herein are trademarks or registered trademarks of their respective owners. The company does not assume any liability arising out of the application or use of any product or circuit described herein. Copyrights 2009, E & E Magnetic Products Limited. FOR MORE INFORMATION, PLEASE CONTACT SCHEMATICSSCHEMATICS PACKAGING 123 654 34-012F (DATE) 12.00 9.303.00 USER DIRECTION OF UNREELING MECHANICAL DIMENSIONS Revised in 11/12PG001(02) E & E Magnetic Products Limited SMT GATE DRIVE TRANSFORMER Basic and Operational Insulation 1/F., Harbour View 1, No.12 Science Park East Avenue, Phase II, Hong Kong Science Park, Shatin, N.T. Hong Kong Tel: (852) 2954 3333 Fax: (852) 2954 3304