SENSOR SOLUTIONS /// Model 832M1 Rev F 9/2015 Page 1 MODEL 832M1 ACCELEROMETER SPECIFICATIONS Triaxial Piezoelectric Accelerometer <22µA Current Consumption Wide Bandwidth to 6kHz Circuit Board Mountable The Model 832M1 is a low cost, board mountable triaxial accelerometer. Featuring stable piezo-ceramic crystals, the accelerometer incorporates full power and signal conditioning with a maximum current consumption of 22 micro-amps. The model 832M1 is available in ±25g to ±500g ranges and provides a flat frequency response up to greater than 6kHz. The standard model 832 offers the same envelope with a lower maximum current consumption of 4 micro-amps.
FEATURES
±25g to ±500g Dynamic Range Low Cost Triaxial Hermetically Sealed Piezo-ceramic Crystals -40° to +125°C Operating Range Single Axis Configurations Available
APPLICATIONS
Asset Monitoring Data Loggers Impact Monitoring Machine Health Monitoring System Wake-Up Switch Embedded Applications DIMENSIONS
SENSOR SOLUTIONS /// Model 832M1 Rev F 9/2015 Page 2 PERFORMANCE SPECIFICATIONS All values are typical at +24°C, 80Hz and 3.3Vdc excitation unless otherwise stated. Measurement Specialties reserves the right to update and change these specifications without notice. Parameters DYNAMIC Notes Range (g) ±25 ±50 ±100 ±200 ±500 Frequency Response (Hz) 2-6000 2-6000 2-6000 2-6000 2-6000 ±2dB Natural Frequency (Hz) >10000 >10000 >10000 >10000 >10000 Non-Linearity (%FSO) ±2 ±2 ±2 ±2 ±2 Transverse Sensitivity (%) <10 <10 <10 <10 <10 Shock Limit (g) 5000 5000 5000 5000 5000 ELECTRICAL Bias Voltage (Vdc) Exc Voltage / 2 Exc Voltage / 2 Exc Voltage / 2 Exc Voltage / 2 Exc Voltage / 2 Total Supply Current (µA) 1 <22 <22 <22 <22 <22 Output Impedance (Ω) <100 <100 <100 <100 <100 Insulation Resistance (MΩ) >100 >100 >100 >100 >100 @100Vdc Broadband Noise (µV) 110 90 50 40 50 2Hz-10kHz Spectral Noise (µg/√Hz) 120 160 160 160 600 @ 10Hz Spectral Noise (µg/√Hz) 40 40 40 40 160 @ 100Hz Spectral Noise (µg/√Hz) 20 16 16 16 80 @ 1000Hz Warm-Up Time (msec) 30 Shielding 100% Ground Isolation Isolated from Mounting Surface ENVIRONMENTAL Temperature Response (%) -20/+30 from -40°C to +125°C Operating Temperature (°C) -40 to +125 Storage Temperature (°C) -40 to +125 PHYSICAL Sensing Element Ceramic (shear mode) Case Material Ceramic Base, Nickel Silver Cover Weight (grams) 3.0 1 A lower current consumption of 4 micro-amps is available on model 832. 2 The model 832M1 is not to be reflow soldered at high temperature, manual soldering is recommended. See application note. 3 The model 832M1 can be operated with 2.8V excitation but the full-scale range will be limited. Calibration supplied: CS-SENS-0100 NIST Traceable Amplitude Calibration at 100Hz The information in this sheet has been carefully reviewed and is belie ved to be accurate; however, no responsibility is assumed for inaccuracies. Fu rthermore, this information does not convey to the purchaser of such devices any license u nder the patent rights to the manufacturer. Measurement Specialties, Inc. r eserves the right to make changes without further notice to any product herein. M easurement Specialties, Inc. makes no warranty, representation or guaran tee regarding the suitability of its product for any particular purpose, nor does Measureme nt Specialties, Inc. assume any liability arising out of the application or use o f any product or circuit and specifically disclaims any and all liability, including without limitatio n consequential or incidental damages. Typical parameters can and do v ary in different applications. All operating parameters must be validated for each customer appli cation by customer’s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
SENSOR SOLUTIONS /// Model 832M1 Rev F 9/2015 Page 3
ORDERING INFORMATION
PART NUMBERING Model Number+Range 832M1-GGGG l l_____ Range (0200 is 200g) Example: 832M1-0200 Model 832M1, 200g TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believe d to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations sha ll only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2015 TE Connectivity Ltd. family of companies All Rights Reserved. NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company
1000 Lucas Way
Hampton, VA 23666 Sales and Customer Service Tel: +1-800-745-8008 or +1-757-766-1500 Fax: +1-757-766-4297 t&m@meas-spec.com EUROPE MEAS France SAS a TE Connectivity Company
26 Rue des Dames
F78340 Les Clayes-sous-Bois France Sales and Customer Service Tel: +33 (0) 1 79 33 00 Fax: +33(0)1 34 81 03 59 t&m@meas-spec.com ASIA Measurement Specialties (China), Ltd., a TE Connectivity Company No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen 518057 China Sales and Customer Service Tel: +86 755 3330 5088 Fax: +86 755 3330 5099 t&m@meas-spec.com