All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet SPECIFICATIONS Available Pressure Measurement Accuracies: AQS-1 Module Type: ±0.06% (0.07%) or 0.1% of span AQS-2 Module Type: ±0.025%, 0.05% or 0.1% of span Display: Standard: Alphanumeric LCD, 0.37-inch height, 2 lines, 16 characters/line Optional: Backlit LCD Display Resolution: ±0.002% of span, 60,000 counts (max) Display Update Rate: 130 ms (nominal) with one sensor installed Engineering Units: psi, in. H2O, in. Hg, ftSW, bar, mbar, kPa, MPa, mm Hg, cm H2O, mm H2O and kg/cm2 and any single user-programmable engineering unit Damping: Programmable averaging from zero through 16 consecutive readings Standard Operating Range: 32 °F to 120 °F (0 °C to 49 °C) Compensated Range: 20 °F to 120°F (-7 °C to 49 °C) Reference Temperature 70 °F ±3 °F Standard Temperature Effect: 0.004% of span per degree Fahrenheit over the compensated range Optional Extended Temperature Compensation: AQS-2 Quick-Select™ modules are available calibrated to maintain rated accuracy over the 20 °F to 120 °F (-7 °C to 49 °C) compensated temperature range. Storage Temperature: -4 °F to +158 °F (-20 °C to 70 °C) Electrical Sourcing: 24 Vdc at 25 mA Electrical Measurement Specification:: Input (volts) Accuracy: 0/10 Vdc ±0.025% of span 0/30 Vdc ±0.10% of span Input (mA) Accuracy: 0/20 mA ±0.03% with of span Temperature Effects Electrical Measurement: ±0.001% of span per °F over the compensated range (Reference temp. 70 °F ± 3 °F)

FEATURES

Benchtop indicator able to measure up to 3 parameters; pressure, temperature, voltage or current Interchangeable pressure modules with pressure ranges from 0.25 in. H2O up to 10,000 psi Measurement accuracy +/- 0.1%, 0.05% or 0.025% of span RS232 serial communication Traceable calibration certificate included with base and modules ST-2A Digital Indicator KEY BENEFITS

  • Measurement flexibility of interchangeable Quick- Select™ calibrator modules
  • Built in functions including leak detect, flow measurement and datalogging Weight: ST-2A Base unit: 3.0 lb (1.4 kg) Housing: Molded, high-impact ABS case Electrical Connections: Standard banana jacks Optional Battery Power Supply: 5 “AA” nicads with built-in charger or 5 “AA” alkaline (nonrechargeable) Portable (Battery) Operation: 20 hours with optional backlight off, 2 hours with backlight on External Power Supply: AC adaptor 9 Vdc, 500 mA Warm-up: 5 minutes for rated accuracy (maximum), 30 minutes for complete stability RS232 Serial Interface With 9-pin D type at 300, 1200, 2400, 9600 baud. Field Calibration: Calibration module and proper pressure and electrical standards are required Optional Data Logging Capacity: Standard measurements: 714 records Date/time stamped measurements: 384 records Provides prompts for storage of calibration history information, including instrument tags As Found/As Left data and corresponding ambient temperature SPECIFICATIONS CONTINUED

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet Data Sheet ORDERING CODE Example: ST2H 1 B X D1 X XNH Power Supply 1 - 110 Vac/60 Hz ST2H1 2 - 220 Vac/50 Hz 3 - 100 Vac/60 Hz Display N - No backlight B - With Backlight B Standard Temperature X X Datalogging DX - No logging D1 - With logging D1 Approvals X - No approvals X Options X - No options X N - NiCad battery pack (rechargeable) N A - Alkaline battery pack (non-rechargeable) H - Carry handle H L - Loop power supply P - Panel mounting bracket Built in Loop power supply to power device under test (optional). Percent Error Function can be used when calibrating pres- sure transducers. Calculations are performed by the ST-2A eliminating potential for human errors. This function enables the user to program the full scale range and electrical output of the transducer under test, and will display the actual pres- sure and electrical output readings as well as a percentage value comparing the actual output to the theoretical output. Leak Detect provides the ability to detect and quantify leaks in terms of pressure decay over time. In the pressure decay over time mode the unit will monitor the desired pressure vessel for the programmed time interval and, at the end of the monitoring time period, display the measured change in pressure. Switch Test Function the system can be used to test pres - sure and temperature switches. On board firmware provides the ability to verify switch trip points, reset point and to test the dead band of a pressure switch. Data Logging (Optional) Log up to 714 records on internal memory STANDARD FUNCTIONS

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet AQS-1 and AQS-2 Pressure Modules Low pressure modules ranges from 0.25 in. H2O (IWC) to 200 in. H2O (IWC), accuracy ±0.1% to ±0.06% of span, variable capacitance sensor, for use with clean dry gas media Medium/high pressure modules 5 to 10,000 psi, accuracy ±0.1% to ±0.025% of span, 316 Stainless steel isolated sensor, for use with media compatible with 316 Stainless steel Gauge, absolute, differential and compound ranges available Temperature compensated 20 °F to 120 °F PRODUCT SPECIFICATIONS: AQS-1 Low Pressure Modules: Pressure Types: Differential and compound Available Ranges: 0.25 to 200 in. H20 see range table Available Accuracies: ±0.06% of span (0/1-0/200 in. H20) ±0.1% of span Compensated Temperature Range: 20 °F to 120 °F (-7 °C to 49 °C) Temperature Effect: ±0.004% of span per °F over compensated range from reference temperature range of 70 °F (±3 degrees) Repeatability: ±0.01% of span (range 0/1 in. H20 or higher) ±0.02% of span (range below 1.0 in. H 20) Sensitivity: ±0.002% of span (typical) Under / Overpressure Capability: -15 to 50 psi Maximum Static (line) Pressure: 100 psi Process Connection: 1⁄8 NPT Female (STD.) Media Compatibility: Clean, dry, non-conductive, non-corrosive gas PRODUCT SPECIFICATIONS: AQS-2 Medium High Pressure Modules: Pressure Types: Gauge, absolute, compound and vacuum Available Ranges: 5 to 10,000 psi see range table Available Accuracies: ±0.025%, ±0.05% or ±0.1% of span (10,000 psi only offered in psig and ±0.1% accuracy) Compensated Temperature Range: 20 °F to 120 °F (-7 °C to 49 °C) Temperature Effect: Standard: ±0.004% of span per °F over compensated range from reference temperature range of 70 °F (±3 degrees) Optional: Enhanced Accuracy Option — No additional error due to ambient temperature from 20 °F to 120 °F Sensitivity: ±0.002% of span (typical), ±0.001 of span (max) Repeatability: ±0.01% of span Overpressure Compatibility: 200% for ranges to ≤ 1,000 psi 150% for ranges > 1,000 psi Process Connection: 1⁄8 NPT Female (STD.) Optional pressure connec- tions, 1⁄8 NPT Female NPT with flush out port, welded VCR® compatible fitting with standard finish (5,000 psi max) Media Compatibility: Any medium compatible with 316 Stainless steel isolation; 10,000 psi range only available with 17-4 PH® / 316 Stainless steel Optional: Clean to ASME B40-100 Level IV (not marked for oxygen service)

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet Data Sheet ORDERING CODE Example: AQS 1 C A C INWC 5.0 A Model AQS - Low pressure Quick-Select™ calibrator module AQS Sensor Type 1- Capacitive Sensor 1 Accuracy B - ±0.1% Accuracy C - ±0.06% Accuracy (for ranges 1.0 in. H2O and higher) C C - ±0.07% Accuracy (for ranges 0.5 in. H2O and lower) Media Compatibility A - Non-isolated sensor, clean dry gas only A Pressure Type C - Compound C D - Differential Pressure Units INWC - In. H2O INWC Pressure Range Differential 0.25 - IWC (in. H2O) NOTE 1 0.5 - IWC (in. H2O) NOTE 1 1.0 - IWC (in. H2O) 2.0 - IWC (in. H2O) 3.0 - IWC (in. H2O) 5.0 - IWC (in. H2O) 5.0 10 - IWC (in. H2O) 15 - IWC (in. H2O) 25 - IWC (in. H2O) 50 - IWC (in. H2O) 100 - IWC (in. H2O) 150 - IWC (in. H2O) 200 - IWC (in. H2O) Pressure Range Compound 0.125 - IWC (in. H2O) NOTE 1 0.25 - IWC (in. H2O) NOTE 1 0.5 - IWC (in. H2O) NOTE 1 1.0 - IWC (in. H2O) 1.5 - IWC (in. H2O) 2.5 - IWC (in. H2O) 5.0 - IWC (in. H2O) 7.5 - IWC (in. H2O) 12.5 - IWC (in. H2O) 25 - IWC (in. H2O) 50 - IWC (in. H2O) 75 - IWC (in. H2O) 100 - IWC (in. H2O) Inlet Fitting A - 1⁄8 NPT Female A Note (1) Accuracy is _/- 0.07% of span Consult factory for additional pressure units and ranges AQS-1 Low Pressure Quick-Select Pressure Modules

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet ORDERING CODE Example: AQS 2 C I C PSI 30 A Model AQS - Medium high pressure module AQS Sensor Type 2- Piezoresistive sensor 2 Accuracy B - ±0.1% Accuracy (STD.) C - ±0.05 % Accuracy (STD.) C D - ±0.025 % Accuracy (STD.) F - ±0.1% Enhanced temperature compensation 20 °F to 120 °F G - ±0.05% Enhanced temperature compensation 20 °F to 120 °F H - ±0.025% Enhanced temperature compensation 20 °F to 120 °F Media Compatibility I - Isolated 316 Stainless steel wetted parts I W - Cleaned to ASME B40.100 level IV NOT marked for O2 service Pressure Type G - Gauge V - Vacuum C - Compound C Pressure Units PSI - psi PSI Pressure Range - Gauge and absolute (all ranges include 316 stainless steel isolation) 5 psi NOTE 1 10 psi 15 psi 20 psi 25 psi 30 psi 30 50 psi 60 psi 100 psi 150 psi 200 psi 250 psi 300 psi 500 psi 600 psi 1000 psi 1500 psi 2000 psi 2500 psi 3000 psi 5000 psi 6000 psi 7500 psi 10000 psi NOTE 1 Pressure Range - Vacuum 5 psi 10 psi 15 psi (Note 1) Gauge pressure only. Accuracy +/-0.1% of span. Consult factory for additional pressure units and ranges. AQS-2 Quick-Select Medium High Pressure Modules

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet Data Sheet AQS-2 Quick-Select Medium High Pressure Modules AQS-RTD Modules Measures temperature with most RTD probes Supports 2, 3 and 4 - wire RTDs Displays measurement for Farenheit, Celsius, Kelvin Rankine and ohms Easy configurability to meet application PRODUCT SPECIFICATIONS Following specification is based on use of 4 wire RTD probe; accuracy does not include contribution from RT RTD TEMPERATURE MODULE Part Number AQS-RT1 Used with RTD Probe Type Meaurement Range and Accuracy Resolution* Pt100 (385 & 392) - 200 to 550 °C: ±0.15 °C 0.01 °C or °F Ni 120 - 80 to 260 °C: ±0.1 °C 0.1 °C or °F Cu 10 - 70 to 150 °C: ±0. 6 °C 0.1 °C or °F Ohms ±0.01% reading ±0.02 ohms 0.004 ohms RTD TEMPERATURE MODULE Part Number AQS-RT2 Pt1000 - 200 to 550 °C: ±0.15 °C 0.01 °C or °F Ohms ±0.01% reading ±0.02 ohms 0.004 ohms * Select from 1, 0.1, 0.01 and 0.001 degrees or ohms. Resolution for a given probe is dependent on the output of the probe. Maximum resolution is 1 part in 100,000 of full scale ohms Select from 1, 0.1, 0.01 and 0.001 degrees or output for the probe. Temperature Error: Better than ±0.0005% of reading per degree Fahrenheit from a reference temperature of 70 °F ±3 °F Input Receptacle: TA4F type RTD connector HOW TO ORDER RTD PROBES Probes are all 4 wire RTDs with 304 stainless steel sheath and a TA4F electrical connector for compatibility with AM2-RT1 interface modules. They are provided in DIN Class A accuracy. Part No. Description 840X010-01 Pt100 (385), 0.125 diameter, 12 inch length, handle and 5 foot coiled cable 840X010-02 Pt100 (385), 0.25 diameter, 12 inch length, handle and 5 foot coiled cable 840X010-05 Pt100 (385), 0.125 diameter, 6 inch length, handle and 5 foot coiled cable 840X010-06 Pt100 (385), 0.25 diameter, 6 inch length, handle and 5 foot coiled cable 840X010-11 Pt100 (385), 0.125 diameter, 8 inch length, handle and 5 foot coiled cable 840X010-03 Pt100 (385), 0.125 diameter, 12 inch length, 10 foot straight extension lead with plug (no handle) 840X010-04 Pt100 (385), 0.25 diameter, 12 inch length, 10 foot straight extension lead with plug (no handle) 840X010-07 Pt100 (385), 0.125 diameter, 6 inch length, 10 foot straight extension lead with plug (no handle) 840X010-08 Pt100 (385), 0.25 diameter, 6 inch length, 10 foot straight extension lead with plug (no handle) 828X136-01 TA4F mating connector for use with HM2-RT1 module and user supplied RTD probe ORDERING CODE ( continued ) Example: AQS 2 C I C PSI 30 A Pressure Range - Compound 10 - ±10 psi V15 - ±15 psi V30 - ±15/30 psi V60 - ±15/60 psi Inlet Fitting A - 1⁄8 NPT internal A B - 1⁄8 NPT internal with flush port C - G-British standard thread D - G-British standard thread with flush port Consult factory for additional pressure units and ranges, (Note 1) Gauge pressure only and 0.1% accuracy only

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet AQS-TC1 Thermocouple Temperature Modules Allows ST-2A to measure temperature with a thermocouple Pre-programmed to accept 8 most common thermocouple types Displays measurement for Farenheit, Celsius, Kelvin Rankine and millivolts Reference junctions: automatic internal or manual external PRODUCT SPECIFICATIONS: THERMOCOUPLE TEMPERATURE MODULE Part Number AQS-TC Unit of Measure (selectable): °C, °F, °K, °R and millivolts Reference Junction (selectable): Automatic Mode: The AQS-TC1 module incorporates an internal resistor/ thermistor based reference junction, which may be selected for use in the temperature readout mode. Manual Mode: An external reference junction may be used in place of the internal junction. External reference junctions may be applied in the temperature or direct millivolt readout modes. Resolution Reading in Temperature Units (selectable): 1, .1 or .01 degrees. “Auto” mode selection that allows the ST-2A to automatically configure the readout to the highest significant resolution (resolution closest to the tolerance) for the thermocouple type selected. Resolution Reading in Millivolts: .001 millivolts Thermocouple Connection (to interface module): Requires a “miniature thermocouple connector” (Omega type SMP), specifically matched to the thermocouple type to be used. These connectors may be purchased as an accessory under the following part numbers: (see how to order thermocouple connector table) SYSTEM ACCURACY (READING IN TEMPERATURE UNITS): Includes the base unit and AQS-TC1 interface module. (Does not include inaccuracy of the thermocouple device. Consult thermocouple manufacturer or ANSI MC96.1 for thermocouple accuracy specifications. Typical inaccuracies range from ±1 to ±2. °C.) Conversion Factors to convert °C specifications to other units of measure: To convert from C to F; F = (1.8 x C) + 32 To convert from C to K: K = C + 273.15 To convert from C to R; R = (1.8 x C) + 427.6 Additional thermocouple information on the following page. HOW TO ORDER THERMOCOUPLE CONNECTOR Part No. Description 828X161-01 Type J Connector 828X161-02 Type K Connector 828X161-03 Type T Connector 828X161-04 Type E Connector 828X161-05 Type R Connector 828X161-06 Type S Connector 828X161-07 Type B Connector 828X161-08 Type N Connector Thermocouple probes to be provided by customer

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet Data Sheet Thermocouple Type Measurement Range (°C) Accuracy @ 25 °C (Not Including Internal Reference Junction) Accuracy @ 25 °C (Including Internal Reference Junction Expressed as ± °C Max Additional Error Due to Ambient Temperature Deviation From 25 °C Expressed as Additional °C Deviation from 25 °C J -151 to -210 1200 to -150 0.7 0.3 1.1 0.4 0.02 0.01 K -201 to -240 -101 to -200 -999 to -100 1.5 1.0 0.5 2.2 1.5 0.8 0.05 0.03 0.02 T -250 to -201 -200 to -101 -100 to 400 1.5 0.8 0.5 2.2 1.2 0.8 0.05 0.03 0.02 E -250 to -201 -200 to -101 -100 to 400 1.2 0.6 0.3 2.0 1.1 0.6 0.04 0.02 0.01 R & S -50 to 299 300 to 1768 3.4 1.2 3.6 1.3 0.10 0.04 B 100 to 199 200 to 499 500 to 999 1000 to 1820 14.0 5.0 3.0 1.2 14.0 5.0 3.0 1.2 0.44 0.16 0.08 0.04 N -250 to -226 -225 to -101 -100 to 1300 4.3 2.1 1.0 5.7 2.8 1.4 0.14 0.07 0.02 AMBIENT TEMPERATURE EFFECT: To calculate, multiply degrees deviation from 25 °C times the value listed in the far right column of the listed table. Only applied when using the internal reference junction, within the ambient window of 0-50 °C. TO CALCULATE TOTAL SYSTEM/MEASUREMENT ACCURACY: Accuracy = System Accuracy @ 25 °C + System Ambient Temperature Effect + Inaccuracy of Thermocouple Device SYSTEM ACCURACY (BASED ON DIRECT MILLIVOLT READING FROM THERMOCOUPLE): Includes the base unit and AQS-TC1 interface module. (Does not include inaccuracy due to the thermocouple device. Reference junction not applicable to direct millivolt readings.) Input Range of Module Accuracy @ 25 °C Max. Additional Error Due to Ambient Temperature Deviation From 25 °C. Expressed As Additional Millivolt Error Per Each °C Deviation From 25 °C 10 to 100 mV ±0.01 to 100 mV .001 AQS-TC1 Thermocouple Temperature Modules

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Data Sheet DIMENSIONS For reference only, consult Ashcroft for specific dimensional drawings 0.93 0.97 1.44 3.47 4.00 9.240.56 6.74 6.33 3.31 1.511.25 1.10 ADDITIONAL ACCESSORIES Item Part Number Description RS 232 Accessories 838X011-01 Cable assembly, connects base unit to computer with a 9 point serial port. 838X012-01 Adapter, converts connector on cable (838X011-01) to 25 pin type connector on personal computer. Test Leads 836X115-02 Test leads with miniature banana jacks, alligator clips and miniature to standard banana jack adapter. Power Supplies 831X016-01 AC adapter to run system off line power (110 Vac, 60 Hz) 831X016-02 AC adapter to run system off line power (100 Vac, 60 Hz) 831X016-03 AC adapter to run system off line power (220 Vac, 50 Hz) 8361176-01 1.5 volt NiCad battery (5 required) Other quick select modules 840X009-01 AQS-XS For base unit calibration, provides quick access to pins inside module bay “System Protection” module to fill unused module bay in single module applications.