Product: 8310 RS232, Low Cap, #22-10pr, SR-PVC, O/A Foil+Braid, PVC Jkt, CMG Product Description Computer EIA RS-232 Cable, 22 AWG stranded (7x30) tinned copper conductors, semi-rigid PVC insulation, 10 twisted pairs, overall Beldfoil® (100% coverage) + tinned copper braid shield (65% coverage), PVC jacket. Technical Specifications Product Overview Suitable Applications: RS-232 Extended Distance Applications; Computer Communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring Construction Details Conductor Element Number of Element Size Stranding Material Pair(s) 10 22 AWG 7x30 TC - Tinned Copper Insulation Element Material Nom. Thickness Nom. Insulation Diameter Color Code Pair(s) SR-PVC - Polyvinyl Chloride (Semi-Rigid) 0.011 in (0.28 mm) 0.051 in (1.3 mm) Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown, Black & Orange, Red & White, Red & Green, Red & Blue Outer Shield Shield Type Material Coverage Tape Bi-Laminate (Alum+Poly) 100% Braid Tinned Copper (TC) 65% Outer Jacket Material Nom. Thickness Nom. Diameter PVC - Polyvinyl Chloride 0.040 in (1.0 mm) 0.440 in (11.2 mm) Overall Cable Diameter (Nominal): 0.440 in (11.2 mm)
Electrical Characteristics
Element Nom. Conductor DCR Max. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Velocity of Prop. Max. Current Pair(s) 18.2 Ohm/1000ft 9 Ohm/1000ft 35 pF/ft (110 pF/m) 63 pF/ft (210 pF/m) 60% 1.96 Amps per Conductor at 25ºC Voltage UL Voltage Rating
300 V (CMG), 300 V (UL AWM 2464)
Mechanical Characteristics Temperature UL Temperature Operating
80°C -30°C to +80°C Bend Radius Stationary Min. Installation Min. 4.4 in (110 mm) 4.4 in (110 mm) Max. Pull Tension: 182 lbs (82.6 kg) Bulk Cable Weight: 111 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor Flammability / Reaction to Fire: UL 1685 FT4 Loading, FT4 CPR Compliance: CPR Euroclass: Eca NEC / UL Compliance: Article 800, CMG AWM Compliance: AWM 2464 CEC / C(UL) Compliance: CMG European Directive Compliance: EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) UK Regulation Compliance: UKCA Mark APAC Compliance: China RoHS II (GB/T 26572-2011) History Update and Revision: Revision Number: 0.463 Revision Date: 01-20-2023 Part Numbers Variants Item # Color Putup Type Length UPC 8310 060100 Chrome Reel 100 ft 612825203100 8310 060500 Chrome Reel 500 ft 612825203124 8310 0601000 Chrome Reel 1,000 ft 612825203117 © 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.