Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltd en 8.105.350.01 Technical features Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 17 bar (246 psi) Outlet pressure ranges: Filter element: 5 μm & 40 μm Port size: G1/4, G3/8,1/4 PTF, 3/8 PTF Gauge: Integrated as standard Gauge port 1/8 as option Flow: 37 dm³/s at port size 1/4” , 37 dm³/s at port size 3/8” , inlet pressure 10 bar (145 psi) , 6.3 bar (91 psi) set pressure and a Δp: 1 bar (14.5 psi) droop from set. Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0.35 bar (5 psi) Bowl pressure required to open drain: ≤ 0.2 bar (2.9 psi) Minimum air flow required to close drain: 1 dm³/s. Ambient/Media temperature: Polycarbonate bowl: Metal bowl: Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Atex: Filter/regulators B82 are in conformity with Atex 2014/34/EU II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db Materials: Body: Die cast aluminum Body covers: ABS Bonnet: Acetal/ Aluminum Valve: PP Transparent Bowl : Polycar- bonate with Polypropylene Guard. Metal Bowl: Die cast Zinc with PA liquid level indicator lens Filter element: sintered PP Bowl ‘O’- ring: Chloroprene Elastomers: NBR Technical data B82G—standard models *1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren Symbol Port Drain Pressure range (bar) Filter element (µm) Bowl Weight (kg) Model *1) G1/4 Auto 0,3 ... 10 40 Guarded polycarbonate 0,30 B82G-2GK-AP3-RMG G3/8 Auto 0,3 ... 10 40 Guarded polycarbonate 0,30 B82G-3GK-AP3-RMG G1/4 Auto 0,3 ... 10 40 Metal with level indicator 0,50 B82G-2GK-AD3-RMG G3/8 Auto 0,3 ... 10 40 Metal with level indicator 0,50 B82G-3GK-AD3-RMG G1/4 Manual 0,3 ... 10 40 Guarded polycarbonate 0,30 B82G-2GK-QP3-RMG G3/8 Manual 0,3 ... 10 40 Guarded polycarbonate 0,30 B82G-3GK-QP3-RMG G1/4 Manual 0,3 ... 10 40 Metal with level indicator 0,50 B82G-2GK-QD3-RMG G3/8 Manual 0,3 ... 10 40 Metal with level indicator 0,50 B82G-3GK-QD3-RMG > Port size: 1/4” ... 3/8” (ISO G / PTF) > Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products > 5 or 40 micron particle and high efficiency water removal (> 95%) > Double safety lock bowl > Push to lock adjusting knob with built in tamper resistant feature > Metal bowl with prismatic liquid level indicator lens > Light weight Polycarbonate bowl with guard > Easy to read flush mounted integrated pressure gauge > Air purity classes in accordance to ISO8573- 6:8:4 (5μm) B82G - General purpose filter/regulator Excelon® Plus Modular System

psi (bar) 36.3 (2.5) AIR FLOW 0 10 20 30 40 OUTLET PRESSURE 2.0 4.0 6.0 8.0 1.0 3.0 5.0 7.0 AIR FLOW 0 10 20 30 40 OUTLET PRESSURE 2.0 4.0 6.0 8.0 1.0 3.0 5.0 7.0 AIR FLOW 0 10 20 30 40 OUTLET PRESSURE 2.0 4.0 6.0 8.0 1.0 3.0 5.0 7.0 AIR FLOW 0 10 20 30 40 OUTLET PRESSURE 2.0 4.0 6.0 8.0 1.0 3.0 5.0 7.0 B82G–H H H – H H H– R H H Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltden 8.105.350.02 Option selector *1) *3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pres- sures outside of the specified ranges. *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren *2) Units with 246 psi (17 bar) outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th position and S at the 9th position. T-bar handle only available with 17 bar option. Port size Substitute 1/4“ 2 3/8“ 3 Thread form Substitute PTF A ISO G (standard) G Adjustment Substitute Knob (standard) K T-bar T*2) Drain Substitute Manual (standard) Q Auto drain (standard) A Bowl Substitute Metal with liquid indicator D Transparent with guard (standard) P Gauge Substitute With integrated gauge (standard) G Without integrated gauge but with gauge port 1/8” N Pressure range *3) Substitute 0.3 to 4 bar F 0.3 to 10 bar (standard) M 0.7 to 17 bar S*2) Element Substitute 40 μm (standard) 3 5 μm 1 Flow characteristics Inlet pressure: 10 bar (145 psi) Port size: 1/4” , 5 µm element Inlet pressure: 10 bar (145 psi) Port size: 1/4” , 40 µm element Inlet pressure: 10 bar (145 psi) Port size: 3/8” , 5 µm element Inlet pressure: 10 bar (145 psi) Port size: 3/8” , 40 µm element Outlet pressure (bar) Outlet pressure (bar) Outlet pressure (bar) Outlet pressure (bar) Air flow (dm3/s) Air flow (dm3/s) Air flow (dm3/s) Air flow (dm3/s)

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltd en 8.105.350.03 Accessories Quikclamp® Page 6 820014-51KIT Quikclamp® with bracket assembled Page 6 820014-52KIT Neck mounting bracket and panel nut Page 7 820068-51KIT Panel mounting nut Page 7 820048-89KIT Integrated gauge 10 bar gauge 820073-01KIT Integrated gauge 20 bar gauge 820073-02KIT Integrated gauge 4 bar gauge 820073-03KIT Gauge adaptor kit 1/8 PTF 820100-01KIT Gauge adaptor kit R 1/8 820100-02KIT Port Adaptors Page 8 1/4 PTF 820015-02KIT 3/8 PTF 820015-03KIT G1/4 820015-08KIT G3/8 820015-09KIT Gauges (For regulators with gauge port instead of integrated port ) Center back connection, white face (for full technical specification see datasheet 8.900.900) Pressure range (bar)*3) (MPa) (psi) ø Thread size Model Mounting bracket Page 7 820024-50KIT Pressure sensing block 1/4 PTF Page 7 820016-50KIT Pressure sensing block G1/4 Page 7 820016-51KIT Padlock 840055-01KIT Lockout device 840055-02KIT Porting block 3/8” PTF Page 7 820028-50KIT Porting block G3/8 Page 7 820028-53KIT Pressure switch interface block (18D pressure switch) G1/4 Page 8 0523109000000000 Pressure switch 18D (0,5 ... 8bar) *1 Page 8 0881300 Digital pressure switch Page 8 0860810 *1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385 *3) primary scale

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltden 8.105.350.04 Maintenance/Service Filter cartridge 5 micron 820038-50KIT Filter cartridge 40 micron 820038-51KIT Auto drain kit with metal Nut - Imperial 6000-61KIT Auto drain kit with metal Nut - Metric 6000-60KIT Spare parts Filter Bowl (Guarded Poly bowl with auto drain 6 mm PIF) 820025-51KIT Filter Bowl (Guarded Poly bowl with manual drain) 820025-50KIT Filter Bowl (Metal with S/ Glass & auto drain, 6 mm PIF) 820003-51KIT Filter Bowl (Metal with S/ Glass & manual drain) 820003-50KIT Filter Bowl (Guarded Poly bowl with auto drain, 1/4 PIF) 820025-53KIT Filter Bowl (Metal with S/ Glass & auto drain, 1/4 PIF) 820003-56KIT R82 / B82 Elastomer Kit FRLB82-KIT

46,5 182 46,5 46,5 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltd en 8.105.350.05 Dimensions Dimensions in mm Projection/First angle # Minimum clearance for bowl removal

1 Main ports 1/4” , 3/8” (ISO G/PTF)

2 Gauge port Rc 1/8 for ISO G and

1/8 PTF for PTF main ports Automatic Drain1/4 Turn Manual Drain T-bar adjustment

Ø Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltden 8.105.350.06 Dimensions in mm Projection/First angleAccessories Quikclamp® with wall bracket Quikclamp® Neck mounting bracket Panel mounting nut Universal Mounting bracket Recommended panel hole size: ø 36.25 … 36.75 mm Panel thickness: up to 4mm

18 A/C

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltd en 8.105.350.07 Dimensions in mm Projection/First angle Pressure sensing block Full flow porting block Porting block for 18D pressure switch 18D Pressure switch 18D Porting block and 18D assembled Pipe adaptor

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2017 - 9217b) © 2020 Norgren Ltden 8.105.350.08 51D Pressure switch - digital Dimensions in mm Projection/First angle

1 Switch OUT 1, green LED

2 Switch OUT 2, red LED

3 Dustproof protector

4 Connector M12 x 1

5 Inlet port

6 Alternative inlet port G1/8 plugged

7 Thread for mounting screw

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/ data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. EN - Englisch