8175409 FESTO | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Part number: 8175409 General operating condition Data sheet Feature Value Dimensions W x L x H 50.1 mm x 107.3 mm x 57.5 mm Width dimension 50.1 mm Type of mounting Screwed tightly Product weight 93 g Mounting position Any Ambient temperature -20 °C ... 50 °C Note on ambient temperature Observe ambient temperature derating according to IEC 61131-2:2017 Storage temperature -20 °C ... 70 °C Relative air humidity 5 - 95 % Non-condensing Nominal altitude of use above sea level <= 2000 m ASL (> 79.5 kPa) Max. installation height 3500 m Information on max. installation height Observe ambient temperature derating according to IEC 61131-2:2017 Corrosion resistance class (CRC) 1 - Low corrosion stress Vibration resistance Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 Note on vibration resistance SG1 on H-rail SG2 on direct mounting Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6 Shock resistance Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 Note on shock resistance 30 g/11 ms as per EN 60068-2-27 SG1 on H-rail SG2 on direct mounting Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27 Protection class III Contamination level 2 Overvoltage category II Max. cable length 30 m outputs LABS (PWIS) conformity VDMA24364-B2-L Material fire test UL94 V-0 (housing) Note on materials RoHS-compliant Halogen-free Free of phosphoric acid ester Cover material PBT-reinforced Material of screws Steel, nickel-plated O-ring material FPM 3/17/26 - Subject to change - Festo SE & Co. KG 1/2

Diagnostics via LED Diagnostics per channel Diagnostics per module Load power supply Status per channel Diagnose per internal communication Communication error Short-circuit/overload in output signal Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage Max. address capacity outputs 1 byte No. of outputs 8 Module parameters Configuration of voltage monitoring, load supply PL Behavior after short circuit/overload at the output Communication interface, protocol AP Note regarding operating voltage SELV/PELV fixed power supplies required Note voltage drop Note on nominal operating voltage DC Protected Extra-Low-Voltage as per IEC 60204-1 Nominal operating voltage DC load 24 V Permissible voltage fluctuations load ± 25 % Nominal operating voltage DC for electronics/sensors 24 V Permissible voltage fluctuations for electronics/sensors ± 25 % Intrinsic current consumption at nominal operating voltage for electronics/sensors typically 25 mA Intrinsic current consumption at nominal operating voltage load Typically 5 mA Power failure buffering 10 ms Potential separation between the supply voltages electronics/sensor technology and load/valves yes Reverse polarity protection yes Electrical connection output, function Digital output Electrical connection output, connection type 4x socket Electrical connection output, connection technology M12x1 A-coded as per EN 61076-2-101 Electrical output connection, number of pins/wires 5 Electrical connection for output, connection pattern 00995384 Characteristic curve outputs as per IEC 61131-2, type 2 Switching logic at outputs PNP (positive switching) Fuse protection outputs (short circuit) Internal electronic fuse per channel Behavior after end of overload of the outputs No automatic return Output delay with resistive load Signal change 0->1: < 200 µs Signal change 1->0: < 200 µs Max. residual current of outputs per module 9 A Electrical isolation of outputs between channels no Electrical isolation of outputs between channel - internal communication yes Max. power supply per channel 2 A 3/17/26 - Subject to change - Festo SE & Co. KG 2/2