Features
/C0068Maximum Rating: 5 Amps, 250 Volts /C0068Typical Operating Temperature Tolerance +1−2°C /C0068Full 2 3/4” leads to fit all replacement configurations /C0068All types meet the requirements of Underwriters Laboratories Specifications and CUL /C0068RoHS Compliant Characteristics NTE Type No. Diag. No. Functioning Temperature Holding Temperature Maximum Temperature °C °F °C °F °C °F 8000 729 76 168 53 127 200 392 8005 729 86 187 61 142 200 392 8010 729 102 216 77 171 200 392 8015 729 115 239 89 192 200 392 8020 729 130 266 103 217 200 392 8025 729 136 277 111 232 200 392 8030 729 145 293 118 244 200 392 8035 729 150 302 123 253 200 392 Diagram 729 2.756 (70.0) .276 (7.0) .031 (0.8) .135 (3.44) Note 1. Temperature sensitive devices. Do not store above +48°C (+120°F). Note 2. With proper air flow, heat generation below 5 Amps is minimal, above 5 Amps the upper limit on the currentcapac- ity will depend on the environment for each specific application. Note 3. A general rule of thumb for continuous operating temperature for thermal cut−offs is 30°C less than the Maximum Opening Temperature.