80010728 KATHREIN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 10
Technical content
80010728 Page 1 of 4
8-Port Antenna 1710–2170/1710–2170/2490–2690/2490–2690 65°/65°/60°/60° Type No. 80010728 B1, connector 1–2 Y1, connector 5–6 1710–2170 2490–2690 Frequency Range MHz 1710 – 1880 1850 – 1990 1920 – 2170 2490 – 2690 Gain at mid Tilt dBi 17.3 17.8 17.8 18.1 Horizontal Pattern: Azimuth Beamwidth ° 67 ± 3.1 64 ± 2.4 63 ± 3.1 56 ± 3.7 Front-to-Back Ratio, Total Power, ± 30° dB > 26 > 26 > 26 > 24 Cross Polar Discrimination at Boresight dB > 22 > 22 > 22 > 25 Cross Polar Discrimination over Sector dB > 13.5 > 12.5 > 10.5 > 9.5 Azimuth Beam Port-to-Port Tracking dB < 1.5 < 1.5 < 1.0 < 1.0 Vertical Pattern: Electrical Downtilt continuously adjustable ° 2.0 – 11.0 2.0 – 14.0 Tilt Accuracy ° < 0.3 < 0.3 < 0.3 < 0.2 First Upper Side Lobe Suppression dB > 18 > 18 > 17 > 16 Upper Side Lobe Suppr ession, 20° Sector above Main Beam dB > 16 > 17 > 17 > 16 Cr oss Polar Isolation dB > 28 > 28 Port to Port Isolation dB > 30 (B1 // B2, Y1, Y2) > 30 (Y1 // B1, B2, Y2) Max. Effective Power per Port W 200 (at 50 °C ambient temperature) Max. Effective Power Port 1–2 + Port 5–6 W 400 (at 50 °C ambient temperature) Values based on NGMN-P-BASTA (version 9.6) requirements. 8-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by 1710–21701710–2170 2490–2690 2490–2690 XX X X 65°65° 60° 60° B2B1 Y1 Y2 Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
B2, connector 3–4 Y2, connector 7–8 1710–2170 2490–2690 Frequency Range MHz 1710 – 1880 1850 – 1990 1920 – 2170 2490 – 2690 Gain at mid Tilt dBi 17.3 17.8 17.8 17.9 Horizontal Pattern: Azimuth Beamwidth ° 67 ± 3.8 64 ± 2.3 63 ± 3.1 56 ± 3.5 Front-to-Back Ratio, Total Power, ± 30° dB > 25 > 26 > 26 > 23 Cross Polar Discrimination at Boresight dB > 21 > 21 > 21 > 23 Cross Polar Discrimination over Sector dB > 14.5 > 12.0 > 11.0 > 9.0 Azimuth Beam Port-to-Port Tracking dB < 1.5 < 1.0 < 0.5 < 1.5 Vertical Pattern: Electrical Downtilt continuously adjustable ° 2.0 – 11.0 2.0 – 14.0 Tilt Accuracy ° < 0.3 < 0.3 < 0.3 < 0.3 First Upper Side Lobe Suppression dB > 17 > 17 > 16 > 16 Upper Side Lobe Suppr ession, 20° Sector above Main Beam dB > 16 > 17 > 16 > 16 Cr oss Polar Isolation dB > 28 > 28 Port to Port Isolation dB > 30 (B2 // B1, Y1, Y2) > 30 (Y2 // B1, B2, Y1) Max. Effective Power per Port W 200 (at 50 °C ambient temperature) Max. Effective Power Port 3–4 + Port 7–8 W 400 (at 50 °C ambient temperature) Values based on NGMN-P-BASTA (version 9.6) requirements. Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
80010728 Page 3 of 4
Electrical specifications, all systems Impedance Ω 50 VSWR < 1.5 Return Loss dB > 14 Interband Isolation dB > 30 Passive Intermodulation dBc < –150 (2 x 43 dBm carrier) Polarization ° +45, –45 Max. Effective Power for the Antenna W 700 (at 50 °C ambient temperature) Values based on NGMN-P-BASTA (version 9.6) requirements. Mechanical specifications Input 8 x 7-16 female Connector Position bottom Adjustment Mechanism FlexRET, continuously adjustable Wind load (at Rated Wind Speed: 150 km/h) N | lbf Frontal: 570 | 128 Maximal: 625 | 141 Max. Wind V elocity km/h mph 200 124 Height / Width / Depth mm inches 1471 / 275 / 103 57.9 / 10.8 / 4.1 Category of Mounting Hardware M (Medium) Weight kg lb 17.0 / 19.2 (clamps incl.) 37.5 / 42.3 (clamps incl.) Packing Size mm inches 1666 / 298 / 136 65.6 / 11.7 / 5.4 Scope of Supply Panel, FlexRET and 2 units of clamps for 42 –115 mm | 1.7–4.5 inches diameter 1496 | 58.9 1604 | 63.1 2)1) 1471 | 57.9 All dimensions in mm | inches 1) ∅ 9 | 0.4 2) 64 | 2.5 For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. Material: Reflector screen: Aluminum. Radiator: Tin-plated zinc. Flat fiberglass radome: The max. radome depth is only 103 mm | 4.0 inches. Fiber glass material guarantees optimum performance with r egards to stability, stiffness, UV resistance and painting. The color of the radome is grey. All screws and nuts: Stainless steel or hot-dip galvanized steel. Grounding: The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. Accessories (order separately if required) Type No. Description Remarks mm | inches Weight approx. kg | lb Units per antenna 731651 1 clamp Mast diameter: 28 – 85010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 2 85010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2 737978 1 downtilt kit Downtilt angle: 0° – 8° 2.3 | 5.1 1
86010154 Site Sharing Adapter 3-way (see figur
e below) 0.7 | 1.5 86010155 Site Sharing Adapter 6-way (see figure below) 1.4 | 3.1
86010162 Gender Adapter Solely to be used in combination with
the FlexRET module 86010153V01 0.045 | 0.099 1 86010163 Port Extender 0.16 | 0.35 1 Accessories (included in the scope of supply) 738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 2 86010153V01 FlexRET 1 Site Sharing Adapter 3-way FlexRET BTS1 BTS2 BTS3 FlexRET FlexRET AISG Site Sharing Adapter 6-way FlexRET BTS3 BTS4 FlexRET FlexRET BTS2BTS1 BTS5 BTS6 AISG Configuration example with Site Sharing Adapter 86010154 Configuration example with Site Sharing Adapter 86010155 For more information please refer to the respective data sheets. Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
Any previous data sheet issues have now become invalid. Page 4 of 4 80010728 8-Port Antenna B2 B2 8 7 4 3Left Right Y1(L) / Y2(R) 2490 - 2690 B1(L) / B2(R) 1710 - 2170 123 | 4.8 120 | 4.7 220 | 8.7 47.5 | 1.9 275 | 10.8 * 103 | 4.0 * Bottom view * Dimensions refer to radome All dimensions in mm | inches Layout of interface: Left Right Correlation Table Frequency range Band Connector 1710–2170 MHz B1 1–2 1710–2170 MHz B2 3–4 2490–2690 MHz Y1 5–6 2490–2690 MHz Y2 7–8 Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
conditions: Kathr ein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with r egard to the following items: – Low temperature: –55 °C – High temperature (dry): +60 °C For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to operate under the environmental conditions as described in the valid data sheet of the FlexRET. Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions. Envir onmental tests: Kathrein antennas fulfil the stated specifications after completion of the environmental tests as defined in ETS 300 019-2-4. The homogenous design of Kathrein’ s antenna families uses identical modules and materials. Extensive tests have been performed on typical samples and modules. The vibration test has been adapted relating to frequency and acceleration to the conditions of mast mounted antennas. Please note: As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions. The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4. Wind loads are calculated according to DIN 1055-4. The antennas may be used at locations where the anticipated peak wind velocity or gust wind speed lies within the maximum wind speed listed in the data sheet. W e warrant the mechanical safety and electrical functionality under such conditions. The wind speeds are defined in accordance with the DIN, EN or TIA standar ds. This warranty makes allowance for the partial safety factors specified in those standards. Extraor dinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structur es), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning pr ocess. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. Site planning and installation must be carried out by qualified and experienced staff. All r elevant national safety regulations must be upheld and respected. Incorrect site planning, faulty installation, as well as interfering surroundings on site, may lead to deviations in the electrical parameters compared to those specified in the respective data sheets. The connectors on this pr oduct are only suitable for connecting to the compatible counterpart. Please ensure that the connected cable has been fitted with a connector of the same standard, otherwise damage may occur The tilt values will be set to any arbitrary value in the given tilt range. These values are independent from the frequency band or antenna type and can vary between antennas and bands. EU-RED Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.kathrein.com Page 1 of 1 936.4694/d Subject to alteration. General Information about Panel Antennas Our products are compliant to the EU Directive RoHS as well as to other environmentally relevant regulations (e.g. REACH). RoHSOur quality assurance system and our environmental management system apply to the entire company and are certified by TÜV according to EN ISO 9001 and EN ISO 14001. Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
Type No. 86010153V01 Protocols compliant to 3GPP/AISG 2.0 Logical interface ex factory 3GPP/AISG 2.0 Operates as Single RETs or Multi RET Ex factory Single RETs Input voltage range V 10 ... 30 (pin 6) Power consumption W Typically < 1; < 10 (motor activated) Connectors 2 x 8 pin connector according to IEC 60130-9; according to AISG-C 485 Daisy chain in: male; Daisy chain out: female Hardware interfaces RS 485A/B (pin 5, pin 3); power supply (pin 6); DC return (pin 7); according to AISG / 3GPP Adjustment time (full range) sec 40 (typically, depending on antenna type) Adjustment cycles > 50,000 Temperature range °C –40 … +60 Protection class IP 24 (installed) Lightning protection AISG interface (each pin) 2.5 kA (10/350 µs) 8 kA (8/20 µs) according to IEC 61000-4-5 Housing material Profile: Aluminum anodized; cover: Aluminum die cast coated Weight g lb 350 0.77 Packing size (H x W x D) mm inches 245 x 93 x 102 9.6 x 3.6 x 4 Dimensions (H x W x D) mm inches 142 x 71 x 51 5.6 x 2.8 x 2 Please note: If the Primary which controls the FlexRET system does not support the default ex-factory interface setting, then the FlexRET must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information. If the FlexRET of an antenna has to be replaced, the FlexRET gets the information stored in the antenna after power on automatically. It is not necessary to configure the FlexRET manually. Standards: EN 60950-1 (Safety) EN 60950-22 (Safety – Equipment installed outdoor) EN 55022 (Emission) EN 55024 (Immunity) ETS 300019-1-4 (Environmental) UL 60950-1; 1 st edition Certification: CE, FCC Scope of supply: FlexRET Optional: Site Sharing Adapter (86010154 or 86010155) to create independent logical interfaces at one antenna or site. Makes it possible to operate with mor e than one independent Node B. Gender Adapter (86010162) to convert the AISG out (female) to an AISG in (male) port in order to operate one FlexRet with exactly 2 BTS. Detailed information is given in the data sheet of the Gender Adapter. Port Extender (86010163) to convert the existing AISG input and output in order to operate FlexRet with exactly 2 BTS while maintaining the daisy chain capability. Detailed information is given in the data sheet of the Port Extender. Please note: In general, the addressing of the FlexRET is automatically performed. Only in case the FlexRET is manually addressed, the serial number has to be extended by the corresponding colour coding extension (e.g. CSG351234-R1 ). The respective information can be found on the site documentation which is included in the scope of supply. 86010153V01 Page 1 of 4 936.5204/b Subject to alteration. FlexRET A flexible, integrated solution for adjusting the electrical downtilt of Kathrein FlexRET antennas.
- Compliant to 3GPP/AISG 2.0 • Daisy Chain feasibility
- Single RETs or Multi RET displayed • Pre-configured
- Two way antenna sharing feasibility Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
936.5204/b Subject to alteration. FlexRET Startup of FlexRET The FlexRET module included in the antenna is preconfigured with the following information: Antenna model no., Antenna Serial no., Antenna configuration data. After connecting a control cable and scanning the antenna line devices (ALD) the used primary (e.g. NodeB, ALC, etc.) will find the FlexRET. You only need to insert your additional data. Connecting the control cables: Connect a control cable to the daisy chain input of the FlexRET. The tightening torque for fixing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The connector should be tightened by hand or by a special torque screw driver (order no. 85010080). See also data sheet for Kathrein AISG-cable (86010007, ...). Please note: To ensure the tightness of the RET System, Kathrein recommend the use of Kathrein components only. Please note: If the daisy chain output is not used, do not remove the protection cap. For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent FlexRET or external RCU. Please note: Do not remove the protection cap on the daisy chain output of the last FlexRET or RCU device. Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
936.5204/b Subject to alteration. FCC – Statements FCC Statements FCC 15.19 This device complies with Part of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC 15.105 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit di fferent from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Canada CNR-‐Gen Section 7.1.3 This device complies with Industry Canada licence -‐exempt RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ICES-‐003 This Class B digital apparatus complies with Canadian ICES -‐003. Cet appareil numérique de la classe B est conforme à la norme NMB -‐003 du Canada. FCC 15.21 (Warning Statement) [Any] changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
936.5204/b Subject to alteration. FCC – Statements Compliance Information Statement (Declaration of Conformity Procedure) Model Name: FlexRET FCC ID SP3-86010153 EU-RED Hereby, Kathrein Werke KG declares that the radio equipment type 86010153V01 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.kathrein.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Responsible Party: Kathrein USA Address: Greenway Plaza II 2400 Lakeside Blvd. Suite 650 Richardson, Texas 75082 Telephone: (01+) 214.238.8800 Type of equipment:
738546 Page 1 of 1
Clamp Included in the Scope of Supply 936.3920/c Subject to alteration. Suitable for mast diameter (mm) [inches] 42 – 115 [1.65 – 4.53] Antenna – mast distance (mm) [inches] 20 – 25 [0.79 – 0.98] Material of clamp and screws Hot-dip galvanized steel / stainless steel Weight (kg) [lb] 1.1 [2.43] Please note: Kathrein does not recommend to use counter nuts. The additional nuts supplied are only meant as spares. All dimensions in mm and [inches] 152 [5.98] 100 [3.94] 40 [1.57] 72 [2.83] 35 [1.38] 64 [2.52] 125 [4.92] 40 [1.57] 20–25 [0.79–0.98] 42–115 [1.65–4.53] M10 MA = 25 Nm M8 MA = 20 Nm 20–25 [0.79–0.98] Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com