PXIE-LCR5100 NI | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 32
Technical content
PXIe-LCR5100 BundleExpandable PXI bundle based on PXIe-4190 LCR Meter and SMU, 2 MHz, +/-40 V SpecificationsPXIe-1083 and PXIe-4190
PXI LCR BundleIn the BoxPXIe-LCR5100 BundleBundle P/N: 867113-01 Recommended Software Table of ContentsThis document combines the PDFs of this bundle together. The page numbers in the table of contents correspond to the page number of PDF the component’s documentation begins.PXIe-1083 Specifications………………………………………………………………………….PXIe-4190 Specifications…………………………………………………………………………. Test WorkflowP/N: 788509-35 Test Workflow is a bundle of select NI software featuring engineering-specific tools that help test professionals accomplish anything from their day-to-day work to overcoming their most challenging obstacles.Test Workflow includes:•LabVIEW -a graphical programming environment engineers use to develop automated research, validation, and production test systems.•InstrumentStudio-an application software that provides an integrated approach to interactive PXI measurements.•TestStand-a test executive software that accelerates system development and deployment for engineers in validation and production.•And more NI Software! 316 PXIe-4190(LCR Meter)PXIe-1083(5-Slot PXIe Chassis) Accessories:•DSUB to BNC cable •Thunderbolt cable•Power cable, US
This document contains specifications for the PXIe-1083 chassis. Electrical The following section provides information about the PXIe-1083 AC input and DC output. AC Input Input rating 100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A Operating voltage range1 90 VAC to 264 VAC Nominal input frequency 50 Hz/60 Hz Operating frequency range1 47 Hz to 63 Hz Efficiency 78% typical Over-current protection Internal fuse in line Main power disconnect The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane. Caution Disconnect power cord to completely remove power. © National Instruments 3 PXIe-1083 Specifications
DC output characteristics of the PXIe-1083. Maximum total available power for the PXIe-1083 is 293 W. The maximum combined power available on +3.3 V and +5 V is 180 W. The maximum power available for each Thunderbolt port is 15 W (5 V/3 A). Table 1. Backplane Slot Current Capacity Note PCI V(I/O) pins in Hybrid Peripheral Slots are connected to +5 V. temperature considerations at 58 W.
Module cooling Forced air circulation (positive pressurization) through one 150 CFM fan Module slot airflow direction Bottom of module to top of module Module intake Bottom of chassis Module exhaust Top, right side of chassis Slot cooling capacity 58 W; slot 6 supports 58 W cooling with high fan mode Power supply cooling Forced air circulation through integrated fans Power supply intake Front and left side chassis Power supply exhaust Rear of chassis Minimum chassis cooling clearances Above 44.45 mm (1.75 in.) Rear 44.45 mm (1.75 in.) Sides 44.45 mm (1.75 in.) Below Rack 44.45 mm (1.75 in.) Desktop 25.4 mm (1.00 in.) © National Instruments 5 PXIe-1083 Specifications
Maximum altitude 2,000 m (6,560 ft.), 800 mbar (at 25 °C ambient, high fan mode) Pollution Degree 2 Indoor use only. Operating Environment Ambient temperature range When all peripheral modules require ≤38 W cooling capacity per slot 0 °C to 50 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and high temperature limit. When any peripheral module requires >38 W cooling capacity per slot 0 °C to 40 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and MIL- PRF-28800F Class 4 high temperature limit. Relative humidity range 20% to 80%, noncondensing Storage Environment Ambient temperature range –40 °C to 71 °C (IEC-60068-2-1 and IEC-60068-2-2.)[3] Meets MIL- PRF-28800F Class 3 limits. Relative humidity range 10% to 95%, noncondensing ni.com6 PXIe-1083 Specifications
Operational shock 30 g peak, half-sine, 11 ms pulse (IEC-60068-2-27.)3 Meets MIL- PRF-28800F Class 2 limits. Operational random vibration 5 to 500 Hz, 0.3 grms Non-operating vibration 5 to 500 Hz, 2.4 grms (IEC 60068-2-64.)3 Non-operating test profile exceeds the requirements of MIL-PRF-28800F, Class 3. Acoustic Emissions Sound Pressure Level (at Operator Position) (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)
38 W Profile
Auto fan (up to 30 °C ambient) 33.7 dBA High fan 50.8 dBA
58 W Profile
Auto fan (up to 30 °C ambient) 54.7 dBA High fan 55.3 dBA Sound Power Level © National Instruments 7 PXIe-1083 Specifications
Auto fan (up to 30 °C ambient) 44.9 dBA High fan 60.3 dBA Auto fan (up to 30 °C ambient) 63.4 dBA High fan 64.2 dBA Note The protection provided by the PXIe-1083 can be impaired if it is used in a manner not described in this document. Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ IEC 61010-1, EN 61010-1 ■ UL 61010-1, CSA C22.2 No. 61010-1 Note For safety certifications, refer to the product label or the Product Certifications and Declarations section. EMC Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. ni.com8 PXIe-1083 Specifications
This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory rules. EMC Notices Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section. Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local regulatory rules. Notice Operate this product only with shielded cables and accessories. Electromagnetic Compatibility Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions © National Instruments 9 PXIe-1083 Specifications
■ AS/NZS CISPR 11: Group 1, Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In Europe, Canada, Australia, and New Zealand (per CISPR 11) Class A equipment is intended for use in nonresidential locations. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: ■ 2014/35/EU; Low-Voltage Directive (safety) ■ 2014/30/EU; Electromagnetic Compatibility Directive (EMC) ■ 2011/65/EU; Restriction of Hazardous Substances (RoHS) Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental ni.com10 PXIe-1083 Specifications
regulations and directives with which NI complies, as well as other environmental information not included in this document. EU and UK Customers
- Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/ environment/weee. 电子信息产品污染控制管理办法(中国 RoHS)
- 5 40e 中国 RoHS— NI 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/ rohs_china。(For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) Backplane Size 3U-sized; 5 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. Backplane bare-board material UL 94 V-0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated System Synchronization Clocks
10 MHz System Reference Clock: PXI_CLK10
© National Instruments 11 PXIe-1083 Specifications
Maximum slot-to-slot skew 250 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 5 ps RMS phase-jitter (10 Hz–1 MHz range) Duty-factor 45% to 55% Unloaded signal swing 3.3 V ±0.3 V Note For other specifications, refer to the PXI-1 Hardware Specification.
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to-slot skew 100 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) Duty-factor for PXIe_CLK100 45% to 55% Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) 400 mV to 1000 mV Note For other specifications, refer to the PXI-5 PXI Express Hardware Specification. ni.com12 PXIe-1083 Specifications
for installing the optional rack mount kits. Figure 1. PXIe-1083 Chassis Dimensions (Front)
Figure 2. PXIe-1083 Chassis Dimensions (Side) Figure 3. PXIe-1083 Chassis Dimensions (Bottom) 1 The operating range is guaranteed by design.
2 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use.
3 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use. © 2022 National Instruments Corporation.
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty. ■ Typical specifications describe the performance met by a majority of models. ■ Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing. Specifications are Warranted unless otherwise noted. SMU Specifications SMU Specifications Conditions The following conditions must be met when operating in SMU Mode. ■ Ambient temperature[1] of 23 °C ± 5 ºC ■ Relative humidity between 10% and 60%, noncondensing ■ Chassis with slot cooling capacity ≥58 W ■ Calibration interval of 1 year ■ 30 minutes warm-up time ■ Self-calibration performed within the last 24 hours ■ NI-DCPower 21.8 or later installed ■ Connections between force and sense leads are required and must be made while the niDCPower Output Enabled or niDCPower Output Connected properties are set to FALSE[2] © National Instruments 3 PXIe-4190 Specifications
■ niDCPower Aperture Time property or NIDCPOWER_ATTR_APERTURE_TIME attribute set to 2 power-line cycles (PLC) ■ niDCPower Cable Length property or NIDCPOWER_ATTR_CABLE_LENGTH attribute set when using the lower two current ranges SMU Instrument Capabilities DC voltage ranges 1 V 10 V 40 V DC current ranges 1 nA 100 nA 1 µA 10 µA 100 µA 1 mA 10 mA 100 mA Available DC output power Sourcing 4 W Sinking 4 W ni.com4 PXIe-4190 Specifications
Figure 1. PXIe-4190 Quadrant Diagram Table 1. Voltage Programming and Measurement Accuracy/Resolution
Table 2. Current Programming and Measurement Accuracy/Resolution
10 Hz, peak-to-
SMU Guard Output Characteristics Cable guard Output impedance <100 mΩ, nominal Offset voltage 1 mV, typical SMU Measurement and Update Timing Available sample rates[9] (600 kS/s)/N, nominal where ■ S is samples Sample rate accuracy Equal to PXIe_CLK100 accuracy, nominal Maximum measure rate to host 600 kS/s, nominal Input trigger to Source event delay 10 µs nominal Source event jitter 2 µs pk-pk, nominal Measure event jitter 2 µs pk-pk, nominal
1 The ambient temperature of a PXI system is defined as the temperature at the
chassis fan inlet (air intake).
2 Disconnecting the sense leads while both these properties are set to TRUE may
result in output protection errors or long settling tails due to the feedback path for the control loop being open. If the PXIe-4190 is run open loop due to accidental sense lead disconnection, allow a minimum of 1 minute after establishing proper lead connections before making measurements. 3 Temperature coefficient applies beyond 23 °C ±5 °C ambient within ±5 °C of Tcal. © National Instruments 7 PXIe-4190 Specifications
4 Tcal is the internal device temperature recorded by the PXIe-4190 at the
completion of the last self-calibration 5 Temperature coefficient applies beyond 23 °C ±5 °C ambient within ±5 °C Tcal. 6 Under the following additional conditions: with 10 PLC, and 11-point median filter. 7 Under default specification conditions. 8 10 Hz to 20 MHz bandwidth, PXIe-4190 configured for normal transient response.
9 When source-measuring, both the NI-DCPower Source Delay and Aperture Time
properties affect the sampling rate. When taking a measure record, only the Aperture Time property affects the sampling rate. LCR Specifications LCR Specifications Conditions The following conditions must be met when operating in LCR Mode. ■ Ambient temperature[1] of 23 °C ± 5 ºC ■ Relative humidity between 10% and 60%, noncondensing ■ Chassis with slot cooling capacity ≥58 W ■ Calibration interval of 1 year ■ 30 minutes warm-up time ■ Self-calibration performed within the last 24 hours ■ NI-DCPower 21.8 or later installed ■ Automatic Level Control (ALC) is On ■ LCR Measurement Time is Long unless otherwise stated ■ Open and short compensation has been completed ■ Connections between force and sense leads are required and must be made while the niDCPower Output Enabled or niDCPower Output Connected properties are set to FALSE[2] ■ Four-terminal pair (4TP) connections to load[3] ■ niDCPower Cable Length property or NIDCPOWER_ATTR_CABLE_LENGTH attribute set ni.com8 PXIe-4190 Specifications
■ Impedance range is within 30% of DUT impedance ■ Excitation voltage is set to at least 70 mV RMS ■ Temperature is within ±5 °C of last self-calibration ■ DC bias is off ■ SHDB13W6-4BNCM-LL Cable, 1 m (NI part number 788280-01) LCR Instrument Capabilities Maximum AC voltage 7.07 V RMS Maximum AC current 70.7 mA RMS Maximum DC bias voltage range ±40 V, including peak test signal Maximum DC bias current range ±100 mA, including peak test signal Measurement times Short 1 ms Medium 10 ms Long 100 ms Custom User-defined Note Measurement times round to the nearest positive integer number of cycles of the stimulus frequency. LCR Measurements
- Z—Impedance
- Y—Admittance
- Ls—Inductance using series-equivalent circuit model
- Cs—Capacitance using series-equivalent circuit model
- Rs—Resistance using series-equivalent circuit model
- Lp—Inductance using parallel-equivalent circuit model © National Instruments 9 PXIe-4190 Specifications
- Cp—Capacitance using parallel-equivalent circuit model
- Rp—Resistance using parallel-equivalent circuit model
- D—Dissipation factor
- Q—Quality factor
- V DC—DC voltage measurement
- I DC—DC current measurement
- AC voltage—AC voltage magnitude and phase angle
- AC current—AC current magnitude and phase angle LCR Test Signal Voltage stimulus Maximum 7.07 V RMS Minimum 7.07 mV RMS Resolution <1 µV RMS Maximum current 70.7 mA RMS Accuracy (ALC on) ≤10 kHz ±0.2% 10 kHz to 2 MHz ±6% Current stimulus Maximum 70.7 mA RMS Minimum 707 nA RMS Resolution <100 pA RMS Maximum voltage 7.07 V RMS Accuracy (ALC on) ≤10 kHz ±0.2% 10 kHz to 2 MHz ±6% ni.com10 PXIe-4190 Specifications
Table 3. Absolute Impedance Magnitude Accuracy, 708 mV RMS to 7.07 V RMS
40 Hz to
100 Hz to
1 MHz to
2 MHz
Note: When on boundary, use lower adjacent value.
- Up to 640 kΩ impedance range.
† Up to 255 kΩ impedance range. ‡ Up to 130 kΩ impedance range. Table 4. Absolute Impedance Magnitude Accuracy, 150 mV RMS to 707 mV RMS Note: When on boundary, use lower adjacent value.
- Up to 640 kΩ impedance range.
† Up to 255 kΩ impedance range. ‡ Up to 130 kΩ impedance range. Table 5. Absolute Impedance Magnitude Accuracy Multiplier for Stimuli Below 150
mV RMS Stimulus Voltage table value times the respective multiplier. Table 6. Absolute Impedance Phase Accuracy, 708 mV RMS to 7.07 V RMS Stimulus Note: When on boundary, use lower adjacent value.
- Up to 640 kΩ impedance range.
† Up to 255 kΩ impedance range. ‡ Up to 130 kΩ impedance range. Table 7. Absolute Impedance Phase Accuracy, 150 mV RMS to 707 mV RMS Stimulus
Note: When on boundary, use lower adjacent value.
- Up to 640 kΩ impedance range.
† Up to 255 kΩ impedance range. ‡ Up to 130 kΩ impedance range. Table 8. Absolute Impedance Phase Accuracy Multiplier for Stimuli Below 150 mV
1 MΩ to 10
10 MΩ to
RMS Stimulus Voltage table value times the respective multiplier. chassis fan inlet (air intake). lead connections before making measurements. 3 Refer to the PXIe-4190 Getting Started for more information on 4TP connections.
Isolation voltage, any pin to earth ground 40 V DC, Measurement Category I, functional Note Pins are functionally isolated from chassis ground to prevent ground loops, but do not meet IEC 61010-1 for safety isolation. Note The PXIe-4190 contains an internal switch controlled by the niDCPower Isolation State property or the NIDCPOWER_ATTR_ISOLATION_STATE attribute that can connect the GUARD terminal to chassis ground and prevent the module output from floating. Isolation ratings only apply when this property/attribute is set to Isolated. Protection Absolute maximum voltage Output HI/Output LO/Sense HI/Sense LO to Output HI/Output LO/Sense HI/Sense LO ±42 V Output HI/Sense HI to GUARD/Isolated Shield ± 6 V GUARD/Isolated Shield to Chassis GND ±42 V Absolute maximum current All terminals ±150 mA Output channel protection Output HI to GUARD/Isolated Shield Overvoltage Automatic output disable Output LO to all terminals © National Instruments 15 PXIe-4190 Specifications
Overcurrent Automatic output disable Sense HI/Sense LO to all terminals Overcurrent Current limiter protects inputs up to absolute maximum voltage specification Overtemperature Automatic output disable Physical Characteristics Dimensions 3U, one-slot, PXI Express/CompactPCI Express module Weight 481 g (17.1 oz) Front panel connectors Custom 6 coaxial socket, 7 standard socket, mixed layout D-SUB, female Triggers Input triggers Types Start Source Sequence Advance Measure Sources (PXI trigger lines 0 to 7) Polarity Active high (not configurable) Minimum pulse width 100 ns Destinations[2] (PXI trigger lines 0 to 7) Polarity Active high (not configurable) Minimum pulse width 200 ns Output triggers (events) ni.com16 PXIe-4190 Specifications
Sequence Iteration Complete Sequence Engine Done Measure Complete Destinations (PXI trigger lines 0 to 7)[3] Polarity Active high (not configurable) Pulse width 230 ns Calibration Interval Recommended calibration interval 1 year Power Requirements +3.3 V 1.0 A +12 V 2.7 A Environmental Characteristics Temperature Operating 0 °C to 55 °C [4] Storage -40 °C to 71 °C Humidity Operating 10% RH to 90% RH, noncondensing [5] Storage 5% RH to 95% RH, noncondensing Pollution Degree 2 Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature) © National Instruments 17 PXIe-4190 Specifications
Operating vibration 5 Hz to 500 Hz, 0.3 g RMS Non-operating vibration 5 Hz to 500 Hz, 2.4 g RMS Operating shock 30 g, half-sine, 11 ms pulse
1 Pulse widths and logic levels are compliant with PXI Express Hardware
Specification Revision 1.0 ECN 1.
2 Input triggers can come from any source (PXI trigger or software trigger) and be
exported to any PXI trigger line. This allows for easier multi-board synchronization regardless of the trigger source.
3 Pulse widths and logic levels are compliant with PXI Express Hardware
Specification Revision 1.0 ECN 1. 4 Not all chassis can achieve this ambient temperature range. Refer to PXI chassis specifications to determine the ambient temperature ranges your chassis can achieve.
5 Accuracy specifications are only warranted for operating environments with
temperatures below 30 °C and relative humidity levels below 60%. When transitioning the product from a storage or operating environment with relative humidity above 60%, you should allow the product to stabilize in the lower humidity environment for several hours before using it. ni.com18 PXIe-4190 Specifications © 2022 National Instruments Corporation.