782482_V01 MURATA-PS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
KMP_782482C_B01 Page 1 of 3
782482 Series
ADM2482E/ADM2487E Compatible Converter Transformers www.murata-ps.com For full details go to www.murata-ps.com/rohs www.murata.com SELECTION GUIDE Order Code Nominal Input Voltage Nominal Output Voltage Isolation Voltage Turns Ratio Package StyleVV V DC 782482/33VC 3.3 3.3 4000 1CT:1.33CT DIL 782482/53VC 5.0 3.3 4000 1.14CT:1CT DIL CHARACTERISTICS Parameter Conditions 782482/33VC 782482/53VC UnitsMin. Max. Min. Max. Primary Inductance, LP 1 100kHz, 20mV 190 310 150 260 μH Leakage Inductance, LL 1 100kHz, 250mV 8 8 μH Interwinding Capacitance, CWW 100kHz, 250mV 8 8 pF Primary DC Resistance, RDC 1 <0.1VDC 600 600 mΩ Volt-time Product, Et2 5kHz, 5V 13 13 Vμs ABSOLUTE MAXIMUM RATINGS Operating free air temperature range -40°C to 85°C Storage temperature range -50°C to 125°C Isolation voltage (flash tested for 1 second) 4.0kVDC SOLDERING INFORMATION3 Peak wave solder temperature 260˚C for 10 seconds Pin finish Matte tin Specifications typical at TA = 25°C 1 L P, LL and RDC measured between pins 1-3. 2 Where pulse applied across pins 1 and 2. 3 For further information, please visit www.murata-ps.com/rohs TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Volt- age’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. All products in this series are 100% production tested at their stated isolation voltage. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal opera- tion?” For a part holding no specific agency approvals both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test volt- age represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function cor- rectly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-acces- sible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environ- ment. This series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does de- pend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We there- fore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recog- nised parts rated for better than functional isolation where the wire enamel insulation is always supple- mented by a further insulation system of physical spacing or barriers.
FEATURES
RoHS compliant Analog Devices ADM2482E/ADM2487E compatible 4.0kVDC isolation Industry-standard pinout UL 94 V-0 package materials Low profile Toroidal construction Fully encapsulated Industrial temperature range Surface mount versions available soon Recommended by Analog Devices, Inc. Backward compatible with Sn/Pb soldering systems
DESCRIPTION
The 782482 series of converter transformers are specifically designed for use with Analog Devices chipsets to provide isolated RS-485 and RS-422 interfaces. Carefully controlled turns ratios ensure consistent performance whilst a toroidal construction minimises EMI.
KMP_782482C_B01 Page 2 of 3 ADM2482E/ADM2487E Compatible Converter Transformers www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS RECOMMENDED FOOTPRINT DETAILS 3.44±0.50 (0.135±0.02) 6.35 (0.25) 9.14 (0.360) Max. 9.77 (0.385) Max. Primary Secondary 0.30(0.012) (0.40±0.016) 0.6 (0.024) 2.54 (0.1) 782482/33VC XYYWW 2.54 (0.10) 2.54 (0.10) -0.00 (0.000) Unless otherwise stated all dimensions in mm (inches) ± 0.25 (0.01). Unless otherwise stated all dimensions in mm (inches) ±0.25 (0.01). Package Weight 1.1g TYP . TUBE OUTLINE DIMENSIONS 0.60±0.15 (0.024±0.006) 4.00 (0.16) 5.20 (0.21) 10.65 - 11.65 (0.419 - 0.459) 12.95 (0.51) 3.80 (0.15) 15.70 (0.62) Unless otherwise stated all dimensions in mm (inches) ±0.25 (0.01). Tube length: 500±2 (19.7±0.08) Tube quantity: 50 Tube material: Antistatic coated clear PVC. TOP VIEW
KMP_782482C_B01 Page 3 of 3 ADM2482E/ADM2487E Compatible Converter Transformers www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2021 Murata Power Solutions (Milton Keynes) Ltd This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment ( automobiles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.