Features

The NI hig h-performance S Series DAQ devices have the same basic features of a typical multifunction device – eight digital I/O lines, two counter/timers, two analog outputs, RTSI or PXI trigger bus for multidevice synchronization, and PFI lines for software-controlled routing of timing and triggering signals. S Series devices exceed the analog input performance of traditional multiplexed devices with features including: S Series Multifunction DAQ 12 or 16-Bit, 1 to 10 MS/s, 4 Analog Inputs Analog Input Sampling Input Analog Max Output Output Digital Counter/ Family Bus Inputs Resolution (bits) Rate (MS/s) Range (V) Outputs Rate (MS/s) Range (V) I/O Timers Triggers NI 6120 PCI, PXI 4 16 13 ±0.2 to ±42 2 41 ±10 82 2, 24-bit Analog, digital NI 6115 PCI, PXI 4 12 10 ±0.2 to ±42 2 41 ±10 82 2, 24-bit Analog, digital NI 6110 PCI 4 12 5 ±0.2 to ±42 2 41 ±10 8 2, 24-bit Analog, digital NI 6111 PCI 2 12 5 ±0.2 to ±42 2 41 ±10 8 2, 24-bit Analog, digital 14 MS/s single channel; 2.5 MS/s on two channels 2Hardware-timed up to 10 MB/s 3800 kS/s with NI-DAQmx, 1 MS/s with additional download. Special conditions apply . Table 1. Channel, Speed, and Resolution Specifications Table 2. Special Features

  • 2 or 4 analog inputs; dedicated A/D converter per channel
  • 1 to 10 MS/s per channel maximum sample rate
  • Analog and digital triggering
  • AC or DC coupling
  • 8 input ranges from ±200 mV to ±42 V
  • 2 analog outputs at 4 MS/s single channel or 2.5 MS/s dual channel
  • 8 digital I/O lines (5 V TTL/CMOS)
  • Two 24-bit counter/timers
  • Measurement services that simplify configuration and measurements Operating Systems
  • Windows 2000/NT/XP
  • Mac OS X
  • Linux Recommended Software
  • LabVIEW 7.x or higher
  • LabWindows/CVI 7.x or higher
  • Measurement Studio 7.x or higher
  • Digital Waveform Editor
  • SignalExpress 1.x or higher Other Compatible Software
  • VI Logger 2.x or higher
  • Visual Studio .NET
  • Visual Basic, C/C++, and C# Measurement Services Software (included)1
  • NI-DAQmx driver software
  • Measurement & Automation Explorer configuration utility
  • VI Logger Lite data-logging software 1Mac OS X and Linux applications must use NI-DAQmx Base driver software. Calibration Certificate Available

dynamic accuracy for transient or frequency measurements. for signals with high frequencies and large amplitudes. applications only analyzing signals in the frequency domain. onboard FIFO, you can achieve reliable data transfers to 10 MB/s. measurements across multiple device analog input channels. when developing custom applications with your S Series devices. analyzer, or one of several other instruments with these toolkits. presentation tools required for sound and vibration applications.

  • Distortion, gain, phase, cross-talk, and dynamic range measurements
  • Octave analysis
  • Swept-sine analysis
  • Linear, exponential, and peak hold measurements
  • Baseband and zoom FFT, power, FFT, power spectral density (PSD)
  • Limit testing
  • Short-time Fourier transform and shock response spectrum
  • Weighting filters
  • System calibration
  • Waterfall/colormap display NI LabVIEW Signal Processing Toolkit This toolkit is a suite of software tools, example programs, and utilities for time-frequency analysis and digital filter design. The toolkit includes:
  • Wavelet and filter-bank design
  • Digital filter design of FIR and IIR filters
  • Joint time-frequency analysis (JTFA) with the Gabor spectrograph
  • High-frequency resolution model-based spectral estimation for small datasets S Series Multifunction DAQ 12 or 16-Bit, 1 to 10 MS/s, 4 Analog Inputs 2 National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com

Figure 1. Sound and Vibration Toolkit

convert your S Series device into a full-featured spectrum analyzer.

  • Measurements such as in-band power and adjacent-channel power
  • 3D spectrogram
  • Analog modulation and demodulation
  • I-Q data for digital demodulation
  • Highly optimized FFT processing High-Performance Data Throughput Using NI-DAQmx driver software and S Series, you can take full advantage of your PC’s throughput potential, which is useful in many applications including transient recording. Flexible Data Transfer With NI-DAQmx, you can choose where to accumulate data – on the onboard memory, PC RAM memory, or PC hard drive memory. Thus, you can balance your PC application requirements and stream-to-disk/memory capabilities. In any case, NI-DAQmx optimizes data transfers by using DMA (direct memory access) and transferring large chunks of data, while ensuring no data loss. Y ou can also choose the format of your data, further optimizing throughput. Choices include raw (binary), scaled, or the high-level waveform data type. Using these techniques, you can achieve rates of more than 40 MS/s s ustained o ver the PCI/PXI bus to hard drive (depending on the PC). Data Compaction With the release of NI-DAQmx 7.4 or later, data compaction is available f or st ream-to-disk applications. The NI-DAQmx compaction feature strips unused or unwanted bits of data from each sample taken from your S Series device before it is permanently recorded to hard disk. This is helpful because hard drives are typically the throughput bottleneck compared to the PCI/PXI bus and PC RAM memory read/write speed. Using data compression, users with standard hard drives can see up to 20 percent higher throughput when streaming-to-disk. Signal Conditioning With the release of NI-DAQmx 7.4 or later, all S Series devices are compatible with parallel-mode SCXI modules. SCXI is limited to 100 kS/s for 16-bit accuracy and 333 kS/s for 12-bit accuracy when used in multiplexed mode. However, in parallel mode, the sample rate is limited by the maximum scan rate of the data acquisition device. When SCXI is used in parallel mode with S Series, all channels are simultaneously sampled and the sampling r ate is limited by the S Series device, from 250 kS/s per channel to 10 MS/s per channel. Measurement Services Software National Instruments measurement services software, built around NI-DAQmx driver software, includes intuitive application programming interfaces, configuration tools, I/O assistants, and other tools designed to reduce system setup, configuration, and development time. Automatic Code Generation – DAQ Assistant is an interactive guide that helps you navigate through configuring, testing, and programming measurement tasks and automatically generates the necessary code for LabVIEW, LabWindows/CVI, or Measurement Studio. Cleaner Code Development – Basic and advanced software functions have been combined into one easy-to-use yet powerful set to help you build cleaner code and move from basic to advanced applications without replacing functions. High-Performance Driver Engine – NI-DAQmx delivers maximum I/O system throughput with a multithreaded driver. Test Panels – With the M easurement & Automation Explorer configuration utility, you can test all of your module functionality before you begin development. Scaled Channels – Easily scale your voltage data into the proper engineering units using the NI-DAQmx Measurement Ready virtual channels by choosing from a list of common sensors and signals or creating your own custom scale. Data-Logging Software – VI Logger Lite is configuration-based software designed specifically for data logging. Features include easy logging and viewing of data, data extraction to Microsoft Excel, and code generation in LabVIEW. LabVIEW Integration – All NI-DAQmx functions create the waveform data type, which carries acquired data and timing information directly into more than 400 LabVIEW built-in analysis routines for display of results in engineering units on a graph. NI-DAQmx Base Driver NI-DAQmx Base (available at ni.com/downloads) offers Mac OS X and Linux users a programming interface similar to NI-DAQmx. It includes ready-to-use LabVIEW VIs and C function features similar to those included in NI-DAQmx driver software. Model Description Channels SCXI-1520 Universal Strain Gage Input 8 SCXI-1125 Isolation Amplifier 8 SCXI-1141/2/3 8-Pole Lowpass Filters 8

Table 3. Most Popular Parallel-Mode SCXI Modules

Figure 2. NI 6120 and NI 6115 Har dware Block Diagram

5National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com S Series Multifunction DAQ 12 or 16-Bit, 1 to 10 MS/s, 4 Analog Inputs

1 Not available on PCI-6111

Digital I/O (8) Trigger Analog Trigger Circuitry Trigger Level DACs DAQ - STC Analog Input Timing/Control Analog Output Timing/ControlDigital I/O Trigger Counter/ Timing I/O RTSI Bus Interface DMA/ Interrupt Request Bus Interface Calibration DACs DAC FIFO Data (32) AI Control Address/Data Control Data (32) Analog Input Control EEPROM Control DMA Interface MIO Interface DAQ-STC Bus Interface Analog Output Control I/O Bus Interface Generic Bus Interface PCI Bus Interface MITE IRQ DMA AO Control ADC FIFO Address (5) Gain Amplifier ACH3+ ACH3- ACH2+ ACH2- ACH1+ ACH1- ACH0+ ACH0- Calibration Mux EEPROM Calibration DACs AI CH21 Mux AI CH0 Mux Voltage REF AI CH1 Mux AI CH31 Mux CH3 12-Bit ADC CH2 12-Bit ADC CH0 12-Bit ADC CH1 12-Bit ADC DAC0 DAC1 Figure 3. NI 6110 and 6111 Hardware Block Diagram Includes data acquisition driver software.

Ordering Information

S Series Multifunction DAQ 12 or 16-Bit, 1 to 10 MS/s, 4 Analog Inputs 6 National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com These specifications are typical for 25 °C unless otherwise noted. Analog Input Input Characteristics Number of channels ADC resolution ADC pipeline Maximum sampling rate Minimum sampling rate Input signal ranges Max working voltage for all analog input channels Overvoltage protection Input FIFO buffer Analog filter type Analog filter frequency (-3 dB) 1800 kS/s with NI-DAQmx, 1 MS/s with additional download. Special conditions apply. Analog Output Output Characteristics Resolution Max update rate Output FIFO buffer size Voltage Output Digital I/O Data transfers Transfer rate Input buffer size Output buffer size Timing I/O Number of channels Resolution Base clocks available Maximum source frequency Triggers Analog Trigger Purpose Level Resolution Bandwidth (-3 dB) Digital Trigger Purpose PXI Trigger Bus (PXI only) RTSI Bus (PCI only) Bus Interface Physical Dimensions (not including connectors) Specifications

7National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com S Series Multifunction DAQ Cables and Accessories Recommended Configurations SH68-68-EP Noise-Rejecting Shielded Cable The SH68-68-EP is a shielded 68-conductor cable terminated with two 68-pin female 0.050 series D-type connectors. It features individually shielded analog twisted pairs for reduced cross-talk with high-speed devices. R6868 Low-Cost, Ribbon Cable The R6868 is a 68-conductor flat ribbon cable terminated with two 68-pin female 0.050 series D-type connectors. BNC-2110 Noise-Rejecting BNC I/O Connector Block The BNC-2110 is a shielded connector block with signal-labeled BNC connectors for easy connectivity of your analog input, digital I/O, and counter/timer signals. TB-2705 Noise-Rejecting Front-Mount I/O Connector Block The TB-2705 is a scr ew terminal block for your PXI DAQ devices. It latches to the front of your PXI modules with locking screws and provides strain relief and easy access to your analog, digital, trigger, and counter/timer signals through screw terminals. SCB-68 Noise-Rejecting Shielded I/O Connector Block The SCB-68 is a shielded I/O connector block for rugged, very-low-noise signal termination for connecting 68-pin DAQ devices. Silk-screened component locations provide an easy addition of simple signal-conditioning circuitry for your analog input channels. It also includes a general-purpose breadboard area as well as an IC temperature sensor for cold-junction compensation in temperature measurements. CB-68LP and CB-68LPR Low-Cost I/O Connector Blocks The CB-68 and CB-68LP are low-cost termination accessories with 68 screw terminals for easy connector of field I/O signals to 68-pin DAQ devices. The connector blocks include standoffs for use on a desktop or for mounting in a custom panel. The CB-68LP has a vertical-mounted 68-pin connector. The CB-68-LPR has a right-angle mounted connector, and it is used with the CA-1000. BNC-2110 I/O Connector Block R6868 Ribbon Cable SH68-68-EP Shielded Cable SCB-68 Shielded I/O Connector Block TB-2705 Terminal Block CB-68LP and CB-68LPR I/O Connector Blocks I/O Configuration Accessory Cable BNC shielded BNC-2110 (777643-01) SH68-68-EP (184749-01) Front-mount shielded screw terminals (PXI only) TB-2705 (778241-01) – Noise-rejecting shielded screw terminals SCB-68 (776844-01) SH68-68-EP (184749-01) Low-cost unshielded screw terminals CB-68LPR (777145-02) R6868 (777643-01)

© 2005 National Instruments Corporation. All rights reserved. CVI, DAQ-STC, LabVIEW, Measurement Studio, MITE, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI-DAQ, R TSI, SCXI, and SignalExpr ess ar e trademarks of National Instr uments. Other pr oduct and company names listed are trademarks or trade names of their respective companies. A National Instr uments Alliance Par tner is a business entity independent fr om NI and has no agency , par tnership, or joint-ventur e relationship with NI. NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our P rofessional Services T eam is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and int egrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We o ffer d esign-in c onsulting and product integration assistance if you want t o use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry- leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. T o use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration so ftware specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and a dvance r eplacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. National Instruments • info@ni.com ni.com • (800) 813 3693 SERVICE NEEDS