Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27 Control Gate Valve with 3-position pneumatic actuator Sample picture This manual is valid for the valve ordering number(s): The fabrication number is indicated on each product as per the label below (or similar): made in Switzerland Fabrication No.: patented . . Fabrication number Explanation of symbols: Read declaration carefully before you start any other action! Keep body parts and objects away from the valve opening! Attention! Hot surfaces; do not touch! Product is in conformity with EC guidelines, if applicable! Loaded springs and/or air cushions are potential hazards! Disconnect electrical power and compressed air lines. Do not touch parts under voltage! Wear gloves! Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General Safety Instructions» carefully before you start any other action!

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27 Imprint: Manufacturer VAT Vakuumventile AG, CH-9469 Haag, Switzerland Website www.vatvalve.com Phone +41 81 771 61 61 Fax +41 81 771 48 30 Email CH@vatvalve.com Publisher VAT Vakuumventile AG, CH-9469 Haag, Switzerland Editor VAT Vakuumventile AG, CH-9469 Haag, Switzerland Print VAT Vakuumventile AG, CH-9469 Haag, Switzerland Copyright © VAT Vakuumventile AG 2008 No part of these Instructions may be reproduced in any way (photocopies, microfilms or any other reproduction processes) nor may it be manipulated with electronic systems, duplicated or distributed without written permission from VAT. Offenders are liable to pay damages. The original VAT firmware and updated state of the art versions of the VAT firmware are intended for use with VAT products. The VAT firmware contains a limited, time unlimited user license. The VAT firmware may not be used for purposes other than those intended nor is it permitted to make copies of the VAT firmware. In particular, it is strictly forbidden to give copies of the VAT firmware to other people. The use of trade names, brand names, trademarks, etc. in these Instructions does not entitle third parties to consider these names to be unprotected and to use them freely. This is in accordance with the meaning of the laws and acts covering brand names and trademarks.

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27 Contents:

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

1 Use of product

Use product for clean and dry indoor vacuum applications under the conditions indicated in chapter «Technical data» only! Other applications are only allowed with the written permission of VAT. Corrosive process gases may impact the performance of the product. Please contact VAT to assure that the product is compatible with the process gases used in your application.

1.1 Technical data

Pressure range DN 63 - 200: 1 x 10-8 mbar to 2 bar (abs) DN 250 - 400: to 1 bar (abs) Differential pressure on the closed gate DN 63 - 200: 2 bar in either direction DN 250 - 400: 1 bar in either direction Max. differential pressure at opening 30 mbar Admissible temperature: Valve < 150°C Actuator < 50°C Cycles until first service 200000 Supply voltage see label on solenoid control valve Power required 2 x 2,5 W Contact rating of position indicator 5 A / 250 V AC, 3 A / 50 V DC Compressed air pressure 4 - 7 bar / 56 -98 psi Further data according to VAT catalogue «Vacuum Valves 2008».

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

2 Installation

2.1 Installation into the system

The valve seat side is indicated by the symbol: on the connection flange.

2.2 Connections

2.2.1 Tightening torque for mounting screws on flanges

  1. Mounting with centering ring Tighten mounting screws of the flanges uniformly in crosswise order. Observe the maximum torque levels in the following table. Higher tightening torques deform the valve body and can lead to an improper function of the valve. DN max. tightening torque (Nm) max. tightening torque (lbs . ft) mm inch ISO-F JIS ASA-LP ISO-F JIS ASA-LP 63/100 4 8 – 10 8 – 10 8 – 10 6 – 8 6 – 8 6 – 8 160 6 13 – 15 13 – 15 20 – 30 9 – 11 9 – 11 15 – 22 200 8 13 – 15 13 – 15 20 – 30 9 – 11 9 – 11 15 – 22 250 10 17 – 20 17 – 20 40 – 60 13 – 15 13 – 15 30 – 44 320 350 14 17 – 20 17 – 20 40 – 60 13 – 15 13 – 15 30 – 44 400 16 17 – 20 30 – 35 55 – 80 13 – 15 22 – 26 41 – 59 2. Mounting with O-ring in groove Tighten mounting screws of the flanges uniformly in crosswise order. Observe the maximum torque according to the grade of screws and depth of thread you use.

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

2.2.2 Admissible forces

Forces from evacuating the system, from the weight of other components, and from baking can lead to deformation of the valve body and to malfunction of the valve. The stress has to be relieved by suitable means, e.g. bellows sections. The following forces are admissible: DN (nom. I.D.) Axial tensile or compressive force «FA» Bending moment «M» mm inch N lbf Nm lbf ft 63 21/2 1960 440 78 58 100 4 2450 560 98 72 160 6 2940 660 147 108 200 8 2940 660 147 108 250 10 3430 770 196 145 320 / 350 12 / 14 3920 880 294 217 400 16 7840 1760 980 722 If a combination of both forces (FA and M) occurs, the values mentioned above are invalid. Please contact VAT for more information. FA M

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

2.2.3 Compressed air connection

Connect air pressure to inputs '1' of the solenoids (internal thread R 1/8“, 1/8“ NPT for USA) Solenoid valve: Solenoid valve for impulse actuation: Make sure the emergency operation screws are in remote position (fully counter-clockwise) Note: Compressed air pressure (above atm): 4 - 7 bar / 56 -98 psi Attention: For proper function of the valve it is essential to use equal air pressure at OPEN -, CLOSE - and MIDDLE Pos. inlets. See table on page 6. Please consider that different solenoids, tube lengths and diameters can affect the air pressure. Compressed air may only be connected if - valve has been installed into the vacuum system - moving parts cannot be touched Use only clean, dry or slightly oiled air! For secure switching of solenoids, the inner diameter of the air connection tubes has to be: 4 mm for lengths up to 1 m 6 mm for lengths from 1 m to 5 m 8 - 10 mm for lengths above 5 m 2 4 3 1 5 2 4 3 1 5 schematic: schematic:

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

2.2.4 Actuator position (example)

Position A (Standard) Position B (Option) Note: For actuator position of your valve refer to the dimension diagram of your valve.

2.2.5 Compressed air connection by external solenoid (option)

Required solenoids: - Two 5/2 way valves Air connections : - Adapter with internal thread R 1/8“ (1/8“ NPT for USA) mounted to the pipe thread screws 'A' and 'B' instead of the solenoids. The pipe thread screws have also the function of an orifice for air pressure reduction. They must not be removed or replaced. - L-type connection 'C' with internal thread R 1/8“ and integrated orifice for air pressure reduction (DN 63 - 200: 1.4 mm, DN 250 - 400: 1.8mm) Apply compressed air pressure according the following table: Actuator on „A-position“ (Standard) A B C open position 1 0 0 intermediate position 1 0 1 closed position 0 1 1/0 Actuator on „B-position“ (Option) A B C open position 0 1 1/0 intermediate position 1 0 1 closed position 1 0 0 1 = air pressure 0 = no air pressure

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

2.2.6 Electrical connection

Verify that mains voltage matches voltage stated on the solenoid! Sockets for position indicator and solenoid are supplied with the valve. Do not touch electrical parts under voltage! Electrical power may only be connected if: valve has been installed into the vacuum system moving parts cannot be touched Wire solenoid and position indicator according to the following diagrams. Solenoid Position indicator for 3 positions 2power MV MV Lz Lg Lo 4 3 MV1 = solenoid for main cylinder (next to pneumatics) MV2 = solenoid for auxiliary cylinder Lo = position indicator «open» Lg = position indicator «closed» Lz = position indicator for intermediate position Control logic for actuator on valve seat side (A-side) MV1 MV2 Control logic for actuator on valve seat side (B-side) MV1 MV2 open position + + open position + + intermediate position + - intermediate position - + closed position - - closed position - - + = solenoid coil supplied with current + = solenoid coil supplied with current - = solenoid coil not supplied with current - = solenoid coil not supplied with current

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27 Solenoid for impulse actuation (option) 2power MV MV 2power MV MV V1 = impulse solenoid for main cylinder (next to pneumatics) V2 = impuse solenoid for auxiliary cylinder MV1 = solenoid coil for opening MV2 = solenoid coil for closing To open energize the solenoids MV1 of V1 and V2 simultaneously To close energize the solenoids MV2 of V1 and V2 simultaneously To throttle energize the solenoids MV1 of V1 and MV2 of V2 simultaneously Actuator on A side V1 V2 Actuator on B side ( solenoid turned 180 °) V1 V2 MV MV MV MV MV MV MV MV open position + - + - open position + - + - intermediate position + - - + intermediate position - + + - closed position - + - + closed position - + - + + = solenoid coil supplied with current - = solenoid coil not supplied with current + = solenoid coil supplied with current - = solenoid coil not supplied with current

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

3 Operation

3.1 Normal operation

Operation is allowed only after proper installing procedure.

3.1.1 Adjustment of the intermediate position

The intermediate position can be adjusted (allen wrench 8mm) independently of the air pressure by means of the bolt screw 'M' (see also page 7 and picture below), on the face side of the auxiliary cylinder. Before moving the bolt screw 'M', open the locking screw (B) (allen wrench 2.5mm). After adjustment the intermediate position, fasten the locking screw (B). For easy adjustment, VAT is recommending to switching off the compressed air during adjustment of the intermediate position. A-side actuator: turning bolt screw 'M' clockwise moves the intermediate position to open B-side actuator: turning bolt screw 'M' clockwise moves the intermediate position to close The position indicator on the valve can be adjusted for the set intermediate position. Move valve with bolt screw 'M' to the desired position and than turn the screw (A) with a screwdriver size 2 on top of the position indicator box in either direction until the microswitch Lz switches. (Lz = position indicator for intermediate position) A position indicator for intermediate position M B

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

3.2 Operation under increased temperature

See «1.1 Technical data»

3.3 Behavior in case of differential pressure

Note: Do not open the valve, if the differential pressure on the gate is larger than 30 mbar.

3.4 Behavior in case of compressed air failure

Valve closed: valve stays closed and leaktight Valve open or Intermediate position: valve stays open or moves into closed (not leaktight) position, depending on the mounting position

3.5 Behavior in case of power failure

Standard solenoids: valve closes Impulse solenoids: valve moves to the position of last command and stays in this position The solenoids can be actuated manually in case of power failure according to the following instructions: Standard solenoid valve Solenoid for impulse actuation (option) Emergency operation screw Emergency operation screw SV1 SV2 To open the valve: Turn emergency operation screw fully clockwise To close the valve: Turn emergency operation screw fully counter- clockwise Attention! Remote operation is only possible when the screw is turned fully counter-clockwise To open the valve: Turn emergency operation screws of coils «SV1» clockwise to mechanical stop. Turn back emergency operation screws counter-clockwise as soon the valve is open To close the valve: Turn emergency operation screws of coils «SV2» clockwise to mechanical stop. Turn back emergency operation screws counter-clockwise as soon the valve is closed Attention! Remote operation is only possible when both screws are turned fully counter-clockwise

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

4 Trouble shooting

Valve does not close/open/control Compressed air? Electrical connection? Differential pressure Mechanical parts blocked? Check compressed air at solenoids Is differential pressure < 30 mbar? Do not operate valve, while differential pressure is > 30 mbar. Equalize pressure first. Is valve cable connected properly? Mechanical parts blocked? (cleaning) Leak at gate Sealing surface gate Gate O-ring Clean valve seat and gate! Check surface of seat and O-ring Change O-ring, if necessary Leak at body Leak check Flange seals leaktight? Bonnet seal leaktight? Screws at bonnet tightened properly? If you need any further information, please contact one of our service centers. You can find the addresses on our website: http://www.vat.ch

5 Maintenance & repairs

Under clean operating conditions, the valve does not require any maintenance during the specified cycle life. Contamination from the process may influence the function and requires more frequent maintenance. Before carrying out any maintenance or repairs, please contact VAT. It has to be individually decided whether the maintenance/repair can be performed by the customer or has to be carried out by VAT. The fabrication number on the valve made in Switzerland Fabrication No.: patented . . Fabrication number has always to be specified. All supplies (e. g. compressed air, electrical power) must be disconnected for removal/installation of the valve from/into th e system and for maintenance work. Even with disconnected supply, loaded springs and/or air cushions in cylinders can be potential hazards. Keep fingers and objects away from the valve opening!

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27 Products returned to VAT must be free of harmful substances such as e.g. toxical, caustic or microbiological ones. If products are radioactively contaminated, fill in the VAT form «Contamination and Radiation Report» and send it with the product. The form is available at VAT. The maximum values indicated in the form must not be exceeded.

5.1 Preventive maintenance

The numbers in brackets refer to the drawing on page 17. Note! The process environment of your application (i.e. corrosive gases, deposition on parts inside valve body) may suggest shorter preventive maintenance intervals than suggested below. Baking of the valve is highly recommended for contaminating processes. VAT offers customized heater box for series 64 valves. For quick maintenance, VAT recommends to exchange the complete gate assembly in order to reduce the downtime of the system. Warning! DN 160 – 400: Never remove the striking plate (22) of the ball guidance (18)! Recommended maintenance after every 100'000 cycles (after 50'000 cycles for DN 400) Clean gate O-ring (or to replace it, if necessary), clean the inside surfaces Inspect the bonnet seal and inspect ball bearings and crank bolt Replace all parts witch are per process caused corrosion or material pollution (recommended spare parts kit 'C') Recommended maintenance after every 200'000 cycles (after 100'000 cycles for DN 400) Additional to the 100'000 cycles maintenance interval, VAT recommends to clean and lubricate the ball bearings (replace it, if necessary), replace the locking balls, replace the crank bolt, inspect, clean and re-lubricate the ball guide plate (replace it if the balls have seized in the bushings), inspect, clean and re-lubricate the feedthrough O-ring (replace it if necessary) The following table refers to the procedures in the following chapter and the spare parts list on page 17. Cycles *) Procedures Recommended spare parts kits Every 100’000 1., 2., 3. A, E For individual items see spare parts list on page 8 For individual items see spare parts list on page 8 *) Definition of a cycle: Movement of the gate from open into closed or control position and back into open position

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

5.1.1 Procedures

  1. Precondition for all maintenance work Vent both valve chambers Open gate valve Shut off air supply and electrical power Disconnect all cables to the actuator 2. Removal of the gate assembly (4) / Replacement of the crank bolt (6) / Replacement of the bonnet seal (3) Unfasten the bonnet screws (1) Remove the bonnet plate (2) and the bonnet seal (3) Pull the lever (17) a little bit out of the bonnet opening Loosen the hexagonal socket-head bolt (7) for the crank bolt (6) Remove the crank bolt (6), while lifting the gate assembly (4) a little bit if necessary Slide out the gate assembly (4) carefully from the body and put it on a clean workshop place Re-assemble in reverse direction Fasten the screws (1) crosswise with equal torque:

14 Nm (10 lbf ft) with DN 63 - 100

18 Nm (13 lbf ft) with DN 160 - 400

  1. Replacement of the gate O-ring (5) Put a suitable tool beneath the O-ring at the venting hole and lift the O-ring carefully out of the groove (take care that the groove will not be damaged) Clean groove and sealing surface Install new O-ring by pressing it crosswise uniformly into the groove. Make sure, the O-ring is not twisted (pay attention to the seam of the O-ring) 4. Replacement of the ball bearings (24) DN 63, DN 160 - 200: Replace the complete ball bearing assembly (DN 63: 1 pc, DN 160 - 200: 2 pcs) DN 100, DN 250 - 400: Replace each single ball bearing and pull out the its centre ring (4 pcs) 5. Replacement of the locking balls (21) Put the gate assembly (4) carefully on a clean workshop place with the O-ring side to the bottom DN 63: Push center spring down and dismount two-piece circlip from the center bearing. Lift off ball guide plate DN 100 - 400: Unscrew the hexagonal nuts (19). Lift off counter plate (20) and ball guide plate (18) Remove the locking balls (21)

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27 6. Replacement of actuator Close and lock valve Remove the position indicator box (8) from the actuator and unscrew the 2 hexagon bolts of the actuator Pull off actuator from the gear wheel of the feedthrough assembly (9). Take hold of the actuator on both sides of the actuator flange and use your thumb to push against the shaft of the feedthrough Make sure that rack of the actuator is in closed position Check whether valve is closed and properly locked Set up actuator on gear wheel and shaft in a right angle to the valve. If the actuator cannot engage with the gear wheel, turn actuator under little pressure a few degrees counter-clockwise until it engages with the gear wheel For change into position A2 or B2, first unscrew the 2 hexagonal bolts of the feedthrough assembly and put them into the bolt holes in the lateral axis Turn the actuator slightly back to the right angle position so that the 2 bolts can fit loosely in the threaded holes Fasten the 2 bolts only when flange area of the actuator lies tightly on the actuator flange of the valve Set position indicator box (8) on actuator Align position indicator so that the 4 cylinder head screws will fit loosely in the threaded holes. Fasten screws Verify the correct adjustment of the position indicator. In the position where the microswitch has switched, the valve must be closed and locked 7. Replacement of feedthrough O-ring (11) Remove gate assembly (4) as per items 1 and 2 Remove actuator as per item 6 Push the roll pin (12) out of the feedthrough shaft. Use VAT feedthrough assembling tool or a punch. Remove lever (17). Loosen the 2 screws of the feedthrough assembly (9) Slide out complete feedthrough assembly (9), carefully dismantle feed through assembly and remove the feedthrough O-ring (11)

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

6 Drawing

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

7 Spare parts

Please specify the fabrication number of the valve (see yellow label on valve) when ordering spare parts. This is to ensure that the appropriate spare parts are supplied. The item numbers refer to the assembly drawing on page 17 Item Description DN 63 DN 100 DN 160 DN 200 DN 250 DN 320 DN 350 DN 400

3 Bonnet seal 77775-R1 77778-R1 77781-R1 77784-R1 N-5100-378 N-5100-382 N-5100-383

4 Gate assembly 89146-R1 94842-R1 84275-R1 84608-R1 83481-R1 409173 215561

5 Gate O-ring N-5102-340 N-5102-351 N-5102-364 N-5100-372 N-5102-453 N-5102-457 N-5100-461

6 Crank bolt 79090-R1 79090-R1 79090-R1 79090-R1 85783-R1 85783-R1 87749-R1

7 Crank bolt mounting screw

9 Feedthrough assembly 96443-R1 96443-R1 95937-R1 95937-R1 96444-R1 96444-R1 96452-R1

12 Feedtrough connection pin N-6097-478 N-6097-478 N-6097-480 N-6097-480 N-6097-509 N-6097-509 N-6097-509 3-position pneumatic actuator, consisting of - pneumatic actuator (16) - 3-position pneumatics (15) - solenoid set (14) - position indicator (8) 83580-R1 230400 234418 60550-R1 83580-R1 230400 234418 60550-R1 83581-R1 226400 84476-R1 60550-R1 83581-R1 226400 84476-R1 60550-R1 83582-R1 230600 83586-R1 60550-R1 83582-R1 230600 83586-R1 60550-R1 83582-R1 230600 237670 60550-R1

10 Static actuator seal N-5100-222 N-5100-222 N-5100-225 N-5100-225 N-5100-228 N-5100-228 N-5100-228

11 Feedtrough O-ring

(option R1/8“ port: 2 pcs) N-5100-316 N-5100-316 N-5100-319 N-5100-319 N-5100-322 219930 N-5100-322

21 Locking balls N-6121-052

(8 pcs) N-6121-052 (12 pcs) N-6121-051 (18 pcs) N-6121-051 (24 pcs) N-6121-081 (18 pcs) N-6121-081 (24 pcs) N-6121-097 (32 pcs)

24 Ball bearing assembly 66856-R1

(1 pc) 67064-R1 (2 pcs) 84326-R1 (2 pcs) 80642-R1 (2 pcs) 99205-R1 (4 pcs) 99205-R1 (4 pcs) 77286-01 (4 pcs) A Seal kit vacuum 97442-R1 97446-R1 85047-R1 95939-R1 98472-R1 98474-R1 98476-R1 B Actuator replacement kit, consisting of: actuator seal, bonnet seal, feedthrough O-ring, feedthrough connection pin 101036-R1 (+static actuator seal) 101037-R1 (+static actuator seal) 88720-R1 88721-R1 88722-R1 88723-R1 88724-R1 C Gate spare parts kit, consisting of: gate O-ring, crank bolt, crank bolt mounting screw with spring washer, ball bearings, locking balls 101038-R1 (no ball bearings and locking balls) 101039-R1 (no ball bearings and locking balls) 88725-R1 88726-R1 88727-R1 88728-R1 88729-R1 D Feedtrough assembling tool 91001-R1 227400 E VAT vacuum grease (40g) N-6951-012

Installation, Operating & Maintenance Instructions Series 64, DN 63-400 (I.D. 21/2" - 16") VAT Vakuumventile AG, CH-9469 Haag, Switzerland Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 219034EM 2013-08-27

8 Warranty

Each product sold by VAT Vakuumventile AG (VAT) is warranted to be free from the manufacturing de fects that adversely affect the normal functioning thereof du ring the warranty period stated in VAT's «Terms of Sale» immediately following delivery thereof by VAT, provided that the same is properly ope rated under conditions of normal use and that regul ar, periodic maintenance and service is performed or replacements made, in accordance with the instructions provided by VAT. The foregoing warranty shall not apply to any product or component that has been repaired or altered by anyone other than an auth orized VAT representative or that has been subject to improper in stallation or abuse, misuse, negligence or accident. VAT shall not be liable for any damage, loss, or expen se, whether consequential, special, incidental, direct or otherwise, caused by, arising out of or connected with the manufacture, delivery (including any delay in or failure to deliver), packaging, storage or use of any pro duct sold or delivered by VAT shall fail to conform to the foregoing warranty or to the description thereof conta ined herein, the purchaser thereof, as its exclusive remedy, shall upon prompt notice to VAT of any such defect or failure and upon the return of the product, part or component in question to VAT at its factory, with transportation charges prepaid, and upo n VAT's in spection confirming the existence of any defect incon sistent with said warranty or any such failure, be entitled to have such defect or failure cured at VAT's factory and at no charge therefor, by replacement or repair of said product, as VAT may elect. VAT MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESS OR IMPLIED, (INCLUDING NO WAR RANTY OR MERCHANTABILITY), EXCEPT FOR THE FORE - GOING WARRANTY AND THE WARRANTY THAT EACH PRODUCT SHALL CONFORM TO THE DESCRIP TION THEREOF CONTAINED HEREIN, and no warranty shall be implied by law. Furthermore, the «Terms of sale» at the back of the price list are applicable.