Configure Your SCC System in Six Steps Step 1 – Select Your SCC Modules (Table 1) Analog input, analog output, and digital I/O modules have dedicated slots. You can select up to eight noncascaded modules for analog input and eight modules for digital I/O. You can install feedthrough modules in any slot, but they are especially useful for accessing counter/timers on your M Series, E Series, or B Series multifunction DAQ device. Step 2 – Choose an SCC Carrier (Table 2) SCC carriers are available either with a hinged lid or with configurable connectors using panelettes. Hinged lids provide quick access to the modules. Configurable connectors provide custom signal- interface options. Step 3 – Select Your Panelettes (Table 3) If you have chosen an SCC carrier with configurable connectors, you can also select connector and interface panelettes. Different carriers offer different numbers of panelette slots. Also, some panelettes occupy more than one slot. Step 4 – Determine Your Power Option (Table 4) You can power an SCC system using a +5 VDC, 120/240 VAC, or 7 to 42 VDC external power source. To indicate the power option for your SCC system, select 01, 02, or 03 as the last two digits of the part number of the SC-2345 or SC-2350 carrier. Please note that if you choose power option 01, it is possible to power your SCC system using the internal power source of your DAQ device. For DAQCard and DAQPad devices, the total power required by your SCC modules must be less than 800 mW (490 mW of analog power). For PCI or PXI and M Series or E Series multifunction DAQ devices, the total power required by your SCC modules must be less than 4.55 W (1.74 W for analog modules). Additional power modules are sold separately. To determine the power requirements of the modules in your SCC DAQ system, use the online SCC Advisor at ni.com/advisors. Step 5 – Select Your DAQ Device and Cable (Table 5) Select the DAQ device to control your system. Step 6 – Select Your Accessories Choose from rack/panel-mount kits and stacking kits. You can also select additional power kits separately if your application requires multiple power configurations.
- Ideal for portable measurement systems
- Wide variety of direct signal and sensor connectivity options
- Wide range of analog and digital conditioning options
- Measurement type selectable on a per-channel basis
- Front-end signal conditioning for M Series, E Series, and some B Series multifunction DAQ devices SCC – Portable, Low-Cost Signal Conditioning
250 VAC
1The switching capability of SCC-RLY01 is not 5 A at 250 VAC throughout – it is 5 A at 250 VAC only if it is used with SCC-68, a nd it is 5 A at 30 VAC if used with SC-2345. Table 1. SCC Module Selection Guide
visit the SCC Advisor at ni.com/advisors.
120 VAC, 240 VAC External1 -02
1AC transformer included. However, you must purchase a separate power cord to match your country’s power requirements. 2External power supply not included. Table 4. SC-2345/SC-2350 Power Options Table 5. National Instruments DAQ Devices Table 3. Panelettes Table 2. SCC Carriers
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) NI SCC-TC Series Thermocouple Input The National Instruments SCC-TC01 and SCC-TC02 are single-input modules for conditioning signals from a variety of thermocouple types, including J, K, T, B, E, N, R, and S, and millivolt inputs with a range of ±100 mV. The NI SCC-TC modules include a 2 Hz lowpass filter, an instrumentation amplifier with a gain of 100, and buffered outputs for maximum scanning rates by the multifunction DAQ device. The input circuitry of the SCC-TC modules also includes high-impedance bias resistors for open-thermocouple detection as well as handling both floating and ground-referenced thermocouples. The SCC-TC modules include an onboard thermistor for cold-junction compensation. Two versions of the SCC-TC are available. The SCC-TC01 includes a 2-prong uncompensated thermocouple jack that accepts any miniature or subminiature 2-prong male thermocouple plug. The SCC-TC02 includes a removable screw-terminal plug that features an additional connection for grounding thermocouple shields. Specifications SCC-TC Series Typical for 25 °C unless otherwise noted. Input Characteristics E, N, R, and S, ±100 mV Overvoltage protection pk (powered on or off) Input impedance Open thermocouple detection current 250 nA maximum rms, referred to input Stability Cold-junction sensor (thermistor) (at 55 °C) Power Requirements Portable, Modular Signal Conditioning Modules Model Channel Description Part Number SCC-TC01 1 Thermocouple, spade connector 777459-03 SCC-TC02 1 Thermocouple, screw terminals 777459-04
The National Instruments SCC-RTD01 is a dual-channel module that accepts 2, 3, or 4-wire platinum RTDs. Each channel of the NI SCC-RTD01 has an amplifier with a gain of 25 and a 30 Hz lowpass filter. In addition, the module has a 1 mA excitation source for powering the RTDs. Specifications SCC-RTD01 Analog Input on each channel) Maximum working voltage ±12 V of ground or off) powered on; 20 kΩmin powered off rms (referred to input) Transfer Characteristics Offset-error temperature coefficient .. ±1.6 µV/°C Amplifier Characteristics Excitation Maximum voltage level without Environment Power Requirements Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-RTD01 2 2, 3, or 4-wire Pt RTD 777459-18
Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) NI SCC-SG Series Strain Gage Input/Excitation The National Instruments SCC-SG Series consists of dual-channel strain gage modules for conditioning quarter, half, and full-bridge strain gages and a calibration module. Each module is designed for a specific type of bridge configuration. Each channel of an NI SCC-SG module (except SCC-SG11) includes an instrumentation amplifier, a 1.6 kHz lowpass filter, and a potentiometer for bridge-offset nulling. Each SCC-SG0x module also includes a single 2.5 V excitation source. The SCC-SG24 has a 10 V excitation source for load cells and pressure sensors. The SCC-SG11 is a dual-channel shunt calibration module for use with the SCC-SG0x and SCC-SG24 modules. Each channel includes two terminals for wiring a switched 301 kΩ, 1 percent, 1⁄4 W resistor across any two points of your bridge. You enable shunt calibration for both channels of a module by writing a logic high to the digital line controlling the SCC-SG11. You disable shunt calibration by writing a logic low to the same digital line. When you install an SCC-SG module in the SC-2345, the carrier routes the strain gage signals to two input channels of the multifunction DAQ device, channels x and x+8, where x is 0 through 7. Specifications SCC-SG0x Input Characteristics p (powered on or off) powered off or overload Excitation Current Drive Power Requirements SCC-SG11 Power Requirements SCC-SG24 Input Characteristics powered off powered off or overload calibration filter 350 Ωstrain gages Power Requirements 1By factory default, the nulling resistors are not installed in the SCC-SG24. See the user manual for information on installing the nulling resistors. Model Channel Description Part Number SCC-SG01 2 120 Ω, quarter-bridge strain gages 777459-13 SCC-SG02 2 350 Ω, quarter-bridge strain gages 777459-14 SCC-SG03 2 Half-bridge strain gages 777459-15 SCC-SG04 2 Full-bridge strain gages 777459-16 SCC-SG11 2 Shunt calibration 777459-17 SCC-SG24 2 Full-bridge strain gages, load cells, pressure sensors, torque sensors 777459-37
NI SCC-CTR01 Counter/Timer Isolation The National Instruments SCC-CTR01 is an isolated general-purpose counter/timer module for the SCC platform. This module performs in a wide variety of counter/timer tasks, including quadrature encoder measurement, edge counting, frequency measurement, pulse-width- modulation (PWM) generation, and pulse-train generation. With optical isolation, the test system and UUT are protected from transient voltage spikes when the signals are connected to the SCC-CTR01. The SCC-CTR01 also features short-circuit protection that disables the outputs if current limits are reached. Specifications SCC-CTR01 Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-CTR01 1 0 to 48 V isolated counter/timer 779474-01
Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) NI SCC-ACC01 Accelerometer Input The National Instruments SCC-ACC01 is a single-channel module that accepts Integrated Electronic Piezoelectric (IEPE) compatible sensors such as accelerometers and microphones. The NI SCC-ACC01 has an amplifier with a gain of two, a 0.8 Hz highpass filter, and a 19 kHz 3-pole Bessel lowpass filter. The maximum input range is ±5 V. In addition, this module has a 4 mA current source to power an accelerometer or microphone. When you install the SCC-ACC01 into the SC-2345, the carrier routes the single output voltage to one input channel of the multifunction DAQ device, channel x, where x is 0 through 7. For example, if installed into the J1 socket of the SC-2345, the output voltage is routed to input channel 0 of the DAQ device. Specifications SCC-ACC01 Analog Input ±1 dB, 5 Hz to 10 kHz Maximum working voltage ±12 V of ground or off) (powered on or off) rms (referred to input) Transfer Characteristics Offset-error temperature coefficient .. ±1.6 µV/°C Amplifier Characteristics Excitation Maximum voltage level Environment Power Requirements Model Channel Description Part Number SCC-ACC01 1 Accelerometer input 777459-19
NI SCC-AI Series Isolated Analog Input National Instruments SCC-AI Series modules are dual-channel bank- isolated analog input modules for reading input voltages from ±50 mV to ±42 V. Each channel of an NI SCC-AI module includes an instrumentation amplifier, a lowpass filter, and a potentiometer for calibration. These modules are installation rated for CAT I, and provide safety working isolation of 60 VDC per module. Specifications SCC-AI Series Input Characteristics per module
100 MΩ(all others)
1Test isolation voltage is 2,350 VAC for 2 s. Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Input Range Bandwidth Part Number SCC-AI01 2 ±42 V 10 kHz 777459-20 SCC-AI02 2 ±20 V 10 kHz 777459-21 SCC-AI03 2 ±10 V 10 kHz 777459-22 SCC-AI04 2 ±5 V 10 kHz 777459-23 SCC-AI05 2 ±1 V 10 kHz 777459-24 SCC-AI06 2 ±100 mV 10 kHz 777459-25 SCC-AI07 2 ±50 mV 10 kHz 777459-26 SCC-AI13 2 ±10 V 4 Hz 777459-27 SCC-AI14 2 ±5 V 4 Hz 777459-28 Module Input Range Output Range Gain Filter Bandwidth SCC-AI01 ±42 V ±8.4 V 0.2 10 kHz SCC-AI02 ±20 V ±10 V 0.5 10 kHz SCC-AI03 ±10 V ±10 V 1 10 kHz SCC-AI04 ±5 V ±10 V 2 10 kHz SCC-AI05 ±1 V ±10 V 10 10 kHz SCC-AI06 ±100 mV ±10 V 100 10 kHz SCC-AI07 ±50 mV ±10 V 200 10 kHz SCC-AI13 ±10 V ±10 V 1 4 Hz SCC-AI14 ±5 V ±10 V 2 4 Hz
Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) NI SCC-AO10 Isolated Analog Output The National Instruments SCC-AO10 is a single-channel isolated analog voltage output module with an output range of ±10 V. Each channel of the NI SCC-AO10 is referenced to its own isolated ground, allowing up to
60 VDC of common-mode voltage between grounds (channel-to-channel
or channel-to-chassis). In addition, the SCC-AO10 increases the output current drive capacity of an M Series, E Series, or B Series multifunction DAQ device to ±30 mA. Because the modules are isolated, you can cascade two SCC-AO10 modules for an output range of ±20 V. There is a maximum of two SCC-AO10 modules per carrier. Note: Use the SCC-AO10 with only multifunction DAQ devices that have analog outputs. Specifications SCC-AO10 Output Characteristics rms typ; 4 mVrms max Safety Isolation Channel-to-earth Environment Stability Output offset temperature Power Requirements Model Channel Description Part Number SCC-AO10 1 ±10 V isolated voltage output 777459-50
NI SCC-A10 Voltage Attenuator The National Instruments SCC-A10 is a dual-channel module that accepts input voltage sources up to 60 VDC. Each channel of the NI SCC-A10 includes a 10:1 attenuation circuit and differential instrumentation amplifier with low-impedance outputs for maximum scanning rates by the multifunction DAQ device. The attenuation circuit includes high-impedance bias resistors, so you can connect floating or ground-referenced inputs to the SCC-A10 without adding external bias resistors. The SCC-A10 also provides overvoltage protection (up to 250 V rms) for your DAQ system. When you install an SCC-A10 module in the SC-2345, the carrier routes the attenuated input signals to two input channels of the DAQ device, channels x and x+8, where x is 0 through 7. Specifications SCC-A10 Input Characteristics to input) Input impedance Power Requirements Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-A10 2 Attenuator input 777459-06
Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) NI SCC-LP Series Lowpass Filters The National Instruments SCC-LP Series consists of dual-channel lowpass filter modules that accept two ±10 V signals. Each channel has a 4th-order Butterworth filter. The cutoff frequency is specific to the module and applies to both channels of the module. Specifications SCC-LP Series Amplifier Characteristics powered on 10 kΩpowered off or overload Filter Characteristics SCC-LP02 = 50 Hz SCC-LP03 = 150 Hz SCC-LP04 = 1 kHz Passband Ripple Fc = cutoff frequency System Noise Wide band noise Narrow band noise (DC to 33 kHz, referred to input) .... 6 µV rms Stability maximum maximum Power Requirements SCC-LP01, LP02 SCC-LP03, LP04 Model Channel Description Part Number SCC-LP01 2 Lowpass filter (25 Hz) 777459-07 SCC-LP02 2 Lowpass filter (50 Hz) 777459-08 SCC-LP03 2 Lowpass filter (150 Hz) 777459-09 SCC-LP04 2 Lowpass filter (1 kHz) 777459-10 Passband Typical Maximum DC to 1⁄3Fc 0 ± 0.04 dB max 0 ± 0.1 dB max DC to 1⁄2Fc 0 ± 0.06 dB max 0 ± 0.2 dB max DC to 2⁄3Fc -0.2 ± 0.25 dB max -0.2 ± 0.4 dB max DC to Fc -3 ± 0.3 dB max -3 ± 0.5 dB max
NI SCC-FV01 Frequency Input Module The National Instruments SCC-FV01 is a dual-channel frequency-to- voltage conversion module that accepts ±10 V signals up to 100 Hz. The output scales linearly with the input frequency, and goes to 0 V with a DC input signal. Each channel triggers on the incoming signal using a threshold of 0 V and a hysteresis of 200 mV. For isolated solutions, consider using the SCC-AI03 cascaded with the NI SCC-FV01. Specifications SCC-FV01 Input Characteristics Minimum input pulse width or off) Input impedance Transfer Characteristics Output offset temperature pp at 10 Hz Power Requirements 1Recommended; minimum 100 mV. NI SCC-CI20 Current Input The National Instruments SCC-CI20 is a dual-channel module that accepts two 0 to 20 mA or 4 to 20 mA current loop inputs. Each independent channel of the NI SCC-CI20 includes a precision 249 Ω current conversion resistor that converts a 0 to 20 mA signal into a 0 to 5 V signal. Each channel includes a differential instrumentation amplifier with low-impedance outputs for maximum scanning rates by the multifunction DAQ device, and bias resistors for handling both floating and ground-referenced current sources. The SCC-CI20 also includes two spare 249 Ωresistors. When you install the SCC-CI20 in the SC-2345, the carrier routes the two output voltages to two input channels of the DAQ device, channels x and x+8, where x is 0 through 7. For example, if you install the module in the J1 socket of the SC-2345, the output voltages are routed to input channels 0 and 8 of the DAQ device. Specifications SCC-CI20 Input Characteristics Power Requirements Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-FV01 2 Frequency-to-voltage conversion (0 to 100 Hz) 777459-32 Model Channel Description Part Number SCC-CI20 2 0 to 20 mA current input 777459-05
NI SCC-CO20 Isolated Current Output The National Instruments SCC-CO20 is a single-channel isolated current output module that can provide up to 20 mA. This module is installation rated for CAT I, and provides a safe working voltage of 60 VDC. Because the modules are isolated, you can connect two NI SCC-CO20 modules in parallel to provide up to 40 mA. The SCC-CO20 plugs into either analog output socket, J17 or J18. The voltage applied to the module from an analog output channel of a multifunction DAQ device sets the current output. Because there are two output channels on DAQ devices, there are a maximum of two SCC-CO20 modules per carrier. Note: Use the SCC-CO20 with only multifunction DAQ devices that have analog outputs. Specifications SCC-CO20 Output Characteristics Safety Isolation Environment Power Requirements NI SCC-DI01 Optically Isolated Digital Input The National Instruments SCC-DI01 is a single-channel, optically isolated digital input module for sensing digital signals up to 30 VDC, including TTL. This digital input module can sense both AC and DC signals and has a status LED for visual verification of the module input status. The NI SCC-DI01 fits in any SC-2345 socket J9 through J16. When you install an SCC-DI01 in one of these sockets, the digital signal is automatically routed to a DIO line of the multifunction DAQ device. For example, socket J9 connects to digital line 0 of the data acquisition device. Because you can configure multifunction DAQ devices for input or output on a line-by-line basis, you can have between one and eight SCC-DI01 modules per carrier. Specifications SCC-DI01 Input Characteristics Digital Logic Levels Input current Power Requirements Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-C020 1 Isolated current output 777459-33 Model Channel Description Part Number SCC-DI01 1 Isolated digital input 777459-11
SCC-DO01 Optically Isolated Digital Output The National Instruments SCC-DO01 is a single-channel, optically isolated digital output module for switching external devices. The NI SCC-DO01 optical isolation circuitry handles up to 24 VDC and includes a status LED for visual verification of the module output status. The SCC-DO01 includes an external switch with which you can configure the power-up state of the module either high or low. The SCC-DO01 plugs into any SC-2345 socket between J9 and J16. When you install the module in one of these sockets, the digital signal is controlled by a DIO line of the multifunction DAQ device. For example, socket J9 connects to digital line 0 of the DAQ device. Because you can configure DAQ devices for input or output on a line-by-line basis, you can have from one to eight SCC-DO01 modules per carrier. Specifications SCC-DO01 Output Characteristics Digital Logic Levels Configuration 1 Configuration 2 Maximum continuous load current (I Minimum load resistance (at V ss = 24 V) Power Requirements NI SCC-RLY01 SPDT Relay The National Instruments SCC-RLY01 is a single-channel relay module for switching external devices. It contains one single-pole, double-throw (SPDT) relay capable of switching 5 A at 30 VDC or 250 VAC when used with the SCC-68 and 5 A at 30 VDC or 30 VAC when used with the SC-2345. The NI SCC-RLY01 uses positive logic. A digital high sets the relay, and a digital low resets it. The SCC-RLY01 plugs into any SC-2345 socket between J9 and J16. When inserting an SCC-RLY01, a DIO line of the multifunction DAQ device controls the digital signal. For example, socket J9 connects to digital line 0 of the data acquisition device. Because you can configure the DAQ devices for input or output on a line-by-line basis, you can have from one to eight SCC-RLY01 modules per carrier. Specifications SCC-RLY01 Switching time 7 operations at 180 operations/minute (minimum) 1The nominal switching voltage is 250 VAC when using a high-voltage backshell in an NI SCC-68 carrier. Otherwise the module is rated for only 30 VAC. Logic Level Output Voltage Level between Vout and Vcom Low (I02 = 25 mA) 0.4 V High (I02 = 0 mA) Vss Logic Level Output Voltage Level between Vout and Vcom Low (I01 = 0 mA) 0 V High (I01 = 25 mA) 22 VDC at Vss = 24 V
3 VDC at Vss = 5 V
Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-DO01 1 Isolated digital output 777459-12 Model Channel Description Part Number SCC-RLY01 1 SPDT relay 777459-34
The National Instruments SCC-FT01 is a feedthrough module that offers direct connection to analog input, analog output, digital I/O, and GPCTR channels of the DAQ device. For analog input channels, you can connect to either two single-ended or one differential channel. The NI SCC-FT01 includes a breadboard area for development of custom signal conditioning circuitry. If you install the SCC-FT01 in an analog input socket (J1 through J8, SC-2345 or SC-2350) or analog output socket (J17 or J18, SC-2345 only) then you have direct connection to the corresponding channels of the DAQ device. You can add custom conditioning to the SCC-FT01 for these analog inputs or outputs. In any socket, the SCC-FT01 module has access to 5 and ±15 VDC power. If you use the breadboard area for custom conditioning, you can cascade the SCC-FT01 with other SCC modules for dual-stage conditioning. Specifications SCC-PWR Series SCC-PWR01 source, or +5 VDC from DAQ device ±15 VDC, 62% efficiency SCC-PWR02 SCC-PWR03 ±15 VDC, 46% efficiency Physical Dimensions (3.5 by 1.2 by 0.7 in.) (9.5 by 10.3 by 1.6 in.) SC-2345 with configurable (12.1 by 10 by 1.7 in.) External AC adapter (6.1 by 3.3 by 1.9 in.) Connectors minithermocouple connector connector Certification and Compliance European Compliance Table 1 Immunity North American Compliance Australia and New Zealand Compliance For more information about certifications, visit ni.com/certification. Portable, Modular Signal Conditioning Modules BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Model Channel Description Part Number SCC-FT01 2 SE/1 DI Feedthrough 777459-01
© 2007 National Instruments Corporation. All rights reserved. DAQCard, DAQPad, National Instruments, National Instruments Allia nce Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-ventu re relationship with NI. National Instruments • info@ni.com ni.com • 800 813 3693 *351484A-01* 351484A-01 2007-9240-321-101-D NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services.