DESCRIPTION
The FC-4224 Fire Alarm Control panel is a proven, versa- tile, four-zone control with space to accommodate an op- tional digital communicator. It meets the requirements of NFPA Standard 72 for Central Station, Protected Premises, and Remote (DACT) Supervising Station Fire Alarm Sys- tems. It is Listed to UL Standard 864, inherently power lim- ited and meets all UL transient immunity requirements. The many features of the FC-4224 control provide a cost-effective approach to systems design, and allow a great degree of flexibility in one enclosure. These features include a choice of four (4) Class B, Style B or two (2) Class A, Style D initiating circuits together with a choice of two (2) Class B, Style Y or one (1) Class A, Style Z notification appliance cir- cuit, rated at 1.25 amps each. Notification appliance circuits can be configured as silenceable or non-silenceable. DIP switch programming is used throughout, eliminating the need for computers and associated software. A time delay of 30, 60 or 90 seconds is available for waterflow switches. The control is housed in a red steel enclosure with a win- dow offering a view of LEDs displaying the status of vital functions and allowing access to switches controlling system operation. The surface mounted enclosure, with its slim ap- pearance (3 3/8-inch depth) is designed to blend with any en- vironment. Space is available for two (2) B-7R batteries. Supervision of vital components, plug-in modules, func- tional switches and standby batteries is provided. The optional digital communicator includes a wide range of selectable transmission formats to communicate to most central stations. Other features of the communicator are: A line-active indicator for each of two phone lines, “Kiss-Off” signal LED, dual “low telephone voltage detect” circuitry and programmable event codes per format. The FC-4224 control is programmable for AC power loss delay required for DACT operation. An optional serial annunciator driver allows remote alarm annunciation to as many as four (4) Model FC-2866 remote annunciators. Other optional modules include the FC-2880 I/O module which provides 34 pre-defined open collector outputs that can be used to drive LEDs or relays. AGENCY APPROV ALS UL S1869 CSFM Approved FC-4224 FOUR-ZONE PANEL CONVENTIONAL FIRE ALARM CONTROL
16 Southwest Park, Westwood, MA 02090 USA TEL: (781) 471-3000 FAX: (781) 471-3099
Specifications are provided for information only, are not intended to be used for installation purposes, and are believed to be accurate. However, no responsibility is assumed by Fire Control In- struments, Inc. for their use. Specifications subject to change without notice. © 2000 All Rights Reserved 9020-0484/Ver. 1.5
FEATURES
/c183Inherently Power Limited /c183DIP Switch Programming /c183Choice of Output Patterns Including ANSI S3.41 /c183Programmable Time Delay for Waterflow Switches /c183Periodic Trouble Reminder /c183Walk Test Feature /c183Optional Digital Communicator with Multiple Reporting Formats /c183Serial Annunciator Output (Optional) /c183Surface Mount Technology An ISO 9001 Certified Company
OPERATING CHARACTERISTICS AND DIMENSIONS Supervisory current .065 amp. Alarm current .250 amp Operating temperature 32 - 120o F (0 - 49o C) Relative humidity 85% (non-condensing) Dimensions 15 1/8” H x 12 13/16” W x 3 3/8” D (38.4 cm x 33 cm x 8.5 cm)
ORDERING INFORMATION
Part Number Model Description 150-00002 FC-4224 Four-zone Control, 120 V AC 151-00001 FC-2884 Serial Driver Module 151-00003 FC-2880 /c197 Annunciator Driver Module 151-00004 FC-2866 /c197 Remote Zone Annunciator w/reset and silence switches 151-00005 FC-2104 Digital Alarm Communicator Transmitter 151-00019 2190 Cabinet for FC-2104 DACT (optional) 151-00017 5230 Programmer for FC-2104 DACT 151-00018 7860 Cable w/spade lugs for connection to Telco RJ31X plug. (Optional) 151-00020 Quick connect cable to connect
5230 Programmer to FC-2104 DACT
151-00008 FC-4224PC Replacement printed circuit board
7628 UL Listed EOL resistor
151-00011 120 V AC Transformer (replacement) 151-00012 230 V AC, 50 Hz Transformer (optional) /c197Requires one (1) FC-2884 FC-2104 DACT reporting formats are: SIA 8 or 20 3/1 1,400 or 2,300 Hz Contact ID SK- 4/2 BFSK 1,400 or 2,300 Hz 9020-0484 2 of 2 FC-2880 Annunciator Driver Module FC-2884 Serial Driver Module FC-2866 Remote Zone Annunciator FC-2104 Digital Alarm Communicator Transmitter