RTE0T0002LKCE00000R RENESAS | Alldatasheet
Document overview
- Manufacturer or author: Renesas Electronics Corporation
- PDF pages: 36
Technical content
Datasheet sections
- 1.1 Package Components
- 1.2 System Configuration
- 1.3 PC Interface
- 1.4 Specifications
- 1.5 Regulatory Compliance Notices
- 1.5.1 European Union regulatory notices
- 1.5.2 United States regulatory notices
- 1.6 E2 Lite Hardware Configuration
- 1.7 Names of the Emulator Parts
- 1.8 Operating Environment
- 2.1 Installing Emulator Software
- 2.2 Connecting the E2 Lite to the Host Machine
- 2.3 Connecting the E2 Lite to the User System
- 2.4 Turning the Power On/Off
- 2.4.1 When a Separate Power Supply is Used for the User System
- 2.4.2 When Power is Supplied to the User System from the Emulator
- 2.5 Connecting System Ground
- 2.6 Hot plug-in
- 3.1 How to Solve a Trouble
- 3.1.1 The ACTIVE LED does not flash or light up
- 3.1.2 Unconnectable with the debugger
- 3.2 How to Request Support
- 4.1 Maintenance
- 4.2 Warranty
E2 emulator Lite RTE0T0002LKCE00000R User’s Manual All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corporation without notice. Please review the latest information published by Renesas Electronics Corporation through various means, including the Renesas Electronics Corporation website (http://www.renesas.com). Rev.3.00 May 2020 www.renesas.com
- Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples. You are fully responsible for the incorporation or any other use of the circuits, software, and information in the design of your product or system. Renesas Electronics disclaims any and all liability for any losses and damages incurred by you or third parties arising from the use of these circuits, software, or information. 2. Renesas Electronics hereby expressly disclaims any warranties against and liability for infringement or any other claims involving patents, copyrights, or other intellectual property rights of third parties, by or arising from the use of Renesas Electronics products or technical information described in this document, including but not limited to, the product data, drawings, charts, programs, algorithms, and application examples. 3. No license, express, implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights of Renesas Electronics or others. 4. You shall not alter, modify, copy, or reverse engineer any Renesas Electronics product, whether in whole or in part. Renesas Electronics disclaims any and all liability for any losses or damages incurred by you or third parties arising from such alteration, modification, copying or reverse engineering. 5. Renesas Electronics products are classified according to the following two quality grades: “Standard” and “High Quality”. The intended applications for each Renesas Electronics product depends on the product’s quality grade, as indicated below. "Standard": Computers; office equipment; communications equipment; test and measurement equipment; audio and visual equipment; home electronic appliances; machine tools; personal electronic equipment; industrial robots; etc. "High Quality": Transportation equipment (automobiles, trains, ships, etc.); traffic control (traffic lights); large-scale communication equipment; key financial terminal systems; safety control equipment; etc. Unless expressly designated as a high reliability product or a product for harsh environments in a Renesas Electronics data sheet or other Renesas Electronics document, Renesas Electronics products are not intended or authorized for use in products or systems that may pose a direct threat to human life or bodily injury (artificial life support devices or systems; surgical implantations; etc.), or may cause serious property damage (space system; undersea repeaters; nuclear power control systems; aircraft control systems; key plant systems; military equipment; etc.). Renesas Electronics disclaims any and all liability for any damages or losses incurred by you or any third parties arising from the use of any Renesas Electronics product that is inconsistent with any Renesas Electronics data sheet, user’s manual or other Renesas Electronics document. 6. When using Renesas Electronics products, refer to the latest product information (data sheets, user’s manuals, application notes, “General Notes for Handling and Using Semiconductor Devices” in the reliability handbook, etc.), and ensure that usage conditions are within the ranges specified by Renesas Electronics with respect to maximum ratings, operating power supply voltage range, heat dissipation characteristics, installation, etc. Renesas Electronics disclaims any and all liability for any malfunctions, failure or accident arising out of the use of Renesas Electronics products outside of such specified ranges. 7. Although Renesas Electronics endeavors to improve the quality and reliability of Renesas Electronics products, semiconductor products have specific characteristics, such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Unless designated as a high reliability product or a product for harsh environments in a Renesas Electronics data sheet or other Renesas Electronics document, Renesas Electronics products are not subject to radiation resistance design. You are responsible for implementing safety measures to guard against the possibility of bodily injury, injury or damage caused by fire, and/or danger to the public in the event of a failure or malfunction of Renesas Electronics products, such as safety design for hardware and software, including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other appropriate measures. Because the evaluation of microcomputer software alone is very difficult and impractical, you are responsible for evaluating the safety of the final products or systems manufactured by you. 8. Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product. You are responsible for carefully and sufficiently investigating applicable laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS Directive, and using Renesas Electronics products in compliance with all these applicable laws and regulations. Renesas Electronics disclaims any and all liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations. 9. Renesas Electronics products and technologies shall not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited under any applicable domestic or foreign laws or regulations. You shall comply with any applicable export control laws and regulations promulgated and administered by the governments of any countries asserting jurisdiction over the parties or transactions. 10. It is the responsibility of the buyer or distributor of Renesas Electronics products, or any other party who distributes, disposes of, or otherwise sells or transfers the product to a third party, to notify such third party in advance of the contents and conditions set forth in this document. 11. This document shall not be reprinted, reproduced or duplicated in any form, in whole or in part, without prior written consent of Renesas Electronics. 12. Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products. (Note1) “Renesas Electronics” as used in this document means Renesas Electronics Corporation and also includes its directly or indirectly controlled subsidiaries. (Note2) “Renesas Electronics product(s)” means any product developed or manufactured by or for Renesas Electronics. (Rev.4.0-1 November 2017) Corporate Headquarters Contact information TOYOSU FORESIA, 3-2-24 Toyosu, Koto-ku, Tokyo 135-0061, Japan www.renesas.com For further information on a product, technology, the most up-to-date version of a document, or your nearest sales office, please visit: www.renesas.com/contact/. Trademarks Renesas and the Renesas logo are trademarks of Renesas Electronics Corporation. All trademarks and registered trademarks are the property of their respective owners.
R20UT3240EJ0300 Rev.3.00 Page 3 of 36 May.15.20 Preface The E2 emulator Lite (RTE0T00020LKCE00000R; hereafter referred to as the E2 Lite) is designed for use with the devices made by Renesas Electronics. All components of the E2 Lite are listed under “1.1 Package Components”. If you have any questions about the E2 Lite, contact your local distributor. Documentation for the E2 Lite manual is in two parts. In using the E2 Lite, please be sure to read each of them. - The E2 emulator Lite user’s manual (this manual) - The additional documents for user’s manual for E1/E20 emulator or E2 emulator Lite This user’s manual describes mainly the hardware specifications of the E2 Lite. For information on emulator debuggers and other related products, please see the additional document for user’s manuals included with each product. You can download the latest manuals from the Renesas Tools homepage. https://www.renesas.com/e2lite
R20UT3240EJ0300 Rev.3.00 Page 4 of 36 May.15.20 Important Before using the emulator, be sure to read this user’s manual carefully. Keep this user’s manual, and refer to it when you have questions about the emulator. Emulator: "Emulator" in this user’s manual collectively refers to the E2 Lite manufactured by Renesas Electronics Corporation. "Emulator" herein encompasses neither the customer's user system nor the host machine. Purpose of use of the emulator: This emulator is a device to support the development of systems that uses the Renesas microcomputers. It provides support for system development in both software and hardware. By using in combination with a programming software, it is available as a flash programming tool. Be sure to use the emulator correctly according to said purpose of use. Please avoid using the emulator other than for its intended purpose of use. For those who use the emulator: The emulator can only be used by those who have carefully read the user’s manual and know how to use it. Use of the emulator requires basic knowledge of electric circuits, logical circuits, and MCUs. When using the emulator: (1) The emulator is a development-support unit for use in your program development and evaluation stages. When a program you have finished developing is to be incorporated in a mass-produced product, the judgment as to whether it can be put to practical use is entirely your own responsibility, and should be based on evaluation of the device on which it is installed and other experiments. (2) In no event shall Renesas Electronics Corporation be liable for any consequence arising from the use of the emulator. (3) Renesas Electronics Corporation strives to provide workarounds for and correct trouble with products malfunctions, with some free and some incurring charges. However, this does not necessarily mean that Renesas Electronics Corporation guarantees the provision of a workaround or correction under any circumstances. (4) The emulator covered by this document has been developed on the assumption that it will be used for program development and evaluation in laboratories. Therefore, it does not fall within the scope of applicability of the Electrical Appliance and Material Safety Law and protection against electromagnetic interference when used in Japan. (5) Renesas Electronics Corporation cannot predict all possible situations and possible cases of misuse that carry a potential for danger. Therefore, the warnings in this user's manual and the warning labels attached to the emulator do not necessarily cover all such possible situations and cases. The customer is responsible for correctly and safely using the emulator.
R20UT3240EJ0300 Rev.3.00 Page 5 of 36 May.15.20 (6) This emulator has acquired the standards shown in "1.5 Regulatory Compliance Notices". This fact must be taken into account when the emulator is taken from Japan to some other country. (7) Renesas Electronics Corporation will not assume responsibility of direct or indirect damage caused by an accidental failure or malfunction in the emulator. When disposing the emulator: Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation. Usage restrictions: The emulator has been developed as a means of supporting system development by users. Therefore, do not use it as an embedded device in other equipment. Also, do not use it to develop systems or equipment for use in the following fields. (1) Transportation and vehicular (2) Medical (equipment that has an involvement in human life) (3) Aerospace (4) Nuclear power control (5) Undersea repeaters If you are considering the use of the emulator for one of the above purposes, please be sure to consult your local distributor. About product changes: We are constantly making efforts to improve the design and performance of our product. Therefore, the specification or design of the emulator, or this user's manual, may be changed without prior notice. About rights: (1) We assume no responsibility for any damage or infringement on patent rights or any other rights arising from the use of any information, products or circuits presented in this user’s manual. (2) The information or data in this user’s manual does not implicitly or otherwise grant a license to patent rights or any other rights belonging to Renesas or to a third party. (3) This user’s manual and the emulator are copyrighted, with all rights reserved by Renesas. This user’s manual may not be copied, duplicated or reproduced, in whole or part, without prior written consent from Renesas. About diagrams: Some diagrams in this user’s manual may differ from the objects they represent.
E2 Lite Precautions for Safety R20UT3240EJ0300 Rev.3.00 Page 6 of 36 May.15.20 Precautions for Safety This chapter, by showing the relevant diagrammatic symbols and their meanings, describes the precautions which should be taken in order to use this product safely and properly. Be sure to read and understand this chapter before using this product. Contact us if you have any questions about the precautions described here. WARNING WARNING indicates a potentially dangerous situation that will cause death or heavy wound unless it is avoided. CAUTION CAUTION indicates a potentially dangerous situation that will cause a slight injury or a medium-degree injury or property damage unless it is avoided. To avoid a possible danger, the following diagrammatic symbols are used to call your attention. means WARNING or CAUTION. Example: CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION. Example: DISASSEMBLY PROHIBITED means A FORCIBLE ACTION. Example: UNPLUG THE POWER CABLE FROM THE RECEPTACLE.
E2 Lite Precautions for Safety R20UT3240EJ0300 Rev.3.00 Page 7 of 36 May.15.20 WARNING Warnings for AC Power Supply: Do not repair or remodel the emulator product by yourself in order to prevent danger such as an electric shock or fire and for the sake of quality assurance. For after-sale services in case of a mechanical or electrical fault, please contact your local distributor. Always switch off the Host machine and user system before connecting or disconnecting any cables or parts. Neglect of this precaution will result in getting an electric shock or will result in the emulator product or user system emitting smoke or catching fire. Also, the user program under debug will be destroyed. Make sure that the connectors on both ends of the user-system interface cable are facing the right way relative to the user-side connector on the emulator and the connector on the user system, respectively. Neglect of this precaution will result in getting an electric shock or will result in the emulator product or user system emitting smoke or catching fire. Warning for Modification: Do not modify the emulator. Personal injury due to electric shock may occur if the emulator is modified. Modifying the product will void your warranty. Warning for Installation: Do not set the emulator in water or areas of high humidity. Make sure that the product does not get wet. Spilling water or some other liquid into the product may cause un-repairable damage. Warning for Use temperature: The emulator is to be used in an environment with a maximum ambient temperature of 35°C. Care should be taken that this temperature is not exceeded.
E2 Lite Precautions for Safety R20UT3240EJ0300 Rev.3.00 Page 8 of 36 May.15.20 CAUTION Caution to Be Taken for Handling the Emulator: Exercise caution when handling the emulator. Be careful not to apply a mechanical shock. Do not touch the connector pins of the emulator and the target MCU connector pins directly. Static electricity may damage the internal circuits. When attaching and removing the cable, hold the plug of the cable and do not touch the cable. When installing the emulator, do not flex the cable excessively or pull the emulator or the board by the cable connected to it. The cable may cause a break. Do not tape the flexible cable or apply adhesives to secure the cable. The shielding material on the surface of the cable may come off. Caution to Be Taken for System Malfunctions: If the emulator malfunctions because of interference like external noise, do the following to remedy the trouble. (1) Exit the emulator debugger, and shut OFF the emulator and the user system. (2) After a lapse of 10 seconds, turn ON the power of the emulator and the user system again, then launch the emulator debugger. Caution to Be Taken for Disposal: Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation. European Union regulatory notices: The WEEE (Waste Electrical and Electronic Equipment) regulations put responsibilities on producers for the collection and recycling or disposal of electrical and electronic waste. Return of WEEE under these regulations is applicable in the European Union only. This equipment (including all accessories) is not intended for household use. After use the equipment cannot be disposed of as household waste, and the WEEE must be treated, recycled and disposed of in an environmentally sound manner. Renesas Electronics Europe GmbH can take back end of life equipment, register for this service at “http://www.renesas.eu/weee
R20UT3240EJ0300 Rev.3.00 Page 10 of 36 May.15.20 Terminology Some specific words used in this user's manual are defined below. Integrated development environment This tool provides powerful support for the development of embedded applications for Renesas microcomputers. It has an emulator debugger function allowing the emulator to be controlled from the host machine via an interface. Furthermore, it permits a range of operations from editing a project to building and debugging it to be performed within the same application. In addition, it supports version management. Emulator debugger This means a software tool that is started up from the integrated development environment, and controls the emulator and enables debugging. Programming software This means Renesas Flash Programmer that is available on the emulator. Host machine This means a personal computer used to control the emulator. Target MCU This means the MCU to be debugged. User system This means a user's application system in which the MCU to be debugged is used. User program This means the application program to be debugged.
R20UT3240EJ0300 Rev.3.00 Page 11 of 36 May.15.20 1. Outline This chapter describes the package components, the system configuration, and the specifications of the emulator functions and operating environment.
1.1 Package Components
The E2 Lite package consists of the following items. After you have unpacked the box, check if your E2 Lite contains all of these items. Table 1.1 shows the packing components for the E2 Lite. Table 1.1 Package Components for the E2 Lite Item Description Quantity E2 Lite main unit RTE0T0002LKCE00000R 1 USB interface cable A plug — mini-B plug, 1.0 m 1 14-pin user-system interface cable 14-pin flat cable, 15 cm 1
R20UT3240EJ0300 Rev.3.00 Page 12 of 36 May.15.20
1.2 System Configuration
The E2 Lite is used by connecting it to the target MCU mounted on the user system. Figure 1.1 shows the configuration of the E2 Lite system. E2 Lite Host machine USB interface cable Integrated development environment Emulator debugger User system User interface cable Figure 1.1 System Configuration of the E2 Lite (1) E2 Lite (this product) (2) USB interface cable (included) (3) 14-pin user-system interface cable (included) 20-pin to 20-pin user-system interface cable; type name: RTE0T00020KCAC0000J (separately available) 20-pin to 10-pin user-system interface cable; type name: RTE0T00020KCAC1000J (separately available) (4) User system This is your application system on which the MCU for debugging is mounted. (5) Host machine A personal computer to control the emulator by USB interface.
1.3 PC Interface
- USB Interface* USB 2.0 full speed (also connectable to USB 1.1- and USB 3.0-compatible host machines) Note: Operation with all combinations of host machine, USB device, and USB hub is not guaranteed.
R20UT3240EJ0300 Rev.3.00 Page 13 of 36 May.15.20
1.4 Specifications
Table 1.2 lists the specifications of the E2 Lite. Table 1.2 Specifications of the E2 Lite Item Description Emulator type E2 emulator Lite Type name: RTE0T0002LKCE00000R PC interface USB 2.0 (full speed) Target interface 14-pin (2.54-mm pitch) connector 20-pin (1.27-mm pitch) connector 10-pin (1.27-mm pitch) connector Power voltage for the emulator USB-bus power supply (VBUS 4.5 V min. / 500 mA max.) Power supply for the target MCU Supplied from the user system or the emulator (3.3 V: 200 mA max.*) Supported voltages for the user system Within 1.8 V to 5.5 V, and in the range of the MCU’s power supply voltage while in operation. For more information, see the additional document for user’s manual for the E1/E20 emulator or E2 emulator Lite. External dimension (main body) 96.2 mm × 52.7 mm × 17.2 mm Weight 47 g Operating temperature 5 to 35°C (no condensation) Storage temperature -10 to 60°C (no condensation) EMC EU: EN 55032 Class A, EN 55024 USA: FCC part 15 Class A Note: When 500 mA is supplied from USB VBUS
R20UT3240EJ0300 Rev.3.00 Page 14 of 36 May.15.20
1.5 Regulatory Compliance Notices
1.5.1 European Union regulatory notices
This product complies with the following EU Directives. (These directives are only valid in the European Union.) CE Certifications:
- Electromagnetic Compatibility (EMC) Directive 2014/30/EU EN 55032 Class A WARNING: This is a Class A product. This equipment can cause radio frequency noise when used in the residential area. In such cases, the user/operator of the equipment may be required to take appropriate countermeasures under his responsibility. EN 55024
- Information for traceability
- Authorized representative & Manufacturer Name: Renesas Electronics Corporation Address: TOYOSU FORESIA, 3-2-24, Toyosu, Koto-ku, Tokyo 135-0061, Japan
- Person responsible for placing on the market Name: Renesas Electronics Europe GmbH Address: Arcadiastrasse 10, 40472 Dusseldorf, Germany
- Trademark and Type name Trademark: Renesas Product name: E2 Lite Type name: RTE0T0002LKCE00000R Environmental Compliance and Certifications:
- Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU
1.5.2 United States regulatory notices
This product complies with the following EMC regulation. (This is only valid in the United States.) FCC Certifications: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
R20UT3240EJ0300 Rev.3.00 Page 15 of 36 May.15.20
1.6 E2 Lite Hardware Configuration
As shown in Figure 1.2, the E2 Lite consists of the E2 Lite main unit, a USB interface cable, and a user- system interface cable. The emulator is connectable to the host machine via a USB port compliant with USB 2.0 (Full-Speed) or USB 1.1. E2 Lite main unit User-system interface cable USB interface cable USB VCC RESET ACT E2 Lite USER I/F GND USB Figure 1.2 E2 Lite Hardware Configuration
R20UT3240EJ0300 Rev.3.00 Page 16 of 36 May.15.20
1.7 Names of the Emulator Parts
The names of the parts of the E2 Lite are given in Figure 1.3 to Figure 1.5. E2 Lite (a) Logotype The casing bears the “RENESAS E2 Lite” logotype. (b) ACTIVE LED Marked ‘ACT’. This LED indicates the operating state of the E2 Lite control software. Illuminated: The E2 Lite is connected to the emulator debugger. Blinking: The host machine has recognized the emulator. Not illuminated: The E2 Lite is not usable for some reason. (d) VCC LED Marked ‘VCC’. This LED indicates the current state of power supply to the user system. Illuminated (orange): The emulator is supplying power to the user system or external power for the user system is on. Not illuminated: The user system is not being supplied with power. (e) RESET LED Marked ‘RESET’. This LED indicates whether or not the signal on the MCU RESET pin of the user system is being enabled. Illuminated: The reset signal is enabled. Not illuminated: The reset signal is disabled. Figure 1.3 E2 Lite Top View VCC RESET ACT E2 Lite USER I/F (a) (b) (c) (d) GND USB
R20UT3240EJ0300 Rev.3.00 Page 18 of 36 May.15.20
1.8 Operating Environment
Observe the conditions listed in Table 1.3 when using the emulator. Table 1.3 Operating Environmental Conditions Item Description Temperature Operating: +5°C to +35°C Storage: –10°C to +60°C Humidity 35% RH to 80% RH, no condensation Vibration Operating: 2.45 m/s2 max. Storage: 4.9 m/s2 max. Transportation: 14.7 m/s2 max. Ambient gases No corrosive gases may be present.
R20UT3240EJ0300 Rev.3.00 Page 19 of 36 May.15.20 2. Setup
2.1 Installing Emulator Software
If you are using the E2 Lite, download and install the latest integrated development environment or flash memory programming software from the following Web site. https://www.renesas.com/e2lite_download
2.2 Connecting the E2 Lite to the Host Machine
Use the USB interface cable supplied with the product to connect the E2 Lite to the host machine as shown in Figure 2.1. For the position of each connector of the E2 Lite, refer to section 1.7, Names of the Emulator Parts. Figure 2.1 System Configuration when Connecting the E2 Lite to the Host Machine (1) Connect the A plug of the USB interface cable to the USB interface connector of the host machine. (2) Connect the mini-B plug of the USB interface cable to the USB interface connector of the E2 Lite. When you use the E2 Lite, be sure to use the USB interface cable supplied with the product. The E2 Lite is turned on by connecting the USB interface cable. Do not connect the E2 Lite to your host machine before having installed the integrated development environment or Flash Programming software you will be using. The USB driver is automatically installed. If the USB port of the host machine or the emulator to be connected is changed, the USB driver will be re- installed. E2 Lite Host machine USB interface cable
R20UT3240EJ0300 Rev.3.00 Page 20 of 36 May.15.20
2.3 Connecting the E2 Lite to the User System
Use the procedure below to connect the E2 Lite to the user system with the user-system interface cable, or to disconnect them when moving the E2 Lite or the user system. (1) Connect the user-system interface cable to the user-side connector of the E2 Lite. When connecting the user-system interface cable to the E2 Lite, check the position of the erroneous insertion prevention key to ensure that the cable is plugged in correctly. E2 Lite Figure 2.2 User-Side Connector on the E2 Lite CAUTION Notes on connector insertion and removal: When connecting or disconnecting the user-system interface cable and the emulator, grasp the connector at the end of the cable. Pulling the cable itself will damage the wiring. Also, be aware that the user-system interface cable has the direction in which it must be inserted. If the cable is connected in the wrong direction, it may be damaged. Correct example Incorrect example VCC RESET ACT E2 Lite USER I/F User-side connector GND USB
R20UT3240EJ0300 Rev.3.00 Page 22 of 36 May.15.20 CAUTION Notes on connector insertion and removal: When connecting or disconnecting the user-system interface cable and the emulator or user system, grasp the connector at the end of the cable. Pulling the cable itself will damage the wiring. Also, be aware that the user-system interface cable has the direction in which it must be inserted. If the cable is connected in the wrong direction, it may be damaged. Correct example Incorrect example
R20UT3240EJ0300 Rev.3.00 Page 23 of 36 May.15.20
2.4 Turning the Power On/Off
Turn the power of the E2 Lite and the user system following the procedure below.
2.4.1 When a Separate Power Supply is Used for the User System
<When using the emulator> (1) Check that the power is off. Check that the user system is turned off. (2) Connect the user system. Follow the instructions in "2.3 Connecting the E2 Lite to the User System" to connect the emulator and the user system with a user-system interface cable. (3) Connect the host machine and turn on the emulator. Follow the instructions in "2.2 Connecting the E2 Lite to the Host Machine" to connect the emulator and the host machine with a USB interface cable. The E2 Lite is turned on by connecting the USB interface cable. (4) Launch the emulator debugger or programming software. (5) Turn on the user system. (6) Connect the emulator debugger or programming software to the E2 Lite. The method of connection may differ with the software. <When finished using the emulator> (1) Disconnect the E2 Lite from the emulator debugger or programming software. Disconnections may differ with the software. (2) Turn off the user system. (3) Close the emulator debugger or programming software. (4) Turn off and disconnect the emulator. The E2 Lite is turned off by disconnecting from the USB interface cable. (5) Disconnect the user system. Disconnect the user-system interface cable from the user system. CAUTION Note on the User System Power Supply: While the power of the user system is on, do not turn off the host machine or unplug the USB interface cable. The user system may be damaged due to leakages current.
R20UT3240EJ0300 Rev.3.00 Page 24 of 36 May.15.20
2.4.2 When Power is Supplied to the User System from the Emulator
<When using the emulator> (1) Connect the user system. Follow the instructions in "2.3 Connecting the E2 Lite to the User System" to connect the emulator and the user system with a user-system interface cable. (2) Connect the host machine and turn on the emulator. Follow the instructions in "2.2 Connecting the E2 Lite to the Host Machine" to connect the emulator and the user system with a user-system interface cable, then turn on the emulator. (3) Launch the emulator debugger or programming software and select the setting of power supply to the user system. (4) Connect the emulator debugger or programming software to the E2 Lite. Connections may differ with the software. <When finished using the emulator> (1) Disconnect the E2 Lite from the emulator debugger or programming software. Disconnections may differ with the software. (2) Close the emulator debugger or programming software. (3) Turn off and disconnect the emulator. Disconnect the USB interface cable from the emulator, then turn off the emulator. (4) Disconnect the user-system interface cable from the user system.
R20UT3240EJ0300 Rev.3.00 Page 25 of 36 May.15.20
2.5 Connecting System Ground
The emulator's signal ground is connected to the user system's signal ground. In the emulator, the signal ground and frame ground are connected. In the user system, connect the frame ground only; do not connect the signal ground to the frame ground (Figure 2.5). If it is difficult to separate the frame ground from the signal ground in the user system, set the GND for DC power input (AC adapter) of the host machine and the frame ground of the user system as the same potential. If the GND potential is different between the host machine and the user system, an overcurrent will flow in the low-impedance GND line and thin lines might be burned. WARNING Connecting System Ground : Separate the frame ground from the signal ground at the user system. Failure to do so will result in smoke, fire, or an electric shock due to the difference in ground potential. Figure 2.5 Connecting System Ground For a debugging environment where there is a difference in potential between the GND of the user system and that of the host machine, use the isolator (R0E000010ACB10 or R0E000010ACB20) which is separately available from Renesas.
2.6 Hot plug-in
By using the optional hot-plug adapter for E1 emulators (R0E000010ACB00) which is separately sold, the hot-plug-in function which connects the E2 Lite to the user system is available while the user system is supplied with the power and in operation. For information on the hot plug-in-function, be sure to read the latest version of a user's manual provided for each MCU group. US B E2 Lite Logic Power supply Host machine Signal ground Signal ground Signal Frame ground User system Signal ground Signal Logic
E2 Lite Troubleshooting (Action in Case of an Error) R20UT3240EJ0300 Rev.3.00 Page 26 of 36 May.15.20 3. Troubleshooting (Action in Case of an Error)
3.1 How to Solve a Trouble
The following describes how to solve a trouble when any problem occurs before the emulator debugger starts after power has been supplied to the emulator and the user system. For the latest information on the emulator and emulator debugger, visit Renesas Electronics’ development environment Web site (http://www.renesas.com/tools).
3.1.1 The ACTIVE LED does not flash or light up
(1) Power is turned off This means that the E2 Lite is in an unusable state for some reason. Check the following: Whether the E2 Lite and the host machine are connected with the USB interface cable. Whether the power for the host machine is turned on.
3.1.2 Unconnectable with the debugger
(1) Check the connection between the emulator and the target MCU. For details, refer to the additional document for user’s manual for the E1/E20 emulator or E2 emulator Lite which corresponds to the target MCU. Whether the emulator and the target device are connected correctly. Whether the connected signal lines are pulled up to the power supply or down to GND properly. (2) Check to see that the target MCU is in a ready state. The operating clock of the target MCU is on (= oscillating). The target MCU is supplied with power properly. The target MCU has been reset and is ready to go.
3.2 How to Request Support
After checking the items in “Troubleshooting”, contact us from the following URL. http://www.renesas.com/contact/ For prompt response, please specify the following information: (1) Operating environment
- Name of the target device:
- Operating frequency: [MHz]
- Operating mode: [Mode] (2) Condition
- The emulator debugger starts up / does not start up
- Frequency of errors: always / frequency ( ) (3) Problem
E2 Lite Maintenance and Warranty R20UT3240EJ0300 Rev.3.00 Page 27 of 36 May.15.20 4. Maintenance and Warranty This chapter covers basic maintenance, warranty information, provisions for repair and the procedures for requesting a repair.
4.1 Maintenance
(1) If dust or dirt collects on this product, wipe it off with a dry soft cloth. Do not use thinner or other solvents because these chemicals can cause the surface coating to separate. (2) When you do not use this product for a long period, disconnect it from the power supply, host machine and user system.
4.2 Warranty
(1) We do not provide a repair service for this product. Accordingly, we cannot accept any requests for repairs. (2) In the case of replacement due to initial failure, please contact your local distributor within 30 days of the unit’s arrival. CAUTION Note on Transporting the Product: When sending your product, use the packing box and cushioning material supplied with the product when it was delivered to you and specify caution in handling (handling as precision equipment). If packing of your product is not complete, it may be damaged during transportation.
R20UT3240EJ0300 Rev.3.00 Page 28 of 36 May.15.20 Appendix A E2 Lite Self-Checking Program (SCP) This chapter gives the procedure for using the self-checking program (SCP) for the E2 Lite in fault analysis. A.1 Flow of Self-Checking Install the emulator software, the USB driver, or the E2 Lite SCP. Install the SCP and USB driver for the E2 Lite on the host machine (this step is only required first). Connect the USB interface cable*. Connect the USB interface cable to the USB connector of the host machine and the E2 Lite and turn on the power for the emulator. Initiate the E2 Lite SCP. Initiate the E2 Lite SCP. Start the TEST1 and TEST2 programs. Start the TEST1 and TEST2 programs. View the results of self-checking. If the results were normal, “PASS” will be displayed. If checking indicated a failure, “FAIL” will be displayed. In the case of “FAIL”, a further error message is also given. For the messages and their meanings, see Table A. 1. Note: Fault analysis of the hardware by using the E2 Lite SCP only works correctly when a single emulator is connected to the host machine. When two or more emulators are connected, correct operation is not guaranteed. A.2 Preparations for Self-Checking (1) The following items are required to execute the E2 Lite SCP.
- E2 Lite main unit
- USB interface cable (included in the package)
- Host machine
- E2 Lite SCP (self-checking program) Install the E2 Lite SCP to the host machine by installing an integrated development environment from Renesas (e.g. CS+) or downloading the E2 Lite SCP installer from the following Web site. https://www.renesas.com/e2lite_download The USB driver is included in the installation of the integrated development environment from Renesas (e.g. CS+ or the e2 studio). If you are using an integrated development environment not from Renesas, please contact a Renesas Electronics representative or distributor. (2) Start up the host machine. Connect the USB interface cable to the USB connector of the host machine and the E2 Lite and turn on the power for the E2 Lite. The user-system interface cable is not used.
R20UT3240EJ0300 Rev.3.00 Page 29 of 36 May.15.20 A.3 Executing the SCP (1) Execute the E2 Lite SCP (E2Lite_SCP.exe). When CS+ has been installed, open the start menu and select [Programs] -> [Renesas Electronics CS+] -> [E2 Lite Self Check Program]. If you are using any other debugger product, install the SCP by using the installer of the SCP that has been downloaded from the E2 Lite downloading site, then open the start menu and select [Programs] -> [Renesas Electronics Utilities] -> [E2 Lite Self Check Program]. Figure A.1 Starting the E2 Lite SCP (2) Click on the [START] button to start the SCP. Do not enter any value in the [CODE] textbox since it is not used at this stage. If the user-system interface cable is connected to the user system and you click on the [START] button, the following message is displayed: “Please remove the user interface cable.” If this message is displayed, disconnect the user-system interface cable from the user system and click on the [OK] button. The SCP then starts. Figure A.2 Checking the Connection of the User-System Interface Cable
R20UT3240EJ0300 Rev.3.00 Page 30 of 36 May.15.20 If the user-system interface cable is connected to the emulator when you click on the [OK] button, “FAIL” is displayed on the screen (see the figure below). Disconnect the user-system interface cable from the emulator and click on the [START] button again to start the SCP. Figure A.3 [FAIL] at the Start of Self-Checking (when the User-System Interface Cable is Connected to the Emulator)
R20UT3240EJ0300 Rev.3.00 Page 31 of 36 May.15.20 If the USB interface cable is removed from the emulator during the execution of the SCP, “FAIL” is displayed on the screen (see the figure below). Correctly connect the USB interface cable to the emulator and click on the [START] button again to start the SCP. Figure A.4 [FAIL] Display that Appears when an Error Occurs in USB I/O Processing
R20UT3240EJ0300 Rev.3.00 Page 32 of 36 May.15.20 (3) The SCP is started. “TEST1 is running.” and “TEST2 is running.” are displayed on the screen. If the emulator correctly completes TEST1 and TEST2, “TEST1: PASS” and “TEST2: PASS” are displayed on the screen. Figure A.5 Starting the SCP (4) The result is displayed when execution of the SCP is completed. “PASS” appears on the screen after result of the SCP is correct completion. “PASS” indicates that the SCP has detected no faults in the E2 Lite. Click on the [QUIT] button to end the SCP. Figure A.6 Correct Completion of the SCP
R20UT3240EJ0300 Rev.3.00 Page 33 of 36 May.15.20 If correct completion has not been obtained at the end of the SCP, the word “FAIL” is displayed, followed by an error message in the center of the window. Table A.1 lists the error messages. Figure A.7 Display for an Error Found in Self-Checking Clicking on the [LOG] button opens the file selection dialog box. Specify the location where you want the results of self-checking to be saved. The results of self-checking are saved as a text file. Table A.1 Error Messages Message Description The E2 Lite self-check has failed. The user-system interface cable is connected to the user system or the SCP has detected a fault in the E2 Lite after it was started. If the fault falls under the warranty condition stated in section 4, Maintenance and Warranty, we will replace the product for free. In other cases, please purchase a new E2 Lite since we do not offer a repair service for this product. An error occurred during USB I/O processing. The USB interface cable is removed or the SCP detected a fault in the E2 Lite during execution of the checking. Connect the USB interface cable again and re-start the SCP. If this error message appears again, it indicates the detection of a fault in the E2 Lite.
Revision History
Rev. Date Description Page Summary 1.01 Jun. 1, 2015 First Edition issued. 1.02 Mar. 15, 2016 14 Regulatory Compliance Notices were changed. 2.00 Oct. 16, 2019 12 A statement regarding the user-system interface cables (that they are separately available) was added. 13 Table 1.2: Descriptions of the 20-pin (1.27-mm pitch) and 10-pin (1.27-mm pitch) connectors were added. 14 Regulatory Compliance Notices were changed. 17 The description of the user-side connector (20 pins) was changed. 21 Table 2.1: Recommended connectors were added to the list. 22 Figure 2.4, Connecting the User-System Interface Cable to the 20-Pin Connector when the E2 Lite is to be Used, was added. 3.00 May.15.20 30 Appendix A, E2 Lite Self-Checking Program (SCP), was added.
E2 emulator Lite RTE0T0002LKCE00000R User’s Manual Publication Date: May.15.20 Rev.3.00 Published by: Renesas Electronics Corporation
User’s Manual R20UT3240EJ0300