Edition • 2023-07-21T16:34:54+02:00 Analog Signal Isolator 2-channel IMX12-AO01-2I-2I-H0/24VDC/CC The 2-channel IMX12-AO01-2I-2I-H0/24VDC/ CC signal isolator is designed to transmit the normalized current signal galvanically isolat- ed 1:1 from the non-Ex area to the Ex area. In addition to the analog signal, digital HART® communication signals can also be transmit- ted bidirectionally. Typical applications are for example the control of I/P converters or indi- cators in the Ex area. The green LED indicates operational readi- ness. The device can detect a wire break or short circuit on the field side, the input of the related channel then switches to a high impedance state. An error in the input cir- cuit causes the red LED to flash according to NE44. The device can be used in safety circuits up to SIL2 (high and low demand according to IEC 61508) and meets the requirements of NE21. It is equipped with removable spring type ter- minals. The device is equipped with removable spring-type terminals. ■ Output circuits monitored for wire-break and short-circuit ■ Complete galvanic isolation ■ HART transparent ■ Removable spring type terminals ■ ATEX, IECEx, cFM, cUL,NEPSI, IN- METRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval ■ Installation in zone 2 ■ SIL 2

Edition • 2023-07-21T16:34:54+02:00 Type IMX12-AO01-2I-2I-H0/24VDC/CC ID 7580407 Nominal voltage 24 VDC Operating voltage 10…30 VDC Power consumption ð 2.2 W Power dissipation, typical ð 1.31 W Input current 2 x 4…20 mA Reference temperature 23 °C Output circuits Output current 2 x 4…20 mA Load resistance current output ð 0.8 kò Minimum load ï 50 ò Short-circuit At a load resistance of < 30 ò, the input current is < 500 µA Wire break at a load resistance of > 30 kò the input current is < 500 µA Response characteristic Rise time (10…90 %) ð 10 ms Fall time (90…10 %) ð 10 ms Measuring accuracy (including linearity, hysteresis and repeatability) ð 0.05 % of full scale Reference temperature 23 °C Temperature drift ð 0.002 % of full scale/K Galvanic isolation Test voltage 2.5 kV RMS Input 1 to output 1 375 V peak value acc. to EN 60079-11 Input 2 to output 2 375 V peak value acc. to EN 60079-11 Input 1 to supply 150 V RMS acc. to EN 50178 and EN 61010-1 Input 2 to supply 150 V RMS acc. to EN 50178 and EN 61010-1 Output 1 to supply 375 V peak value acc. to EN 60079-11 Output 2 to supply 375 V peak value acc. to EN 60079-11 Output 1 to output 2 50 V RMS acc. to EN 50178 and EN 61010-1 Input 1 to input 2 150 V RMS acc. to EN 50178 and EN 61010-1 Important note For Ex-applications the values specified in the corre- sponding Ex certificates (ATEX, IECEx, UL, etc.) ap- ply. Ex approval acc. to conformity certificate TÜV 15 ATEX 153600 X Application area II (1) G, II (1) D Ignition protection category [Ex ia Ga] IIC; [Ex ia Da] IIIC Application area II 3 (1) G Ignition protection type Ex nA [ia Ga] IIC T4 Gc Important note If the device is used in applications to achieve func- tional safety according to IEC 61508, the safety manual must be used. Information in the data sheet are not valid for functional safety. Use in SIL safety circuits SIL 2 acc. to IEC 61508 Displays/Operating elements Operational readiness Green Error indication red Dimensions

Edition • 2023-07-21T16:34:54+02:00 Mechanical data Protection class IP20 Flammability class acc. to UL 94 V-0 Ambient temperature -25…+70 °C Storage temperature -40…+80 °C Dimensions 120 x 12.5 x 128 mm Weight 167 g Mounting instructions DIN rail (NS35) Housing material Polycarbonate/ABS Electrical connection Removable spring-type terminals, 2-pin Terminal cross-section 0.2…2.5 mm² (AWG: 24…14) Environmental conditions Operating height Up to 2000 m above sea level Pollution degree II Surge/Overvoltage cate- gory II (EN 61010-1) Standards used Voltage resistance and insulation EN 50178 EN 61010-1 EN 50155 GL VI-7-2 Shock EN 61373 class B EN 50155 GL VI-7-2 EN 60068-2-6 EN 60068-2-27 Temperature EN 60068-2-1 Ad EN 50155 GL VI-7-2 EN 60068-2-2 Bd EN 60068-2-1 Air humidity EN 60068-2-38 EMC EN 50155 GL VI-7-2 NE21 EN 61326-1 EN 61326-3-1 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 EN 61000-4-29 EN 55011 EN 55016 EN 50121-3-2 EN 61000-6-2

Edition • 2023-07-21T16:34:54+02:00 Accessories Type code Ident-No. Dimension drawing IMX12-SC-2X-4BK 7580940 Screw terminals for IM(X)12 modules; included in delivery: 4 pcs. of 2-pin black terminals IMX12-SC-2X-4BU 7580941 Screw terminals for IM(X) 12 modules; included in delivery: 4 pcs. of 2-pin blue terminals IMX12-CC-2X-4BK 7580942 Spring terminals for IM(X)12 modules; included in delivery: 4 pcs. black terminals, 2-pin IMX12-CC-2X-4BU 7580943 Spring terminals for IM(X)12 modules; included in delivery: 4 pcs. blue terminals, 2-pin