Edition • 2023-07-21T16:32:35+02:00 Solenoid Driver 2-channel IMX12-DO01-2U-2U-PR/24VDC/CC The 2-channel IMX12-DO01-2U-2U- PR/24VDC/CC solenoid driver provides an in- trinsically safe output signal limited in current and voltage. Loads in the Ex area can thus be supplied directly. Typical applications are the control of Ex i pilot valves and the powering of displays and transmitters. The device can be powered from a power bridge that also trans- mits a collective fault signal. The device is ready for operation when pow- er is applied. The green LED indicates opera- tional readiness. A yellow LED indicates the switching state of the associated output. The device can detect a wire break or short circuit when a "high" is present at the input. The input then switches to high impedance and the common alarm output becomes con- ducting. An error in the output circuit causes the red LED to flash according to NE44. The device can be used in safety circuits up to SIL2 (high and low demand according to IEC 61508) and meets the requirements of NE21. It is equipped with removable spring type ter- minals. The device is equipped with removable spring-type terminals. ■ Output circuits monitored for wire-break and short-circuit ■ Complete galvanic isolation ■ Input reverse-polarity protected ■ Removable spring type terminals ■ Power bridge (connector incl. in delivery) ■ ATEX, IECEx, cUL, cFM, INMETRO, NEP- SI, Kosha, TR CU EAC, TIIS ■ Installation in zone 2 ■ SIL 2

Edition • 2023-07-21T16:32:35+02:00 Type IMX12-DO01-2U-2U-PR/24VDC/CC ID 7580106 Nominal voltage 24 VDC Operating voltage 10…30 VDC Power consumption ð 3.5 W Power dissipation, typical ð 1.39 W 0-signal 0…5 VDC 1-signal 10…30 VDC Input delay ð 20 ms Short-circuit Output at load resistance < 30 ò , the input will be > 100 kò Wire break Output at > 20 kò load resistance, the input will be > 100 kò. Output curve Power-Bridge common alarm output MOSFET, Umax = 30 V, Imax = 100 mA Response characteristic Limit frequency ð 50 Hz Galvanic isolation Test voltage 2.5 kV RMS Input 1 to output 1 375 V peak value acc. to EN 60079-11 Input 2 to output 2 375 V peak value acc. to EN 60079-11 Input 1 to supply 300 V RMS acc. to EN 50178 and EN 61010-1 Input 2 to supply 300 V RMS acc. to EN 50178 and EN 61010-1 Output 1 to supply 375 V peak value acc. to EN 60079-11 Output 2 to supply 375 V peak value acc. to EN 60079-11 Output 1 to output 2 50 V RMS acc. to EN 50178 and EN 61010-1 Input 1 to input 2 300 V RMS acc. to EN 50178 and EN 61010-1 Important note For Ex-applications the values specified in the corre- sponding Ex certificates (ATEX, IECEx, UL, etc.) ap- ply. Ex approval acc. to conformity certificate TÜV 14 ATEX 149780X Application area II (1) G, II (1) D Ignition protection category [Ex ia Ga] IIC; [Ex ia Da] IIIC Application area II 3 (1) G Ignition protection type Ex nA [ia Ga] IIC T4 Gc Important note If the device is used in applications to achieve func- tional safety according to IEC 61508, the safety manual must be used. Information in the data sheet are not valid for functional safety. Use in SIL safety circuits SIL 2 acc. to IEC 61508 Displays/Operating elements Operational readiness Green Switching state Yellow Error indication red Dimensions

Edition • 2023-07-21T16:32:35+02:00 Mechanical data Protection class IP20 Flammability class acc. to UL 94 V-0 Ambient temperature -25…+70 °C Storage temperature -40…+80 °C Dimensions 120 x 12.5 x 128 mm Weight 161 g Mounting instructions DIN rail (NS35) Housing material Polycarbonate/ABS Electrical connection Removable spring-type terminals, 2-pin Connection variant Power bridge with collective fault signal Terminal cross-section 0.2…2.5 mm² (AWG: 24…14) Environmental conditions Operating height Up to 2000 m above sea level Pollution degree II Surge/Overvoltage cate- gory II (EN 61010-1) Standards used Voltage resistance and insulation EN 50178 EN 61010-1 EN 50155 GL VI-7-2 Shock EN 61373 class B EN 50155 GL VI-7-2 EN 60068-2-6 EN 60068-2-27 Temperature EN 60068-2-1 Ad EN 50155 GL VI-7-2 EN 60068-2-2 Bd EN 60068-2-1 Air humidity EN 60068-2-38 EMC EN 50155 GL VI-7-2 NE21 EN 61326-1 EN 61326-3-1 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 EN 61000-4-29 EN 55011 EN 55016 EN 50121-3-2 EN 61000-6-2

Edition • 2023-07-21T16:32:35+02:00 Accessories Type code Ident-No. Dimension drawing IMC 1.5/ 5-ST-3.81 BK 7580954 Power Bridge Connection Terminal MCVR 1.5/ 5-ST-3.81 BK 7580955 Power Bridge Connection Terminal MC 1.5/ 5-ST-3.81 BK 7580956 Power Bridge Connection Terminal E/ME TBUS NS35 BK 7580957 Power Bridge Connection Terminal IMX12-PS02-UI-UIR- PR/24VDC/CC

7580611 Power supply module power bridge; Collective fault signal via

relay; Single and redundant power supply via terminals; Re- movable screw terminals IMX12-SC-2X-4BK 7580940 Screw terminals for IM(X)12 modules; included in delivery: 4 pcs. of 2-pin black terminals IMX12-SC-2X-4BU 7580941 Screw terminals for IM(X) 12 modules; included in delivery: 4 pcs. of 2-pin blue terminals IMX12-CC-2X-4BK 7580942 Spring terminals for IM(X)12 modules; included in delivery: 4 pcs. black terminals, 2-pin IMX12-CC-2X-4BU 7580943 Spring terminals for IM(X)12 modules; included in delivery: 4 pcs. blue terminals, 2-pin