Edition • 2023-07-21T16:27:14+02:00 Isolating transducer 1-channel IM33-11EX-HI/24VDC The 1-channel HART isolating transducer IM33-11EX-HI/24VDC is designed to oper- ate intrinsically safe HART 2-wire transduc- ers (III) in the Ex area and to transmit the measured signal to the non-Ex area. In ad- dition to the analog signals, also the digital HART communication signals can be transmit- ted bidirectionally. Alternatively, passive 2-wire HART transmitters (II) and active 3-wire HART transmitters (I) can be operated. The device features one input and one output circuit, laid out for 0/4…20 mA. A green LED indicates operational readiness. The input signal is transmitted 1:1 without in- terference and made available at the output in the non-Ex area. The removable terminal blocks feature test sockets (Ø 2 mm) for connection of a HART handheld. ■ Power supply of 2-wire measuring trans- ducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters ■ Input circuit: 0/4…20 mA ■ Output circuit: 0/4…20 mA ■ SIL2 ■ Removable terminal blocks, screwable, with 2 mm test box ■ Complete galvanic isolation ■ Input reverse-polarity protected ■ ATEX, IECEx, UL, CFMUS, TR CU, CCEO, Kosha ■ Installation in zone 2
Edition • 2023-07-21T16:27:14+02:00 Type IM33-11EX-HI/24VDC ID 7506440 Nominal voltage 24 VDC Operating voltage 19…29 VDC Power consumption ð 2.2 W Transmitter connection Supply voltage ï 17 V / 20 mA Current 25 mA Input current 0/4...20 mA Input resistance (current) ð 250 ò Output circuits Output current 0/4…20 mA Load resistance current output ð 0.5 kò Response characteristic Rise time (10…90 %) ð 50 ms Fall time (90…10 %) ð 50 ms Measuring accuracy (including linearity, hysteresis and repeatability) ð 0.1 % of full scale Reference temperature 23 °C Temperature drift ð 0.005 % of full scale/K Galvanic isolation Test voltage 2.5 kV RMS Important note For Ex-applications the values specified in the corre- sponding Ex certificates (ATEX, IECEx, UL, etc.) ap- ply. Ex approval acc. to conformity certificate TÜV 18 ATEX 230812 X Application area II (1) G, II (1) D Ignition protection category [Ex ia Ga] IIC; [Ex ia Da] IIIC Ex approval acc. to conformity certificate TÜV 06 ATEX 552977 X Application area II 3 G Ignition protection type Ex nA [ic Gc] IIC T4 Gc Characteristic trapezoidal Important note If the device is used in applications to achieve func- tional safety according to IEC 61508, the safety manual must be used. Information in the data sheet are not valid for functional safety. Approval SIL 2 acc. to EXIDA FMEDA Use in SIL safety circuits SIL 2 acc. to IEC 61508 Displays/Operating elements Operational readiness Green Dimensions
Edition • 2023-07-21T16:27:14+02:00 Mechanical data Protection class IP20 Flammability class acc. to UL 94 V-0 Ambient temperature -25…+70 °C -25 ... +60 °C für UL, FM, TIIS Storage temperature -40…+80 °C Dimensions 110 x 18 x 110 mm Weight 170 g Mounting instructions DIN rail (NS35) or panel Housing material Polycarbonate/ABS Electrical connection 4 × 3-pin removable terminal blocks with test socket, reverse polarity protected, screw terminal Terminal cross-section 1 × 2.5 mm²/2 × 1.5 mm² Tightening torque 0.5 Nm
Edition • 2023-07-21T16:27:14+02:00 Accessories Type code Ident-No. Dimension drawing IM-CC-3X2BU/2BK 6900475 Cage clamp terminals for IM modules (Ex-devices with 18 mm overall width); includes: 2 pcs. 3-pin blue terminals and 2 pcs. 3-pin black terminals.