Features
■ 1.65V to 3.6V VCC supply operation ■ 3.6V tolerant inputs and outputs ■ tPD 2.8 ns max for 3.0V to 3.6V VCC 3.7 ns max for 2.3V to 2.7V VCC 7.4 ns max for 1.65V to 1.95V VCC ■ Power-off high impedance inputs and outputs ■ Static Drive (IOH /IOL ) ±24 mA @ 3.0V VCC ±18 mA @ 2.3V VCC ±6 mA @ 1.65V V CC ■ Uses patented Quiet Series noise/EMI reduction circuitry ■ Latchup performance exceeds 300 mA ■ ESD performance: Human body model > 2000V Machine model > 250V Ordering Code: Devices also available in Tape and Reel. Specify by appending the suffix letter “X” to the ordering code. Logic Symbol IEEE/IEC Connection Diagram Pin Descriptions Quiet Series is a trademark of Fairchild Semiconductor Corporation. Order Number Package Number Package Description 74VCX00M M14A 14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-120, 0.150” Narrow 74VCX00MTC MTC14 14-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide Pin Names Description An, Bn Inputs O n Outputs
www.fairchildsemi.com 2 74VCX00 Absolute Maximum Ratings(Note 1) Recommended Operating Conditions (Note 3) Note 1: The Absolute Maximum Ratings are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the Absolute Maximum Rat- ings. The “Recommended Operating Conditions” table will define the condi- tions for actual device operation. Note 2: I O Absolute Maximum Rating must be observed. Note 3: Floating or unused inputs must be held HIGH or LOW Supply Voltage (VCC ) −0.5V to +4.6V DC Input Voltage (VI) −0.5V to +4.6V Output Voltage (VO ) HIGH or LOW State (Note 2) −0.5V to VCC + 0.5V VCC = 0V −0.5V to +4.6V DC Input Diode Current (IIK) VI < 0V −50 mA DC Output Diode Current (IOK ) VO < 0V −50 mA VO > VCC +50 mA DC Output Source/Sink Current (IOL /IOL ) ±50 mA DC V CC or Ground Current per ±100 mA Supply Pin (ICC or Ground) Storage Temperature Range (Tstg) −65°C to +150°C Power Supply Operating 1.65V to 3.6V Data Retention Only 1.2V to 3.6V Input Voltage −0.3V to 3.6V Output Voltage (V O ) HIGH or LOW State 0V to V CC Output Current in IOH /IOL VCC = 3.0V to 3.6V ±24 mA VCC = 2.3V to 2.7V ±18 mA VCC = 1.65V to 2.3V ±6 mA Free Air Operating Temperature (TA) −40°C to +85°C Minimum Input Edge Rate (Δt/ΔV) VIN = 0.8V to 2.0V, VCC = 3.0V 10 ns/V Symbol Parameter Conditions VCC (V) Min Max Units VIH HIGH Level Input Voltage 2.7–3.6 2.0 V VIL LOW Level Input Voltage 2.7–3.6 0.8 V VOH HIGH Level Output Voltage I OH = −100 µA 2.7–3.6 V CC − 0.2 V IOH = −12 mA 2.7 2.2 IOH = −18 mA 3.0 2.4 IOH = −24 mA 3.0 2.2 VOL LOW Level Output Voltage I OL = 100 µA 2.7–3.6 0.2 V IOL = 12 mA 2.7 0.4 IOL = 18 mA 3.0 0.4 IOL = 24 mA 3.0 0.55 II Input Leakage Current 0 ≤ VI ≤ 3.6V 2.7–3.6 ±5.0 µA IOFF Power-Off Leakage Current 0 ≤ (VI, VO ) ≤ 3.6V 0 10 µA ICC Quiescent Supply Current V I = VCC or GND 2.7–3.6 20 µA ΔICC Increase in ICC per Input V IH = VCC −0.6V 2.7–3.6 750 µA
3 www.fairchildsemi.com 74VCX00 Note 4: For CL = 50 pF, add approximately 300 ps to the AC maximum specification Note 5: Skew is defined as the absolute value of the difference between the actual propagation delay for any two separate outputs of the same device. The specification applies to any outputs switching in the same direction, either HIGH-to-LOW (tOSHL ) or LOW-to-HIGH (tOSLH ). Symbol Parameter Conditions VCC (V) Min Max Units VIH HIGH Level Input Voltage 2.3–2.7 1.6 V VIL LOW Level Input Voltage 2.3–2.7 0.7 V VOH HIGH Level Output Voltage I OH = −100 µA 2.3–2.7 V CC − 0.2 V IOH = −6 mA 2.3 2.0 IOH = −12 mA 2.3 1.8 IOH = −18 mA 2.3 1.7 VOL LOW Level Output Voltage I OL = 100 µA 2.3–2.7 0.2 VIOL = 12 mA 2.3 0.4 IOL = 18 mA 2.3 0.6 II Input Leakage Current 0 ≤ VI ≤ 3.6V 2.3–2.7 ±5.0 µA IOFF Power-Off Leakage Current 0 ≤ (VI, VO ) ≤ 3.6V 0 10 µA ICC Quiescent Supply Current V I = VCC or GND 2.3–2.7 20 µA Symbol Parameter Conditions VCC (V) Min Max Units VIH HIGH Level Input Voltage 1.65–2.3 0.65 x V CC V VIL LOW Level Input Voltage 1.65–2.3 0.35 x V CC V VOH HIGH Level Output Voltage I OH = −100 µA 1.65–2.3 V CC − 0.2 V IOH = −6 mA 1.65 1.25 VOL LOW Level Output Voltage I OL = 100 µA 1.65–2.3 0.2 V IOL = 6 mA 1.65 0.3 II Input Leakage Current 0 ≤ VI ≤ 3.6V 1.65–2.3 ±5.0 µA IOFF Power-Off Leakage Current 0 ≤ (VI, VO ) ≤ 3.6V 0 10 µA ICC Quiescent Supply Current V I = VCC or GND 1.65–2.3 20 µA VCC ≤ VI ≤ 3.6V 1.65–2.3 ±20 Symbol Parameter TA = −40°C to +85°C, CL = 30pF, RL = 500Ω Min Max Min Max Min Max tPLH tOSHL Output to Output Skew (Note 5) 0.5 0.5 0.75 ns tOSLH
5 www.fairchildsemi.com 74VCX00 Physical Dimensions inches (millimeters) unless otherwise noted 14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-120, 0.150” Narrow Package Number M14A
www.fairchildsemi.com 6 74VCX00 Low Voltage Quad 2-Input NAND Gate with 3.6V Tolerant Inputs and Outputs Physical Dimensions inches (millimeters) unless otherwise noted (Continued) 14-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be rea- sonably expected to result in a significant injury to the user. 2. A critical component in any component of a life support device or system whose failure to perform can be rea- sonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com