74AC05 FAIRCHILD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

I Open drain for wired NOR function I Radiation tolerant FACT process Ordering Code: Device also available in Tape and Reel. Specify by appending suffix letter “X” to the ordering code. Logic Symbol IEEE/IEC Pin Descriptions Connection Diagram FACT  is a trademark of Fairchild Semiconductor Corporation. Order Number Package Number Package Description 74AC05SC M14A 14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150” Narrow Body Pin Names Description An Inputs O n Outputs

www.fairchildsemi.com 2 74AC05 Absolute Maximum Ratings(Note 1) Recommended Operating Conditions Note 1: Absolute maximum ratings are those values beyond which damage to the device may occur. The databook specifications should be met, with- out exception, to ensure that the system design is reliable over its power supply, temperature, and output/input loading variables. Fairchild does not recommend operation of FACT circuits outside databook specifications. Note 2: All outputs loaded; thresholds on input associated with output under test. Note 3: Maximum test duration 2.0 ms, one output loaded at a time. Note 4: IIN and ICC @ 3.0V are guaranteed to be less than or equal to the respective limit @ 5.5V VCC . Supply Voltage (VCC ) −0.5V to +7.0V DC Input Diode Current (IIK) VI = −0.5V −20 mA VI = VCC + 0.5V +20 mA DC Input Voltage (VI) −0.5V to VCC + 0.5V DC Output Diode Current (IOK ) VO = −0.5V −20 mA VO = VCC + 0.5V +20 mA DC Output Voltage (VO ) −0.5V to VCC + 0.5V DC Output Source or Sink Current (IO ) ± 50 mA DC V CC or Ground Current per Output Pin (ICC or IGND ) ± 50 mA Storage Temperature (TSTG ) −65°C to +150°C Supply Voltage (VCC ) 2.0V to 6.0V Input Voltage (VI) 0V to V CC Output Voltage (VO ) 0V to V CC Operating Temperature (TA) −40°C to +85°C Minimum Input Edge Rate (∆V/∆t) VIN from 30% to 70% of VCC VCC @ 3.3V, 4.5V, 5.5V 125 mV/ns Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units Conditions (V) Typ Guaranteed Limits 5.5 2.75 3.85 3.85 5.5 2.75 1.65 1.65 VOL Maximum LOW Level 3.0 0.002 0.1 0.1 Output Voltage 4.5 0.001 0.1 0.1 V I OUT = 50 µA 5.5 0.001 0.1 0.1 VIN = VIL or VIH 3.0 0.32 0.44 I OL = 12 mA 4.5 0.36 0.44 V I OL = 24 mA 5.5 0.36 0.44 I OL = 24 mA (Note 2) IIN (Note 4) Maximum Input Leakage Current 5.5 ±0.1 ±1.0 µAV I = VCC , GND IOHD Off-State Current 5.5 +0.5 +10.0 µAV IN = VCC IOLD Minimum Dynamic 5.5 50 75 mA V OLD = 1.65V Max Output Current (Note 3) ICC (Note 4) Maximum Quiescent Supply Current 5.5 4.0 20.0 µAV IN = VCC or GND

3 www.fairchildsemi.com 74AC05 Note 5: Voltage Range 3.3 is 3.3V ± 0.3V Voltage Range 5.0 is 5.0V ± 0.5V Note 6: AC Load is VCC x 2, RL = 1 kΩ C L = 50 pF Capacitance VCC TA = +25°C Symbol Parameter (V) C L = 50 pF T A = −40°C to +85°C Units (Note 5) Min Max Min Min ns ns Symbol Parameter Typ Units Conditions C IN Input Capacitance 4.5 pF V CC = 5.0V C PD Power Dissipation Capacitance 30.0 pF V CC = 5.0V

www.fairchildsemi.com 4 74AC05 Hex Inverter with Open Drain Outputs Physical Dimensions inches (millimeters) unless otherwise noted 14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150” Narrow Body Package Number M14A Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD ’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be rea- sonably expected to result in a significant injury to the user. 2. A critical component in any component of a life support device or system whose failure to perform can be rea- sonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com