74560 MYRRA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

FOR SWITCH MODE POWER SUPLLIES – 20 to 150 kHz MYRRA Part N° Ratio Max Pri. Current A rms Rsec. Ω max Lsec. mH min Pulse Vsec x t max Sine Vsec rms max Typical Load/ Accuracy/ Current Insulation Voltage P/ S 74560 1/ 100 10 1.1 12 300 V.µs 25 Vrms 5 – 50 Ω / 1% / 10 A 4000 V 74562 1/ 100 25 1.1 12 300 V.µs 25 Vrms 5 – 50 Ω / 1% / 25 A 4000 V 74563 1/ 700 25 55 390 2000 V.µs 50 Vrms 10 – 700 Ω / 1% / 25 A 2500 V FOR MAINS AC CURRENT MEASUREMENT - 50 to 400 Hz MYRRA Part N° Ratio Max Pri. Current A rms Rsec. Ω max Lsec. mH min Pulse Vsec x t max Sine Vsec rms max Typical Load/ Accuracy/ Current Insulation Voltage P/ S 74561 1/ 2000 8 A 400 4.5 H 5 V.ms 1 Vrms ≤ 100 Ω / 2% / 6 A 4000 V SAFETY : These products are only composed of UL approved materials. These products have a construction conform to CEI950, CEI335, CEI61558 74560, 74561 : 8 mm creepage distance (for Reinforced insulation) 74562 : 6 mm creepage distance (for Reinforced insulation) 74563 : 3 mm creepage distance (for Basic insulation) P S PCB drill @ Ø 1.1mm P S PCB drill @ Ø 1.1 & 2.2 mm