DM74174 FAIRCHILD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
■ Contains six flip-flops with single-rail outputs ■ Buffered clock and direct clear inputs ■ Individual data input to each flip-flop ■ Applications include: Buffer/storage registers Shift registers Pattern generators ■ Typical clock frequency 40 MHz ■ Typical power dissipation per flip-flop 38 mW Ordering Code: Connection Diagram Function Table (Each Flip-Flop) H = HIGH Level (steady state) L = LOW Level (steady state) X = Don't Care ↑ = Transition from LOW-to-HIGH level Q 0 = The level of Q before the indicated steady-state input conditions were established. Order Number Package Number Package Description DM74174 N16E 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide Inputs Outputs Clear Clock D Q LXXL H ↑ HH H ↑ LL HLX Q 0
www.fairchildsemi.com 2 DM74174 Logic Diagram
3 www.fairchildsemi.com DM74174 Absolute Maximum Ratings(Note 1) Note 1: The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the absolute maximum ratings. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Recommended Operating Conditions Note 2: TA = 25°C and VCC = 5V.
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted) Note 3: All typicals are at VCC = 5V, TA = 25°C. Note 4: Not more than one output should be shorted at a time. Note 5: With all outputs open and all DATA and CLEAR inputs at 4.5V, ICC is measured after a momentary ground, then 4.5V applied to the CLOCK input. Switching Characteristics at VCC = 5V and TA = 25°C Supply Voltage 7V Input Voltage 5.5V Operating Free Air Temperature Range 0°C to +70°C Storage Temperature Range −65°C to +150°C Symbol Parameter Min Nom Max Units V CC Supply Voltage 4.75 5 5.25 V VIH HIGH Level Input Voltage 2 V VIL LOW Level Input Voltage 0.8 V IOH HIGH Level Output Current −0.8 mA IOL LOW Level Output Current 16 mA fCLK Clock Frequency (Note 2) 0 30 MHz tW Pulse Width Clock LOW 25 (Note 2) Clock HIGH 10 ns Clear 20 t SU Data Setup Time (Note 2) 20 ns tH Data Hold Time (Note 2) 0 ns tREL Clear Release Time (Note 2) 30 ns TA Free Air Operating Temperature 0 70 °C Symbol Parameter Conditions Min Typ Max Units (Note 3) VI Input Clamp Voltage V CC = Min, II = −12 mA −1.5 V VOH HIGH Level V CC = Min, IOH = Max 2.4 V Output Voltage V IL = Max, VIH = Min VOL LOW Level V CC = Min, IOL = Max 0.4 V Output Voltage V IH = Min, VIL = Max II Input Current @ Max Input Voltage V CC = Max, VI = 5.5V 1 mA IIH HIGH Level Input Current V CC = Max, VI = 2.4V 40 µA IIL LOW Level Input Current V CC = Max, VI = 0.4V −1.6 mA IOS Short Circuit Output Current V CC = Max (Note 4) −18 −57 mA ICC Supply Current V CC = Max (Note 5) 45 65 mA Symbol Parameter From (Input) R L = 400Ω , CL = 15 pF Units To (Output) Min Max fMAX Maximum Clock Frequency 30 MHz tPLH Propagation Delay Time Clock to Any Q 25 ns LOW-to-HIGH Level Output tPHL Propagation Delay Time Clock to Any Q 25 ns HIGH-to-LOW Level Output tPHL Propagation Delay Time Clear to Any Q 40 ns HIGH-to-LOW Level Output
www.fairchildsemi.com 4 DM74174 Hex/Quad D-Type Flip-Flop with Clear Physical Dimensions inches (millimeters) unless otherwise noted 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide Package Number N16E Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be rea- sonably expected to result in a significant injury to the user. 2. A critical component in any component of a life support device or system whose failure to perform can be rea- sonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com