Features
■ Full decoding of input logic ■ 80 mA sink-current capability ■ All outputs are OFF for invalid BCD input conditions Ordering Code: Connection Diagram Function Table H = HIGH Level (OFF) L = LOW Level (ON) Order Number Package Number Package Description DM74145N N16E 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide No. Inputs Outputs DCBA 0123456789
0 LLLLL HHHHHHHHH
1 L L LHHLHHHHHHHH
2 L LHLHHLHHHHHHH
3 L LHHHHHLHHHHHH
4 LHL LHHHHLHHHHH
5 LHLHHHHHHLHHHH
6 LHHLHHHHHHLHHH
7 LHHHHHHHHHHLHH
8 HL L LHHHHHHHHLH
9 HL LHHHHHHHHHHL
D
www.fairchildsemi.com 2 DM74145 Logic Diagram
3 www.fairchildsemi.com DM74145 Absolute Maximum Ratings(Note 1) Note 1: The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the absolute maximum ratings. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Recommended Operating Conditions
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted) Note 2: All typicals are at VCC = 5V, TA = 25°C. Note 3: ICC is measured with all outputs open and all inputs grounded. Switching Characteristics at VCC = 5V and TA = 25°C Supply Voltage 7V Input Voltage 5.5V Operating Free Air Temperature Range 0°C to +70°C Storage Temperature Range −65°C to +150°C Symbol Parameter Min Nom Max Units V CC Supply Voltage 4.75 5 5.25 V VIH HIGH Level Input Voltage 2 V VIL LOW Level Input Voltage 0.8 V VOH HIGH Level Output Voltage 15 V IOL LOW Level Output Current 20 mA TA Free Air Operating Temperature 0 70 °C Symbol Parameter Conditions Min Typ Max Units (Note 2) VI Input Clamp Voltage V CC = Min, II = −12 mA −1.5 V ICEX HIGH Level V CC = Min, VOH = Max 250 µA Output Current V IL = Max, VIH = Min VOL LOW Level V CC = Min, IOL = Max 0.4 Output Voltage V IH = Min, VIL = Max V IOL = 80 mA 0.5 0.9 VCC = Min II Input Current @ Max Input Voltage V CC = Max, VI = 5.5V 1 mA IIH HIGH Level Input Current V CC = Max, VI = 2.4V 40 µA IIL LOW Level Input Current V CC = Max, VI = 0.4V −1.6 mA ICC Supply Current V CC = Max (Note 3) 43 70 mA Symbol Parameter Conditions Min Max Units tPLH Propagation Delay Time C L = 15 pF 30 ns LOW-to-HIGH Level Output R L = 100Ω tPHL Propagation Delay Time 30 ns HIGH-to-LOW Level Output
www.fairchildsemi.com 4 DM74145 BCD to Decimal Decoders/Drivers Physical Dimensions inches (millimeters) unless otherwise noted 16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide Package Number N16E Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be rea- sonably expected to result in a significant injury to the user. 2. A critical component in any component of a life support device or system whose failure to perform can be rea- sonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com