73VR1100 MSYSTEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 18
Technical content
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 1/18 https://www.m-system.co.jp/ Paperless Recording System PAPERLESS RECORDER (remote I/O modules) Functions & Features
- 100 msec. storing rate for the max. of 64 points (1 station) with the R3-NE1 module
- Graphic image view helps to recognize measuring points and signal status at a glance
- Data stored in CF Cards and SD Cards
- Memory card slot accessible at the front
- Real time monitoring at the host PC via Ethernet
- Dedicated application software to view and analyze the data
- Touch panel operation
- IP 65 front panel 144 (5.67) 144 (5.67) 133 (5.24) mm (inch) MODEL: 73VR1100-[1]-[2][3]
ORDERING INFORMATION
- Code number: 73VR1100-[1]-[2][3] Specify a code from below for each of [1] through [3]. (e.g. 73VR1100-E-M2/Q)
- Specify the specification for option code /Q (e.g. /C01/S01/HA) [1] LANGUAGE N: Japanese E: English [2] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (CE not available for desktop type) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [3] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel INSTALLATION /HA: Desktop type (with handle and feet) (Desktop type cannot be mounted on a panel surface. The handle and rubber feet cannot be detached.)
RELATED PRODUCTS
Please refer to data sheets for the respective models.
- PC recorder R1M, R2M, R1MS, RZMS series
- Remote I/O R3 series Ethernet (Modbus/TCP) interface module (model: R3-NE1) Modbus interface module (model: R3-NM1)
- Remote I/O R5 series Ethernet (Modbus/TCP) interface module (model: R5-NE1) Modbus interface module (model: R5-NM1)
- Modbus I/O module (model: R7M)
- Ethernet I/O module, Modbus/TCP (model: R7E) R7 configurator software (model: R7CON) To connect with R7M series, change Modbus Communication Parameters of the R7M by using R7CON and the special cable.
- Multi power monitor (model: 53U)
- Ethernet tower light (Model: IT60RE, IT40SRE, IT50SRE, IT60SRE) Lamps and buzzer are turned on/off in combination with alarm output of 73VR1100.
- Ethernet communication adaptor (model: 72EM2-M4) ■ Memory card A memory card is required to store data in the 73VR1100. Available for purchase from M-System. Consult M-System (except SD/CF conversion adapter). M-System will not guarantee the product’s described performance if a memory card other than purchased from M -System, or specified below, is used.
- CF Card 1. Manufacturer: Hagiwara Solutions Model No.: MCF10P-xxxxS Capacity: 128 MB through 1 GB (CFI-xxxxDG ... discontinued) 2. Manufacturer: Apacer Technology Model name: CFC III Model No.: AP-CFxxxxE3NR-ETNDNRQ
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 2/18 https://www.m-system.co.jp/ Capacity: 256 MB through 1 GB Part No.: 81.27L20.TB47C (256 MB) 81.29910.TB37C (512 MB) 81.29920.TB37C (1 GB) (AP-CFxxxxE3ER-ETNDNR, AP-CFxxxxE3ER-ETNDNRK ... discontinued)
- SD Card (Compatible with 73VR1100 Ver.5.03.xx or later) Manufacturer: Hagiwara Solutions Model No.: NSD6-004GH (B21SEI (NSDA-004GT, NSDA-004GL ... discontinued) SD/CF Conversion Adapter is required to use SD card. There are some restrictions on using SD card. For details, refer to the instruction manual.
- SD/CF Conversion Adapter (operation confirmed): DeLOCK adaptor CF II to SDHC,SDXC Model: 61796 (operation has been confirmed with the adapter purchased in the year of 2016.) 62637 (operation has been confirmed with the adapter purchased in the year of 2018.) Note: Refer to the data sheets of the respective models. PACKAGE INCLUDES...
- 73VR Application Software CD (model: 73VRPAC2)
- Mounting brackets (two) (/HA: Not included for desktop type) GENERAL SPECIFICATIONS Construction: Panel mount type or desktop type Degree of protection: IP65; applicable to the front panel of the recorder with single mounting according to the specified panel cutout (/HA: Desktop type cannot be mounted on a panel surface) ■ CONNECTION Power input, alarm output, RUN contact output: M3 separable screw terminal (torque 0.5 N·m) Screw terminal: Nickel-plated steel (standard) or stainless steel Ethernet: RJ-45 Modular Jack RS-485: Euro type connector terminal Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) Applicable wire size: 0.2 to 2.5 mm2 or AWG 24 to AWG 12 for both stranded and single core wires. stripped length 7 mm. Use pin terminals with stranded wires. ■ MATERIALS Enclosure: Steel Bezel: Flame-resistant resin (black) Front filter: Transparent resin Isolation: Alarm output to RUN output to power to Ethernet to FG or RS-485 ■ INDICATORS RUN output indicator LED: Green light turns on in normal conditions; off in an abnormality. Power indicator LED: Green light turns on when the power is supplied. ■ INTERFACE Ethernet: 10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE 802 (10BASE-T) or IEEE 802.3 (100BASE- TX) IP address: 192.168.0.1 (factory default setting) Subnet mask: 255.255.255.0 (factory default setting) Default gateway: None (factory default setting) CF Card slot: Type I; for use with the cards’ operating voltage 3.3 V USB: Conforms to Version 1.1 ■ DISPLAY Display device: 5.5-inch TFT LCD Display colors: 256 Resolution: 320 × 240 pixels Pixel pitch: 0.12 × 0.35 mm Note: The backlight can be replaced in M-System factory. The LCD must be replaced at the same time. ■ ALARM / RUN OUTPUT Rated load: 250 V AC @ 0.5 A (cos ø = 1) (For desktop type EU conformity: < 50 V AC) 30 V DC @ 0.5 A (resistive load) Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 250 VA or 150 W Minimum load: 1 V DC @ 1 mA Mechanical life: 2 × 107 cycles (rate 300/min.) External protection is recommended when driving an inductive load. RUN output contact: ON in normal conditions; OFF in errors (CPU error, application errors) Alarm output contact: Specified in the application software EXTERNAL INTERFACE ■ Modbus RTU Configuration: Half-duplex, asynchronous, no procedure Standard: Conforms to TIA/EIA RS-485-A Max. transmission distance: 500 meters Transfer rate: 38400 bps Data bit: 8 Parity bit: Odd Stop bit: 1 Max. node number: 15 (except the master) Transmission media: Shielded twisted-pair cable (CPEV-S φ0.9) Terminating resistor: incorporated
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 3/18 https://www.m-system.co.jp/ INSTALLATION Power input
- AC: Approx. 15 VA at 100 V Approx. 20 VA at 240 V
- DC: 8 W or 340 mA Operating temperature: 0 to 50°C (32 to 122°F) Display quality (e.g. decreased contrast) may deteriorate when the recorder is used for a long time in an environment exceeding 50°C. However, it is only a temporary phenomenon. When the recorder is back in normal temperature, full legibility is recovered. No damage in performance. Operating humidity: 30 to 85 %RH (non-condensing) Allowable dust particles: 0.1 mg/m2 (no conductive particles) Corrosive gas: Not allowed Mounting: Panel flush mounting (except desktop type) Panel cutout dimensions: 137 × 137 mm (5.39”× 5.39”) Weight: 1.7 kg (3.7 lb) Caution: Use of UPS (switching time: without delay, output: sine waveforms) is recommended to prevent data loss or CF card damage by a loss of power during recording. PERFORMANCE Calendar clock accuracy: Monthly deviation 3 minutes at 25°C Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 500 V AC @ 1 minute (alarm output to RUN output to power or FG or RS-485) AC powered:
2000 V AC @ 1 minute (power to FG or Ethernet or RS-485)
500 V AC @ 1 minute (FG or RS-485 to Ethernet)
DC powered:
1250 V AC @ 1 minute (power to FG or Ethernet or RS-485)
STANDARDS & APPROVALS EU conformity: (M2 AC power of desktop type does not conform to EU directive) EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Alarm output to RUN output to power to FG or Ethernet or RS-485: Reinforced insulation (300 V) RoHS Directive
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 4/18 https://www.m-system.co.jp/ APPLICATION SOFTWARE CD ■ 73VRPAC2 (included in the product package)
- 73VR1100 Builder Software: Model 73VR11BLD Used to configure parameters on the PC. - Parameter configurations can be downloaded to the recorder via Ethernet. - Present setting on the 73VR1100 can be uploaded and displayed on the PC. - Configuration files can be converted into CSV.
- 73VR Data Viewer: Model 73VRWV Used to show and analyze recorded data on the PC. - Data stored in the CF Card can be called up on the PC screen via the CF Card Reader. - Data stored in the CF Card can be sent by FTP and called up on the PC screen. - Various analyzing functions - Data, alarm history and comment files can be converted into CSV.
- PC Recorder Software: Model MSR128-V6 The 73VR1100 data can be sampled and stored in real time via Ethernet by the MSR128-V6.
- Instruction Manuals - 73VR1100 users manual - 73VR11BLD users manual - 73VRWV users manual - MSR128-V6 users manual PC REQUIREMENTS (provided by the user) ■ 73VR1100 Builder Software: Model 73VR11BLD Operating system Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit) Note: Proper software functions may not be ensured under certain conditions. Screen area 1024 by 768 pixels or better resolution CD drive Windows supported CD drive is used to install the software program. $BSESFBEFS 6TFEUPSFBEXSJUFUIF$'$BSE .PVTF 8JOEPXTTVQQPSUFE LAN card LAN card required to connect to Ethernet; 10BASE-T or 100BASE-T cable ■ 73VR Data Viewer: Model 73VRWV Operating system Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit) Note: Proper software functions may not be ensured under certain conditions. Screen area 1024 by 768 pixels or higher Display color 65000 colors (16-bit) Main memory (RAM) 2 GB recommended CD drive Windows supported CD drive is used to install the software program. $BSESFBEFS 6TFEUPSFBEXSJUFUIF$'$BSE .PVTF Windows supported (Certain functions of the 73VR may be compromised if the mouse’s software ESJWFSJT OPU8JOEPXTTUBOEBSE LAN card LAN card required to connect to Ethernet; 10BASE-T or 100BASE-T cable
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 5/18 https://www.m-system.co.jp/ ■ PC Recorder Software: Model MSR128-V6 NORMAL MODE (storing rates ≥ 500 ms) )*()41&&%.0%& TUPSJOHSBUFTNT PC IBM PC/AT or compatible Operating system Windows XP SP1, SP2, SP3, Windows Vista Business (32-bit), Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit) Note: Proper software functions may not be ensured under certain conditions. CPU Pentium III 800 MHz or higher
1 GHz higher for Windows Vista, Windows 7 ,
1FOUJVN*7()[PSIJHIFS Screen area 1024 by 768 pixels or better resolution Display color 65000 colors (16-bit) 7JEFPNFNPSZ .#NJOJNVN .#SFDPNNFOEFE .#NJOJNVN Main memory 256 MB recommended for Windows XP
1 GB recommended for Windows Vista, Windows 7 ,
.#SFDPNNFOEFEGPS8JOEPXT91 Hard disk area Use an internal hard disk. *2 Max. approx. 100 MB required per day. Use an internal hard disk. *2 Max. approx. 500 MB required per day. Printer Use a printer for Windows. The programs use Standard System Fonts used in Windows. Use a printer driver for Standard System Fonts. CD drive Windows supported CD drive is used to install the software program. $BSESFBEFSESJWF 6TFEXJUIEFWJDFTXIJDITBWFEBUBJOB$'$BSE Communication port RS-232-C port (COM1 through COM5) supported LAN card -"/DBSECZ8JOEPXT *1 . The 73VR1100 or the 73VR21x cannot be used in High Speed Mode. *2. External (e.g. SCSI) devices may impair appropriate performance.
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 6/18 https://www.m-system.co.jp/ EXTERNAL VIEW ■ FRONT VIEW ■ REAR VIEW (2) Front Cover (6) CF Card Access Indicator LED (7) USB Connector(3) CF Card Slot (4) Eject Button (5) Reset Button (1) Touch Panel Screen (13 ) RUN Output Terminal (9) LAN Port (14 ) Alarm Output Terminal (12 ) Power Input Terminal (11 ) Power Indicator LED (10 ) RUN Output Indicator LED (8) RS-485 Terminal Block FG DG TR DB DA FG ALM ALM U (+) V (–) RUN RUN
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 7/18 https://www.m-system.co.jp/ COMMUNICATION CABLE CONNECTIONS 73VR1100 PC Recorder 53U DA DB TR DG FG PC Recorder 53U RS-485 *1 *1 *1. Internal terminating resistor is used when the device is at the extreme end of a transmission line. *2. Install shield cables to all sections and ground them at a single point. *2FG *2FG RS-485 RS-485 RS-485 Terminator ■ PC RECORDER, 53U 73VR1100 DA DB TR DG FG *2FG Terminator ■ R3-NM1, R5-NM1, R7M DA DB DG SLD FG R3-NM1 R5-NM1 R7M DA DB DG SLD FG R3-NM1 R5-NM1 R7M Terminator CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. RJ-45 MODULAR JACK FG USB CF CARD SLOT Ethernet 10BASE-T / 100BASE-TX To I/O Devices* U (+) V (–) ALM + ALM – RUN + FG DG TR DB DA RUN – POWER *Short across these terminals when the device is at the extreme end of a transmission line.
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 8/18 https://www.m-system.co.jp/ EXTERNAL DIMENSIONS unit: mm [inch]
- Panel mount type 144 (5.67) 133 (5.24) 29.2 (1.15) 2 to 26 panel thickness (.08 to 1.02) Attach the mounting bracket either on the top/bottom or on the sides. 151.5 (5.96) 144 (5.67) 136.5 (5.37) 151.5 (5.96) 136.5 (5.37)
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 9/18 https://www.m-system.co.jp/
- Desktop type 29.2 (1.15) 144 (5.67) 136.5 (5.37) 136.5 (5.37) 173 (6.81) (.16) (.98)
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 10/18 https://www.m-system.co.jp/ PANEL CUTOUT (unit: mm) Usable panel thickness: 2 – 26 mm (0.08” – 1.02”) 137 0 137 137 ■ SINGLE MOUNTING ■ VERTICAL CLUSTERED MOUNTING (max. 3 units) ■ HORIZONTAL CLUSTERED MOUNTING L 137 175 min L L (mm)Number n 282 426 570 714 858 1002 1146 1290 1434 (114 × n) – 6 175 min Notes 1. Dimensional tolerance ±3% unless otherwise specified. (±0.3 mm for < 10 mm) 2. Desktop type cannot be mounted on a panel surface. SOFTWARE FUNCTIONS ■ NUMBER OF INPUT PEN POINTS High speed mode: 64 points Normal mode: 128 points Function pen points are included in the above figures. ■ TYPE OF I/O DEVICES High speed mode: R3-NE1 Normal mode: R1M-GH2, R1M-J3, R1M-A1, R1M-D1, R1M-P4, R1MS-GH3, R2M-2G3, R2M-2H3, RZMS-U9, R3-NE1, R3-NM1, R5-NE1, R5-NM1, R7E, R7M, 53U, IT60RE, IT40SRE, IT50SRE, IT60SRE ■ NUMBER OF I/O DEVICES Ethernet High speed mode: 1 station Normal mode: 2 stations; Max. 15 nodes are connectable to one 72EM2-M4 station. RS-485: 15 nodes ■ DATA STORING METHOD Normal: Recording is manually initiated and stopped. Data is continuously stored while the recording is on. Auto: Recording is automatically initiated and stopped at a predefined time. Event recording: The recorder detects an external event by trigger signal, and stores preset number of samples (max. 1200 respectively) before and after the moment of event. Remote trigger: Data is automatically recorded while the external trigger condition (input) is true. ■ STORING RATE High speed mode: 100 msec. Normal mode: 500 msec., 1, 2, 5, 10 seconds, 1 minute, 10
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 11/18 https://www.m-system.co.jp/ minutes (Actual storing rate depends upon the number of I/O devices. Contact M-System for more information.) [Example] Max. number of I/O devices that ensures 500 msec. storing intervals under the following conditions: Data cycle priority on alarm, RS-485 connection, no trigger or alarm setting R1M-GH2: 10 RZMS-U9: 2 R3-NE1: 1 (128 channels, analog input only) ■ DATA STORAGE Data file: Stores momentary values in the storing rate and their calculation result. Alarm history file: Records time index information when alarms are triggered and reset. Oldest data is overwritten with new data when the number of records reaches its limit. Comment history file: Records comments written in trend views with time index. Oldest data is overwritten with new data when the number of records reaches 1000 files. Configuration file: Stores the 73VR1100 setting. File format: Binary Oldest measured data is overwritten with new data or data recording is stopped when the card memory is full. ■ ALARM
- Analog Alarm Alarm setpoints: Max. 4 points per channel Alarm type: High / Low Deadband: Set in engineering unit values Output: Remote output devices
- Discrete Alarm Alarm type: ON / OFF Delay time: Selectable Output: Remote output devices
- Data Storage: Trigger time, reset time, pen number and tag name, alarm message Number of stored alarm events: Depends upon the CF Card capacity.
128 MB: 250 events
256 MB: 500 events
512 MB or 1 GB: 1000 events
■ CALCULATION FUNCTIONS Function pen points High speed mode: 32 points Normal mode: 32 or 64 points selectable Operations Arithmetic: Addition/subtraction, Multiplication, Division Logical: AND, OR, NOT, XOR Mathematical: Square root extractor, Power Accumulation: Analog accumulation, Pulse accumulation (per time unit) Filter: Moving average, First order lag Hold: Peak (maximum) hold (tracking increasing signal), Peak (minimum) hold (tracking decreasing signal) F value: F value Anemoscope (16 directions) Alarm: Alarm trip can be programmed for calculated results. ■ DATA DISPLAY FUNCTIONS
- Trend View Chart direction: Perpendicular or horizontal Number of pens displayed: 2, 4, 6, 8 per view Number of display views: 4 Chart speed:(Chart speed is described as number of pixels to plot single data sample.)(pixel(s)/samples)
- 4, 1, 1/5, 1/32
- 1/160, 1/480 or 1/960 (Not selectable with 100 msec. storing rate) Display rate:(Common setting to all views) 1, 2 or 5 sec. Pen thickness: Normal and wide Digital indicator: Shows momentary value. Alarm indicator: Shows alarm status of the channels displayed on the screen. Comment: Shows comments entered manually. Scale: Linear and square root; Switchable to the engineering unit scale.
- Bargraph View Bargraph direction: Perpendicular or horizontal Number of pens displayed: 2, 4, 6, 8 per view Number of display views: 4 Display rate:(Common setting to all views) 1, 2 or 5 sec. Digital indicator: Shows momentary value. Alarm indicator: Shows alarm status of the channels displayed on the screen. Scale: Linear and square root; Switchable to the engineering unit scale.
- Overview Number of pens displayed: 2, 4, 6, 8, 16 per view Number of display views: 64 Display rate:(Common setting to all views) 1, 2, or 5 sec. Alarm indicator: Shows alarm status and date/time of the last alarm trip and reset for the channels displayed on the screen.
- Graphic View Number of display views: 2 Display rate:(Common setting to all views) 1, 2 or 5 sec. Background image file format: .bmp Background image size: 320 by 240 pixels Background image color: 256 Number of components displayed: Max. 64 per view
- Retrieve View: Shows data stored in the CF Card. Number of pens displayed: 2, 4, 6, 8 per view
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 12/18 https://www.m-system.co.jp/ Number of display views: 4 Data search: Scrolling the chart, specifying a specific time index, or searching by max./min. values.
- Alarm History View: Shows data stored in the alarm history file. Number of displayed alarm events: 16 Number of display views: 1 Display update: Automatically updated by a new event Data search: Scrolling the view or specifying a specific time index. Jump: Scroll the view to an alarm event to show the relevant data on Retrieve View.
- Comment History View: Shows data stored in the comment history file. Number of displayed alarm events: 16 Number of display views: 1 Data search: Scrolling the view or specifying a specific time index. Jump: Scroll the view to a comment to show the relevant data on Retrieve View. ■ ETHERNET COMMUNICATION Monitoring data and setup of the 73VR1100 is possible on the PC connected via Ethernet.
- Dedicated Protocol Real time communication: Transmits specific data to a host PC installed with the PC Recorder Software (model: MSR128). Max. 2 hosts. FTP communication: Transmits data stored in the CF Card using the FTP protocol to a host PC by the 73VR Data Viewer (model: 73VRWV) installed in it. Data can be transmitted even during recording. Download, Upload: Software configurations created on the 73VR1100 Configuration Builder (model: 73VR11BLD) can be downloaded to the 73VR1100. The configuration set up on the 73VR1100 can be uploaded and displayed on the 73VR11BLD.
- Modbus Protocol Protocol: Modbus/TCP Port No.: 502 (fixed) IP address: Set on the recorder Subnet mask: Set on the recorder Default gateway: Set on the recorder Max. number of 73VR1100 connected simultaneously: 2 Supported Function Codes CODE NAME FUNCTION
01 Read Coil Status Reads DO
02 Read Input Status Reads DI
04 Read Input Register Reads Input Register
11 Fetch Communication Reads Status Word and
Event Counter Event Counter from Comm. Event Counter Exception Response CODE NAME FUNCTION
01 Illegal Function Function Not supported
02 Illegal Data Address Speci/f_i ed address does
Data storing rate 100 msec. ADDR. TYPE NAME Coil (0X) 1 Discrete output (pen 1, relay 1)
2 Discrete output (pen 1, relay 2)
3 Discrete output (pen 1, relay 3)
(Unused with discrete alarm)
4 Discrete output (pen 1, relay 4)
(Unused with discrete alarm) : : 255 Discrete output (pen 64, relay 3) (Unused with discrete alarm)
256 Discrete output (pen 64, relay 4)
(Unused with discrete alarm)
257 Discrete output
(alarm output terminal) Input 1 thr. 64 Input or function data Status (1X) (discrete) Input 1 thr. I or Input or function data Register (3X) 128 F (analog) Data storing rate 500 msec. ADDR. TYPE NAME Coil (0X) 1 Discrete output (pen 1, relay 1) (Unused with discrete alarm) (Unused with discrete alarm) : : 511 Discrete output (pen 128, relay 3) (Unused with discrete alarm)
512 Discrete output (pen 128, relay 4)
(Unused with discrete alarm)
513 Discrete output
(alarm output terminal) Input 1 thr. Input or function data Status (1X) 128 (discrete) Input 1 thr. I or Input or function data Register (3X) 256 F (analog)
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 13/18 https://www.m-system.co.jp/ ■ OTHER FUNCTIONS
- Operation Lockout With a password setting, unauthorized operations on the Trend View, Bargraph View and Overview can be locked out.
- Data File Used Volume Information A bargraph with % indication is provided on the screen to show how much percent of the data file memory has been used up. 0 – 49 % used: Green bargraph 50 – 79 % used: Amber bargraph 80 – 100 % used: Red bargraph
- Hot Swapping of the CF Card The CF Card is hot swappable: removable during data recording. However, there may be a slight disturbance in storing rate when the card is inserted.
- Screen Saver The backlight is automatically turned off if the screen is untouched for a certain time period.
- Writing/Reading Setting The recorder’s present setting can be stored in a USB flash- memory. Setting stored in the memory can be read in to the 73VR1100. ■ SELECTABLE REMOTE I/O MODULES
- PC Recorder (R1, R2, RZ) Series SIGNAL TYPE MODELS DC voltage input R1M-GH2, R1MS-GH3, R2M-2G3, RZMS-U9 Thermocouple input R1M-GH2 R1MS-GH3, R2M-2H3, RZMS-U9 DC current input R1M-GH2 R1MS-GH3, RZMS-U9 RTD input R1M-J3, RZMS-U9 Potentiometer input R1M-J3, RZMS-U9 Contact input R1M-A1 Contact output R1M-D1 Pulse input R1M-P4 Totalized pulse input R1M-P4, R1M-A1
- R3 Series Remote I/O SIGNAL TYPE MODELS DC voltage input R3-SV4, R3-SV4A, R3-SV4B, R3-SV4C, R3(Y)-SV8, R3-SV8A, R3-SV8B, R3-SV8C, R3(S/Y)-SV8N, R3-SV16N, R3Y -SV16 DC current input R3-SS4, R3(Y)-SS8, R3(S/Y)-SS8N, R3(Y)-SS16N Thermocouple input R3-TS4, R3-TS8 RTD input R3-RS4, R3(S)-RS4A, R3(Y)-RS8, R3-RS8A, R3-RS8B Universal input R3-US4 Discrete input R3(S/Y)-DA16, R3(Y)-DA16A, R3-DA16B, R3-DA32A, R3-DA64A Discrete output R3(Y)-DC16, R3-DC16A, R3-DC16B, R3-DC16C, R3-DC32A, R3-DC32C, R3-DC64A, R3-DC64C Discrete I/O R3(S)-DAC16 *, R3(S)-DAC16A * 4 – 20mA input with excitation supply R3(Y)-DS4, R3-DS8N, R3(Y)-DS8N Potentiometer input R3-MS4, R3(Y)-MS8 CT input R3-CT4 AC current input with clamp-on current sensor R3-CT4A , R3-CT4B , R3-CT4C, R3-CT8A , R3-CT8B , R3-CT8C PT input R3-PT4 Zero-phase current input R3-CZ4 AC power input R3-WT4, R3-WT4A, R3-WT4B, R3-WTU High speed pulse input R3-PA4 Speed/position input R3-PA2 Totalized pulse input R3-PA4A, R3-PA4B, R3(Y)-PA16, R3(S)-PA8 Strain gauge input R3-LC2 Alarm R3-AD4, R3-AR4, R3-AS4, R3-AS8, R3-AT4, R3-AV4, R3-AV8 Gateway R3-GC1, R3-GD1, R3-GE1, R3-GFL1, R3-GM1 * Only continuous output mode is available. ** Data range must be setup with the PC Con/f_i gurator Software R3CON and the dedicated cable.
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 14/18 https://www.m-system.co.jp/
- R5 Series Remote I/O SIGNAL TYPE MODELS DC voltage input R5-SV, R5T -SV DC current input R5-SS, R5T -SS Thermocouple input R5-TS, R5T -TS RTD input R5-RS, R5T -RS Discrete input R5-DA4, R5T -DA4, R5-DA16 Discrete output R5-DC4, R5T -DC4, R5-DC16 4 – 20 mA input with excitation supply R5-DS, R5T -DS Potentiometer input R5-MS CT input R5T -CT AC current input with clamp-on current sensor R5T -CTA*, R5T -CTB* PT input R5T -PT * Data range must be setup with the PC Con/f_i gurator Software R5CON and the dedicated cable.
- R7M Series Remote I/O* SIGNAL TYPE MODELS DC voltage/current input R7M-SV4 Thermocouple input R7M-TS4 RTD input R7M-RS4 Potentiometer input R7M-MS4 CT input R7M-CT4E Discrete input R7M-DA16 Discrete output R7M-DC16A, R7M-DC16B, R7M-DC8C Discrete input (Extension) R7M-EA8, R7M-EA16 Discrete output (Extension) R7M-EC8A, R7M-EC8B, R7M-EC16A, R7M-EC16B * Must be setup with R7X Con/f_i gurator Software and the dedi- cated cable.
- R7E Series Remote I/O SIGNAL TYPE MODELS DC voltage/current input R7E-SV4 Thermocouple input R7E-TS4 RTD input R7E-RS4 Potentiometer input R7E-MS4 CT input R7E-CT4E * Discrete input R7E-DA16 Discrete output R7E-DC16A, R7E-DC16B Discrete input (Extension) R7E-EA8, R7E-EA16 Discrete output (Extension) R7E-EC8A, R7E-EC8B, R7E-EC16A, R7E-EC16B * Must be setup with R7X Con/f_i gurator Software and the dedi- cated cable.
- Power Multimeter TYPE MODELS Power multimeter 53U * * Choose ‘Modbus’ option. Only 1 DO can be used for alarm output.
- ETHERNET Tower Light SIGNAL TYPE MODELS Discrete output IT60RE, IT40SRE, IT50SRE, IT60SRE
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 15/18 https://www.m-system.co.jp/ ■ STORABLE TIME DURATION IN 1GB CF CARD STORING RATE APPROXIMATE TIME DURATION 8 ch input 16 ch input 32 ch input 64 ch input 128 ch input 0.1 seconds 27 days, 16 hours 15 days, 8 hour 8 days, 8 hours 4 days, 8 hours --- 0.5 seconds 138 days 77 days 40 days 20 days, 16 hours 14 days 1 second 277 days 154 days 81 days, 16 hours 42 days 28 days, 8 hours 10 seconds 7 years, 222 days 4 years, 83 days 2 years, 86 days 1 years, 55 days 213 days 1 minute 10 years minimum 10 years minimum 10 years minimum 6 years, 335 days 3 years, 172 days --- : Not Applicable Note 1: Data are calculated ones, and thus not guaranteed. Note 2: Assuming 4 bytes per data per channel. Note 3: A year is calculated as 365 days. SYSTEM CONFIGURATION EXAMPLES ■ R1M, R2M, RZMS [Example 1] RS-485 PC Recorder (model: R1M-GH or R1MS-GH3) PC Recorder (model: R1M-D1) PC Recorder (model: R1M-P4) RS-485 PC Recorder (model: R1M-A1) PC Recorder (model: R1M-D1) PC Recorder (model: R1M-A1) PC Recorder (model: R1M-GH) RS-232-C Interlink / Reverse Cable PC Recorder (model: R2M) PC Recorder (model: RZMS-U9) Paperless Recorder (model: 73VR1100) [Example 2] PC Recorder (model: RZMS-U9) PC Recorder (model: RZMS-U9) PC Recorder (model: RZMS-U9) Paperless Recorder (model: 73VR1100) RS-485 Ethernet Ethernet Communication Adaptor (model: 72EM2-M4) Hub / Switch RS-485 Communication Adaptor (model: 72EM2-M4)
100 Mbps
Note 1: Use a dedicated network for the 73VR1100 and its input devices. Note 2: The sampling rate depends upon the number of devices to be connected. &5)&3/&5 36/ 4&/% '*&-% $/'( &5)&3/&5 36/ 4&/% '*&-% $/'(
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 16/18 https://www.m-system.co.jp/ ■ R3, R5 SERIES Paperless Recorder (model: 73VR1100)Ethernet Ethernet Paperless Recorder (model: 73VR1100) Hub / Switch 100 Mbps Network Module (model: R3-NM1, R5-NM1) I/O Modules I/O ModulesNetwork Module (model: R3-NE1, R5-NE1) RS-485 ■ R7M Paperless Recorder (model: 73VR1100) RS-485 Note 1: Use a dedicated network for the 73VR1100 and its input devices. Note 2: The sampling rate depends upon the number of devices to be connected for the R3 series. Note 3: Use of a switch/hub via straight type cables is recommended to connect the R3-NE1 or the R5-NE1 to the 73VR1100. Modbus I/O Module (model: R7M) ■ R7E Paperless Recorder (model: 73VR1100)Ethernet Ethernet Hub / Switch Modbus I/O Module (model: R7E) Modbus I/O Module (model: R7E)
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 17/18 https://www.m-system.co.jp/ ■ 53U Paperless Recorder (model: 73VR1100) RS-485 RS-485 (Modbus RTU) Multi Power Monitor (model: 53U) AX IN AX IN AX IN ■ IT60RE (R3 applied on input units) Ethernet Ethernet Hub Interface Module (Model: R3-NE1) Tower Light (Model: IT60RE) Paperless Recorder (model: 73VR1100)
MODEL: 73VR1100 73VR1100 SPECIFICATIONS ES-7399 Rev.24 Page 18/18 https://www.m-system.co.jp/ ■ MSR128
- I/O devices connected to RS-485 • Transferring data from the CF Card PC Recorder (model: R1M-D1) PC Recorder (model: R1M-A1) PC Recorder (model: R1M-GH) Paperless Recorder (model: 73VR1100) PC Recorder Software (model: MSR128) PC Recorder Software (model: MSR128) RS-485 Ethernet Ethernet Hub / Switch PC Recorder (model: R1M-D1) PC Recorder (model: R1M-A1) PC Recorder (model: R1M-GH) Paperless Recorder (model: 73VR1100) RS-485
- I/O devices connected to Ethernet Paperless Recorder (model: 73VR1100) PC Recorder Software (model: MSR128) Ethernet Ethernet Hub / Switch 100 Mbps Card Reader CF Card Note 1: Use a dedicated network for the 73VR1100 and its input devices. Note 2: Use of a hub/switch via straight cables is recommended to connect the 73VR1100 to the PC. Note 3: The storing intervals of 100 msec. and 200 msec. are not applicable to the above configuration. I/O ModulesNetwork Module (model: R3-NE1, R5-NE1) Specifications are subject to change without notice.