Installation and Operation Manual How to install, operate and maintain your Whirlpool® Anti-Scale System Model WHASC Point-of-entry system tested and certified by NSF International for NSF/ANSI/CAN Standard 372, and is not certified for material safety, contaminant reductions, or structural integrity by NSF International. 7401671 (Rev. A 11/8/24) W11740393A Manufactured and warranted by Water Channel Partners

2805 Dodd Road, Suite 300

Eagan, MN 55121 If you have any questions or concerns when installing, operating or maintaining your Anti-Scale System, call our toll free number: 1-866-986-3223 or visit whirlpoolwatersolutions.com When you call, please be prepared to provide the model and serial number of your product, located on the rating decal on back of the cover. Do not return unit to store

Table of Contents, Specifications & Dimensions TABLE OF CONTENTS Page *Canada working pressure limits: 1.4 - 7.0 kg/cm 2. 3" 13-7/16" 10-1/8" 33-3/4" 29-3/4" OUT IN IN - OUT SIDE VIEW FRONT VIEW TOP VIEW FIG. 1 TOP VIEW SIDE VIEW FRONT VIEW 33-3/4" (86 cm)29-3/4" (75.5 cm) 3" (7.6 cm) IN OUT IN - OUT 13-7/16" (34 cm) 10-1/8" (26 cm) DIMENSIONS Model WHASC SPECIFICATIONS Model WHASC Nominal Mineral Tank Size 8" dia. x 25" tall (20.3 x 63.5 cm) Amount of Anti-Scale Media 3 lbs. (1.36 kg) Amount of HDPE Pellets 3 lbs. (1.36 kg) Service Flow Rate 10 gpm (37.9 l/min.) Maximum Flow Rate 15 gpm (56.8 l/min.) Supply Water Pressure Limits (min./max.) 20 - 125 psi (1.4 - 8.8 kg/cm 2)* Water Temperature Limits (min./max.) 40 - 120 °F (5 - 49 °C) Questions? Call Toll Free 1-866-986-3223 or visit whirlpoolwatersolutions.com When you call, please be prepared to provide the model and serial number, located on the rating decal on back of the cover.

Your safety and the safety of others are very important. We have provided many safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING” These words mean: You can be killed or seriously injured if you don’t immediately follow instructions. You can be killed or seriously injured if you don’t follow instructions. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. In the state of Massachusetts: The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation. IMPORTANT INFORMATION = Follow the installation instructions thoroughly. Failure to install the system properly voids the war- ranty. = Before you begin installation, read this entire manual. Then obtain all the materials and tools you will need to make the installation. = Check local plumbing codes. The installation must conform to them. = Use only lead-free solder and flux for all sweat- solder connections as required by state and Do not return the Anti-Scale System to store. If you have any questions, or there are missing parts or damage, please call Toll Free 1-866-986-3223 or visit www.whirlpoolwatersolutions.com When you call, please be prepared to provide the model and serial number, located on the rating decal on back of the cover. federal codes. = Use care when handling the system. Do not turn upside down, drop, or set on sharp protrusions. = Recommended maximum allowable inlet water pressure is 125 psi (8.8 kg/cm2). Use a pressure reducing valve if necessary. = This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

HOW THE WHIRLPOOL® ANTI-SCALE SYSTEM WORKS Hard water forms “scale” deposits in plumbing. These deposits are composed of calcium carbonate (CaCO 3) and magnesium carbonate (MgCO3). As scale builds up over time, it can clog plumbing and coat the heating element in your water heater, significantly reducing its efficiency and life. Unlike a traditional water softener which uses ion exchange media to remove calcium and magnesium ions from the water, the Whirlpool ® Anti-Scale System converts them into a crystalline form that is less prone to forming scale. This system does not require water for backwashing and does not discharge water to the drain. Since the Whirlpool ® Anti-Scale System does not require the addition of salt or chemicals, it is practically maintenance free. The system may benefit from having anti-scale media added every few years, based on your water use and water conditions. INSPECT SHIPMENT The parts required to install the Whirlpool® Anti-Scale System are included with the unit. Thoroughly check the system for possible shipping damage and parts loss. Remove and discard (or recycle) all packing materials. WHERE TO INSTALL THE SYSTEM = Place the system as close as possible to the pres- sure tank (well system) or water meter (city water). = Connect the system to the main water supply pipe upstream of the water heater. Do not run hot water through the system. The temperature of water passing through the system must not be above 120°F (49°C). Damage caused by hot water is not covered by the warranty. = Do not install the system where freezing temperatures could occur. Damage caused by freezing is not covered by the warranty. = Keep outside faucets on untreated water to conserve media capacity. = Put the system in a place water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage. = If installing in an outside location, you must take the steps necessary to assure the system is as effectively sheltered from the elements, contamina- tion, vandalism, etc., as when installed indoors. = Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non-metallic parts. TOOLS, PIPE & FITTINGS, OTHER MATERIALS YOU WILL NEED = Plastic inlet and outlet fittings included with the system allow water flow equivalent to 1 inch (2.54 cm) nominal pipe. To maintain full valve flow, 1" (2.54 cm) pipes to and from the system fittings are recommended. Do not reduce the pipes to less than 3/4" (1.9 cm) size. = Use copper, brass or PEX plastic pipe and fittings. = ALWAYS install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn off water to the system for repairs if needed, but still have water available to the house pipes. PLAN HOW YOU WILL INSTALL THE SYSTEM You must first decide how to run in and out pipes to the system. Look at the house main water pipe at the point where you will connect the system. Is the pipe soldered copper, glued plastic, or threaded brass/ galvanized? What is the pipe size? Now look at the typical installation illustrations on page 5. Use them as a guide when planning your particular installation. Be sure to direct incoming, untreated water to the “UPFLOW INLET” port. Packing List Plumbing AdaptersBypass Valve FIG. 2

Typical Installation Illustrations FIG. 5 BYPASS VALVE OPERATION BYPASS (water flows to house plumbing without going through Anti-Scale System) SERVICE (water flows through Anti-Scale System, and then to house plumbing) FIG. 4FIG. 3 Model WHASC INSTALLATION USING 3-VALVE BYPASS MAIN WATER PIPE MAIN WATER PIPE Model WHASC INSTALLATION USING INCLUDED BYPASS VALVE Untreated Water IN Treated Water OUT BYPASS Valve INLET Valve OUTLET Valve UPFLOW INLET For treated water (service): -Open the inlet and outlet valves For untreated (bypass): -Close the inlet and outlet valves -Open the bypass valve Untreated Water to Outside Faucets * Included with system - Pipe and fittings supplied by installer. Bypass Valve* 1" Female NPT Pipe Adapter (2) not included UPFLOW INLET 1" Female NPT Pipe Adapter (2) not included Plumbing Adapter (2)* Plumbing Adapter (2)* NOTE: System shown without top cover for clarity.

  1. INSTALL BYPASS VALVE AND/OR PLUMBING ADAPTERS: a. If installing a single bypass valve, thread the bypass valve, with lubricated o-ring seals in place, onto the head inlet and outlet ports (See Fig. 3). Tighten the collars by hand for a leak-tight seal. - OR - b. If installing a 3-valve bypass system, thread the included plumbing adapters, with lubricated o-ring seals in place, onto the head inlet and outlet ports (See Fig. 4) Tighten the collars by hand for a leak- tight seal. 1. TURN OFF WATER SUPPLY a. Close the main water supply valve near the well pump or water meter. b. Shut off the electric or fuel supply to the water heater. c. Open high and low faucets to drain all water from the house pipes. 2. REMOVE TOP COVER: a. Unsnap the top cover from the rim by pulling back on both corners at the bottom of the rear opening. Lift off the top cover and either set it aside or hang it from the post on the rim (See Fig. 6). Post Top Cover FIG. 6 Electrical Shock Hazard Prior to installation on metallic plumbing, securely install two grounding clamps and a #4 copper wire per installation instructions. Failure to follow these instructions can result in death or electrical shock. FIG. 7 4. COLD WATER PIPE GROUNDING IMPORTANT: The house cold water pipe (metal only) is often used as a ground for the house electrical system, The 3-valve bypass type of installation, shown in Figure 4, will maintain ground continuity. If you use a plastic bypass valve at the unit, continuity is broken. To restore the ground, do the following: a. Install a #4 copper wire across the removed section of main water pipe, securely clamping it at both ends (See Figure 7) - parts not included Ground Wire (not included) Clamp (2 - not included)
  1. COMPLETE PLUMBING TO AND FROM THE SYSTEM Using the “Typical Installation Illustrations” on the previous page as a guide, observe all of the following instructions while you connect inlet and outlet plumb- ing: = Be sure incoming, untreated water is directed to the “UPFLOW INLET” port. It may be necessary to plumb a crossover if the water pipe’s flow is from right to left. = Be sure to install bypass valve(s). = If making a soldered copper installation, do all sweat soldering before connecting pipes to the included plastic adapters. Torch heat will damage plastic parts. = Use pipe joint compound on all external pipe threads. = When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread. = Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the system. 6. FLUSH PIPES AND TEST FOR LEAKS IMPORTANT: To avoid water or air pressure damage to system inner parts, be sure to do the following steps exactly as listed: a. Fully open two treated water faucets, one cold and one hot, nearby the system. b. Place bypass valve(s) into BYPASS position. On a single valve, turn both handles perpendicular to water flow (See Fig. 5). On a 3 valve system, close the inlet and outlet valves, and open the bypass valve (See Fig. 4). c. Fully open the house main water pipe shutoff valve. Observe a steady flow from both opened faucets. d. Close both faucets. e. Check your plumbing work for leaks and, if any are found, fix right away. Be sure to observe all instruc- tions in the previous section, “Complete Plumbing to and from the System”. f. Turn on the gas or electric supply to the water heater. Light the pilot, if applicable. 7. START UP PROCEDURE a. Place bypass valve(s) into SERVICE position, EXACTLY as follows: = Single Bypass Valve: Turn the outlet (marked downflow inlet on head) handle parallel to water flow. Slowly turn the upflow inlet handle parallel to water flow, pausing several times to allow the system to pressurize slowly. = 3 Valve Bypass: Fully close the bypass valve and open the outlet valve. Slowly open the inlet valve, pausing several times to allow the system to pressurize slowly. b. Check all connections for leaks. c. Fully open a cold water faucet, downstream from the system, and allow 50 gallons (190 liters) of water to pass through the system. This should take at least 20 minutes. Close the faucet. d. Snap the top cover back in place on top of the rim.

PROCEDURE FOR ADDING ANTI-SCALE MEDIA 1. Remove the top cover as described on page 6. 2. Bypass the system by turning both bypass handles perpendicular to the flow of water (See Fig. 8). 3. Slowly loosen the installation collars between the bypass valve and in/out head (See Fig. 9), allowing pressure to escape from system. 4. When both installation collars between bypass and in/out head are completely loosened from the in/out head, pull the system away from the bypass valve. 5. Holding the tank neck adapter with a strap wrench, unscrew the in/out head from the tank neck adapter (See Fig. 10). Once the in/out head is completely unscrewed, check to see whether the riser pipe (See Fig. 10) is still inserted in the in/out head. Remove it by lifting the in/out head enough to grasp the riser pipe and pull it free from the head. 6. Using a hose or tube that is 3/4" (1.9 cm) O.D. or less, siphon the water from the mineral tank through the riser pipe. This will keep the top- bedding HDPE from floating out of the tank as the water rises when adding media. 7. Remove clips and clamps (See Fig. 11), and lift tank neck adaptor and top distributor from the tank neck. Be sure not to lose the o-rings. 8. Plug, cap or tape the open top of the riser pipe (See Fig. 11) to keep media from entering the riser pipe. IMPORTANT: Media entering the riser pipe will restrict fow and increase system pressure drop significantly. 9. Use a funnel that either fits around the riser pipe or alongside of it and fits inside of the tank neck. 10. Add anti-scale media to the tank. Systems are shipped from the factory with 3 lbs. (1.36 kg) of media. Replacement media is supplied in 1.5 lb. (0.68 kg) containers (P/N 7353755). 11. Uncover the riser pipe and reassemble the system in reverse order, making sure that all o-rings are in place. NOTE: The riser pipe (See Fig. 10) may have been pulled up from the bottom of the mineral tank. If this has happened, the in/out head may not engage the threads of the neck adapter. To correct this, apply air or water pressure to the riser pipe. This will move the media at the bottom of the tank, allowing the riser pipe to be lowered to the bottom of the mineral tank. FIG. 8 Turn handles to bypass FIG. 9 Bypass Valve In/Out Head Unscrew collars to remove FIG. 10 Tank Neck Adapter Unscrew In/Out Head to remove Riser Pipe FIG. 11 Lift out Top Distributor with O-Ring Riser Pipe Disengage Clips & Clamps Tank Neck Adapter Add Media through Tank Neck

No. Part No. Description 1 7351753 Head, In/Out 2 7346805 Bypass Valve Assembly, includes o-rings (See Key No. 4) 3 7346790 Adapter, Plumbing, 1" NPT, pack of 2, includes o-rings (See Key No. 4) 4 7337597 O-Ring, 1-1/16" x 1-5/16", pack of 4 5 7342788 Adapter, Tank Neck – 7331177 Tank Neck Clamp Kit (includes 2 ea. of Key Nos. 6 & 7) 6 á Clamp Section 7 á Retainer, Clamp – 7112963 Distributor O-Ring Kit (includes Key Nos. 8 & 9) 8 á O-Ring, 2-7/8" x 3-1/4" 9 á O-Ring, 2-3/4" x 3" 10 7077870 Top Distributor 11 7105047 Repl. Bottom Distributor 12 7264037 Repl. Mineral Tank, 8" x 25" 7353755 Anti-Scale Media, 1.5 lbs. (3 lbs. provided in WHASC) 7351761 HDPE Pellets, 3 lbs. (3 lbs. provided in WHASC) 14 7401689 Top Cover (order decal below) 15 7401697 Faceplate Decal 16 7290101 Rim 17 7296296 Shroud 18 7352822 Adapter, Plumbing, 1-1/4" NPT, pack of 2, includes o-rings Ù 19 7352830 Adapter, Plumbing, 1-1/4" & 1-1/2" PVC Solvent, pack of 2, incl. o-rings Ù SYSTEM PARTS LISTSYSTEM EXPLODED VIEW Ù Optional parts, not included with system. Questions? Call Toll Free 1-866-986-3223 or visit whirlpoolwatersolutions.com When you call, please be prepared to provide the model and serial number, located on the rating decal on back of the cover.

ANTI-SCALE SYSTEM WARRANTY - MODEL WHASC (except anti-scale media) Warrantor: Water Channel Partners, 2805 Dodd Road, Suite 300, Eagan, MN 55121 Warrantor guarantees, to the original purchaser when the product is purchased from an authorized dealer, and when installed and maintained in accordance with the instructions, that: One Year Full Warranty:

  • For a period of one (1) year from the date the product is delivered, all parts will be free from defects in materials and workmanship and will perform in accordance with their written specifications. Limited Warranties:
  • For a period of ten (10) years from the date the product is delivered, the fiberglass mineral tank, excluding filtration media, will not rust, corrode, leak, burst, or in any other manner, fail to perform in accordance with its written specifications.
  • For a period of three (3) years from the date the product is delivered, the in/out head will be free of defects in materials and workmanship and will perform in accordance with its written specifications. If, during such respective period, a part proves to be defective, Warrantor will ship a replacement part, directly to your home, without charge. If a repair or replacement part is unavailable, Warrantor may refund the original purchase price. If you have questions regarding a warranted product, need assistance with installation or troubleshooting, wish to order a part or report a warranty issue, we are just a phone call away. SIMPLY DIAL 1-866-986-3223 for assistance. General Provisions The above warranties are effective provided the water treatment system is operated at water pressures not exceeding 125 psi (8.8 kg/cm 2), and at water temperatures not exceeding 120°F (49°C); provided further that the water treatment system is not subject to abuse, misuse, alteration, neglect, freezing, accident or negligence; and provided further that the water treatment system is not damaged as the result of any force of nature such as, but not limited to, flood, hurricane, tornado or earthquake. The limited warranty does not cover damage due to: (a) transportation, (b) storage, (c) improper use, (d) failure to follow the product instructions or to perform any preventive maintenance, (e) modifications, (f) unauthorized repair, (g) normal wear and tear, or (h) external causes such as accidents, abuse, or other actions or events beyond Warrantor’s reasonable control. Use of aftermarket, used, or non-manufacturer provided parts will void all warranties. Warranty does not cover failures due to improper product installation. Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials shortages, or other circumstances beyond its control. THERE ARE NO WARRANTIES ON THE WATER TREATMENT SYSTEM BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND BEYOND THE ABOVE PERIODS. THE SOLE OBLIGATION OF WARRANTOR UNDER THESE WARRANTIES IS TO REPLACE OR REPAIR THE COMPONENT OR PART WHICH PROVES TO BE DEFECTIVE WITHIN THE SPECIFIED TIME PERIOD, AND WARRANTOR IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. NO DEALER, AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND THE WARRANTIES EXPRESSLY DESCRIBED ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer-owned installations only. ® / ™ © 2024 Whirlpool. All rights reserved. Manufactured under license by Water Channel Partners, Eagan, Minnesota. Limited warranty provided by manufacturer. W11740393A