Technical content
Figure 1. NI myRIO-1900
1 NI myRIO-1900
3 Power Input Cable
4 USB Device Cable
5 USB Host Cable (Not Included in Kit)
7 Mini System Port (MSP) Screw-Terminal
8 Audio In/Out Cables (One Included in Kit)
2 | ni.com | NI myRIO-1900 User Guide and Specifications Safety Information Caution Do not operate the hardware in a manner not specified in this document and in the user documentation. Misuse of the hardware can result in a hazard. You can compromise the safety protection if the hardware is damaged in any way. If the hardware is damaged, return it to National Instruments for repair. Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and free from contaminants before returning it to service. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in commercial locations. There is no guarantee that harmful interference will not occur in a particular installation or when the product is connected to a test object. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution This product was tested for EMC compliance using myRIO application software. The maximum length for USB cables is 2.0 m (6.6 ft), and the maximum length for signal wires is 30.0 cm (11.8 in.). Caution The mounting keyholes on the back of the NI myRIO-1900 are sensitive to electrostatic discharge (ESD). When handling the device, be careful not to touch inside the keyholes.
to a host computer over USB and wireless 802.11b,g,n. The following figure shows the arrangement and functions of NI myRIO-1900 components. Figure 2. NI myRIO-1900 Hardware Block Diagram
and using signals. The following figure and table show the signals on MXP connectors A and B. Note that some pins carry secondary functions as well as primary functions. Figure 3. Primary/Secondary Signals on MXP Connectors A and B
Table 1. Descriptions of Signals on MXP Connectors A and B +5V DGND Output +5 V power output. Channels section for more information. AGND N/A N/A Reference for analog input and output. +3.3V DGND Output +3.3 V power output. electrically identical to DIO lines. electrically identical to DIO lines.
that some pins carry secondary functions as well as primary functions. Figure 4. Primary/Secondary Signals on MSP Connector C Table 2. Descriptions of Signals on MSP Connector C +15V/-15V AGND Output +15 V/-15 V power output. Channels section for more information. and +15 V/-15 V power output. +5V DGND Output +5 V power output.
inputs are multiplexed to a single analog-to-digital converter (ADC) that samples all channels. ±10 V . The audio inputs are left and right stereo line-level inputs with a ±2.5 V full-scale range. reducing noise, go to ni.com/info and enter the Info Code analogwiring. Table 3. Descriptions of Signals on Audio Connectors
10 | ni.com | NI myRIO-1900 User Guide and Specifications Converting Raw Data Values to Voltage You can use the following equations to convert raw data values to volts: V = Raw Data Value * LSB Weight LSB Weight = Nominal Range ÷ 2ADC Resolution where Raw Data Value is the value returned by the FPGA I/O Node, LSB Weight is the value in volts of the increment between data values, Nominal Range is the absolute value in volts of the full, peak-to-peak nominal range of the channel, and ADC Resolution is the resolution of the ADC in bits. (ADC Resolution = 12)
- For AI and AO channels on the MXP connectors, LSB Weight = 5 V ÷ 212 = 1.221 mV Maximum reading = 4095 * 1.221 mV = 4.999 V
- For AI and AO channels on the MSP connectors, LSB Weight = 20 V ÷ 212 = 4.883 mV Maximum Positive Reading = +2047 * 4.883 mV = 9.995 V Maximum Negative Reading = -2048 * 4.883 mV = -10.000 V
- For Audio In/Out, LSB Weight = 5 V ÷ 212 = 1.221 mV Maximum Positive Reading = +2047 * 1.221 mV = 2.499 V Maximum Negative Reading = -2048 * 1.221 mV = -2.500 V
- For the accelerometer, LSB Weight = 16 g ÷ 212 = 3.906 mg Maximum Positive Reading = +2047 * 3.906 mg = +7.996 g Maximum Negative Reading = -2048 * 3.906 mg = -8.000 g DIO Lines The NI myRIO-1900 has 3.3 V general-purpose DIO lines on the MXP and MSP connectors. MXP connectors A and B have 16 DIO lines per connector. On the MXP connectors, each DIO line from 0 to 13 has a 40 kΩ pullup resistor to 3.3 V, and DIO lines 14 and 15 have 2.1 kΩ pullup resistors to 3.3 V. MSP connector C has eight DIO lines. Each MSP DIO line has a 40 kΩ pulldown resistor to ground. DGND is the reference for all the DIO lines. You can program all the lines individually as inputs or outputs. Secondary digital functions include Serial Peripheral
12 | ni.com | NI myRIO-1900 User Guide and Specifications Using the Reset Button Pressing and releasing the Reset button restarts the processor and the FPGA. Pressing and holding the Reset button for 5 seconds, then releasing it, restarts the processor and the FPGA and forces the NI myRIO-1900 into safe mode. In safe mode, the NI myRIO-1900 launches only the services necessary for updating configuration and installing software. When the NI myRIO-1900 is in safe mode, you can communicate with it by using the UART lines on MXP connector A. You need the following items to communicate with the myRIO device over UART:
- USB-to-TTL serial UAR T converter cable (for example, part number TTL-232RG-VSW3V3-WE from FTD Chip)
- Serial-port terminal p rogram configured with the following settings: – 115,200 bits per second – Eight data bits – No parity – One stop bit – No flow control Using the Wireless Button and LED For information about using the Wireless button, go to ni.com/info and enter the Info Code myriowirelessbutton. For information about using the Wireless LED, go to ni.com/info and enter the Info Code myriowirelessled. Using Button0 Button0 produces a logic TRUE when depressed and a logic FALSE when not depressed. Button0 is not debounced.
power supply connected to the device is adequate. seconds, as shown in Table 4. You can use LEDs 0 to 3 to help debug your application or easily retrieve application status. Logic TRUE turns an LED on and logic FALSE turns an LED off. supports Basler ace USB3 cameras. /V, /W, or /X drive, starting with the /U drive if it is available. Table 4. Status LED Indications occurs when an attempt to upgrade the software is interrupted. Reinstall software on the device. 3 The device is in safe mode.
4 The software has crashed twice without rebooting or cycling
out of memory. Review your RT VI and check the memory usage. Modify the VI as necessary to solve the memory usage issue.
Figure 10. NI myRIO-1900 Dimensions, Front
Figure 16. Mounting the NI myRIO-1900 Using the Key Holes Figure 17. Installing the Panel Mounting Kit on the NI myRIO-1900
1 Install three Unified #4 or M3 screws in the flat surface using the key hole dimensions of the
spacing of 2.8 mm (0.11 in.) between the flat surface and the screw heads. 2 Place the NI myRIO-1900 on the screw heads. 3 Slide the NI myRIO-1900 down to secure the key holes on the screw heads.
1 Place the panel on the back of the NI myRIO-1900
2 Slide the panel up to line up the screw holes on the panel and the NI myRIO-1900.
Figure 18. Dimensions of NI myRIO-1900 with Panel Mounting Kit
nonvolatile memory, go to ni.com/info and enter the Info Code SSDBP. Table 5. Accessories Available from NI
NI myRIO-1900 User Guide and Specifications | © National Instruments | 21 USB Ports Analog Input MXP connectors
1 MΩ powered on and idle
4.7 kΩ powered off MSP connector 4.7 kΩ powered off Working voltage Audio input single-ended channels
22 | ni.com | NI myRIO-1900 User Guide and Specifications Analog Output Aggregate maximum update rates All AO channels on MSP connector MXP connectors MSP connector Audio output two AC-coupled, single-ended channels
2 Hz to >50 kHz into high-impedance load
one UART.RX and one UART.TX line per connector input or output output
NI myRIO-1900 User Guide and Specifications | © National Instruments | 23 Input logic levels Output logic levels Output high voltage, VOH Output low voltage, VOL Maximum frequencies for secondary digital functions UART lines Accelerometer Power Output +5 V power output +3.3 V power output
24 | ni.com | NI myRIO-1900 User Guide and Specifications +15 power output -15 V power output Maximum combined power from +15 V Power Requirements NI myRIO-1900 requires a power supply connected to the power connector. Environmental To meet these specifications, you must operate the NI myRIO-1900 with the window facing away from the mounting surface and ensure that there is at least 1 in. of clearance in front of the window during use. Ambient temperature near device Storage temperature Indoor use only. Physical Characteristics Safety Safety Standards This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA 61010-1
NI myRIO-1900 User Guide and Specifications | © National Instruments | 25 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Caution Using the NI myRIO-1900 in a manner not described in this document may impair the protection the NI myRIO-1900 provides. Hazardous Locations The NI myRIO-1900 is not certified for use in hazardous locations. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55022 (CISPR 22): Gr oup 1, Class A emissions
- EN 55011 (CISPR 11): Gr oup 1, Class A emissions
- AS/NZS CISPR 11: Gr oup 1, Class A emissions
- AS/NZS CISPR 22: Gr oup 1, Class A emissions
- FCC 47 CFR Part 15B : Class A emissions
- ICES-001: Class A emissions Note For EMC declarations and certifications, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives as follows:
- 2006/95/EC; Low-V oltag e Directive (safety)
- 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
- 1999/5/EC; Radio and Telecommuni cations Terminal Equipment Directive (R&TTE) Online Product Certification To obtain product certifications and the Declaration of Conformity (DoC) for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and
26 | ni.com | NI myRIO-1900 User Guide and Specifications directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment, visit ni.com/environment/ weee. Regulatory Information United States FCC Radio Exposure The radiated output power of this device is below the FCC radio frequency exposure limits. Nevertheless, this device should be used in such a manner that the potential for human contact during normal operation is minimized. This device has been evaluated for and shown compliant with the FCC RF Exposure limits under mobile exposure conditions (antennas are greater than 20 cm from a person’s body). This device cannot be co-located with any other transmitter unless approved by FCC. This product does not contain any user serviceable components. Any unauthorized product changes or modifications will invalidate the warranty and all applicable regulatory certifications and approvals. ⊩ ˄Ё RoHS˅ Ёᅶ᠋ National InstrumentsՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)Ѣ National Instruments ЁRoHSᙃˈ䇋ⱏᔩ ni.com/ environment/rohs_chinaDŽ(For information about China RoHS compliance, go to ni.com/environment/rohs_china.) धᖯ RoHS ߟ ni.com/environment/rohs_taiwan (For i/g374/g296/g381/g396/g373/g258/g415/g381/g374/g3/g258/g271/g381/g437/g410/g3/g100/g258/g349/g449/g258/g374/g3/g90/g381/g44/g94/g3/g272/g381/g373/g393/g367/g349/g258/g374/g272/g286/g853/g3/g336/g381/g3/g410/g381 ni.com/environment/rohs_taiwan) ہRoHS (ᖯ RoHS) R39957 RoHS
NI myRIO-1900 User Guide and Specifications | © National Instruments | 27 FCC Interference Statement This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer's instruction manual, may cause interference with radio and television reception. This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This wireless adapter generates, uses, and can radiate radio frequency energy. If the wireless adapter is not installed and used in accordance with the instructions, the wireless adapter may cause harmful interference to radio communications. There is no guarantee, however, that such interference will not occur in a particular installation. If this wireless adapter does cause harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by taking one or more of the following measures:
- Reorient or relocate the receiv ing antenna of the equipment experiencing the interference.
- Increase the distance between the wireless adapter and the equ ipment experiencing the interference.
- Connect the equipment to an out let on a circuit different from which the receiver is connected.
- Consult the dealer or an experi enced radio/TV technician for help. Canada Industry Canada (IC) Notices This product complies with Industry Canada RSS-210. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, the radio transmitter(s) in this device may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
28 | ni.com | NI myRIO-1900 User Guide and Specifications Avis d’Industry Canada (IC) Cet appareil est conforme aux norme RSS210 d’Industrie Canada. Cet appareil est conforme aux normes d'exemption de licence RSS d’Industry Canada. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement. Conformément aux réglementations d'Industry Canada, les émetteurs radio de cet appareil ne peuvent fonctionner qu’à l’aide d'une antenne dont le type et le gain maximal (ou minimal) pour ces émetteurs – transmetteurs sont approuvés par Industry Canada. Pour réduire le risque d’interférence éventuelle pour les autres utilisateurs, le type et le gain de l’antenne doivent être choisis de manière à ce que la puissance isotrope rayonnée équivalente (p.i.r.e.) minimale nécessaire à une bonne communication soit fournie.
NI myRIO-1900 User Guide and Specifications | © National Instruments | 29 EU Regulatory Statements Česky [Czech] National Instruments tímto prohlašuje, že tento NI myRIO-1900 je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Dansk [Danish] Undertegnede National Instruments erklærer herved, at følgende udstyr NI cDAQ-1900 overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch [German] Hiermit erklärt National Instruments, dass sich das Gerät NI myRIO-1900 in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian] Käesolevaga kinnitabNational Instruments seadme NI myRIO-1900 vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English Hereby, National Instruments, declares that this NI myRIO-1900 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español [Spanish] Por medio de la presente National Instruments declara que el NI myRIO-1900 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική [Greek] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ National Instruments ΔΗΛΩΝΕΙ ΟΤΙ NI myRIO-1900 ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ. Français [French] Par la présente National Instruments déclare que l'appareil NI myRIO-1900 est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Italiano [Italian] Con la presente National Instruments dichiara che questo NI myRIO-1900 è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski [Latvian] Ar šo National Instruments deklarē, ka NI myRIO-1900 atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Lietuvių [Lithuanian] Šiuo National Instruments deklaruoja, kad šis NI myRIO-1900 atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlands [Dutch] Hierbij verklaart National Instruments dat het toestel NI myRIO-1900 in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Malti [Maltese] Hawnhekk, National Instruments, jiddikjara li dan NI myRIO-1900 jikkonforma mal-htigijiet essenzjali u ma provvedimenti ohrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Magyar [Hungarian] Alulírott, National Instruments nyilatkozom, hogy a NI myRIO-1900 megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
30 | ni.com | NI myRIO-1900 User Guide and Specifications Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Polski [Polish] Niniejszym National Instruments. oświadcza, że NI myRIO-1900 jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. Português [Portuguese] National Instruments declara que este NI myRIO-1900 está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Slovensko [Slovenian] National Instruments izjavlja, da je ta NI myRIO-1900 v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. Slovensky [Slovak] National Instruments týmto vyhlasuje, že NI myRIO-1900 spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish] National Instruments vakuuttaa täten että NI myRIO-1900 tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Svenska [Swedish] Härmed intygar National Instruments att denna NI myRIO-1900 står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Íslenska [Icelandic] Hér með lýsir National Instruments yfir því að NI myRIO-1900 er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC. Norsk [Norwegian] National Instruments erklærer herved at utstyret NI myRIO-1900 er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.
NI myRIO-1900 User Guide and Specifications | © National Instruments | 31 Singapore Taiwan R.O.C. Mexico La operación de este equipo está sujeta a las siguientes dos condiciones: 1) es posible que este equipo o dispositivo no cause interferencia perjudicial y 2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su propia operación no deseada. Brazil Brasil-Aviso da Anatel Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Warranty For customers other than private individual users in the EU: The NI myRIO-1900 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. For private individual users in the EU: Based on your statutory rights, National Instruments will—through its distributor—cure defects in materials and workmanship within two years from delivery. Complies with IDA Standards DA105692 低功率電波輻性電機管理辦法 第十二條經型式認證合格之低功率射頻電機,非經許可,公司、商號或使 用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發 現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信規定作業之無線電信。低功率射頻電機須忍受合法通信 或工業、科學及醫療用電波輻射性電機設備之干擾。 在 頻帶內操作之無線資訊傳輸設備僅適於室內使用 2078-13-9228 (01)07898909336299 *0107898909336299*
© 2013–2018 National Instruments. All rights reserved. 376047D-01 Jun18 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.