DLP3010LC TI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 44

Technical content

DLP3010LC 0.3 720p Digital Micromirror Device

1 Features

  • 0.3-Inch (7.93-mm) diagonal micromirror array – 1280 × 720 array of aluminum micrometer- sized mirrors, in an orthogonal layout – 5.4 – micron micromirror pitch – ±17° micromirror tilt (relative to flat surface) – Side illumination for optimal efficiency and optical engine size – Polarization independent aluminum micromirror surface
  • 8-Bit SubLVDS input data bus
  • Dedicated DLPC3478 display and light controller and DLPA200x or DLPA300x PMIC/LED driver for reliable operation

2 Applications

  • Integrated display and 3D depth capture – Smart phone, tablets, laptop, camera – Battery-powered mobile accessory
  • 3D depth capture: 3D camera, 3D reconstruction, AR/VR, dental scanner
  • 3D machine vision: robotics, metrology, in-line inspection (AOI)
  • 3D biometrics: facial and finger print recognition
  • Light exposure: 3D printers, programmable spatial and temporal light exposure

3 Description

The 7212-313BK digital micromirror device (DMD) is a digitally controlled micro-opto-electromechanical system (MOEMS) spatial light modulator (SLM). When coupled to an appropriate optical system, the DMD displays a very crisp and high quality image or video. This DMD is a component of the chipset comprising the DMD, DLPC3478 display and light controller, and DLPA200x/DLPA300x PMIC/LED driver. The compact physical size of this DMD coupled with the controller and the PMIC/LED driver provides a complete system solution that enables small form factor, low power, and high-resolution, light-control applications like such as 3D scanners. Device Information(1) PART NUMBER PACKAGE BODY SIZE (NOM) 7212-313BK FQK (57) 18.20-mm × 7.00-mm (1) For all available packages, see the orderable addendum at the end of the data sheet. 7212-313BK 0.3 720p Chipset DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA.

6.10 Physical Characteristics of the Micromirror Array...17

7.5 Optical Interface and System Image Quality

11.3 Receiving Notification of Documentation Updates.. 37

12 Mechanical, Packaging, and Orderable

4 Revision History

NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision B (May 2022) to Revision C (July 2023) Page Changes from Revision A (November 2021) to Revision B (May 2022) Page DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

2 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

5 Pin Configuration and Functions

Figure 5-1. FQK Package 57-Pin LGA (Bottom View) Table 5-1. Pin Functions – Connector Pins(1) PIN TYPE SIGNAL DATA RATE DESCRIPTION PACKAGE NET LENGTH(2) (mm)NAME NO. DATA INPUTS D_N(0) C9 I SubLVDS Double Data, Negative 10.54 D_P(0) B9 I SubLVDS Double Data, Positive 10.54 D_N(1) D10 I SubLVDS Double Data, Negative 13.14 D_P(1) D11 I SubLVDS Double Data, Positive 13.14 D_N(2) C11 I SubLVDS Double Data, Negative 14.24 D_P(2) B11 I SubLVDS Double Data, Positive 14.24 D_N(3) D12 I SubLVDS Double Data, Negative 14.35 D_P(3) D13 I SubLVDS Double Data, Positive 14.35 D_N(4) D4 I SubLVDS Double Data, Negative 5.89 D_P(4) D5 I SubLVDS Double Data, Positive 5.89 D_N(5) C5 I SubLVDS Double Data, Negative 5.45 D_P(5) B5 I SubLVDS Double Data, Positive 5.45 D_N(6) D6 I SubLVDS Double Data, Negative 8.59 D_P(6) D7 I SubLVDS Double Data, Positive 8.59 D_N(7) C7 I SubLVDS Double Data, Negative 7.69 D_P(7) B7 I SubLVDS Double Data, Positive 7.69 DCLK_N D8 I SubLVDS Double Clock, Negative 8.10 DCLK_P D9 I SubLVDS Double Clock, Positive 8.10 CONTROL INPUTS LS_WDATA C12 I LPSDR(1) Single Write data for low speed interface. 7.16 LS_CLK C13 I LPSDR Single Clock for low-speed interface 7.89 DMD_DEN_ARSTZ C14 I LPSDR Asynchronous reset DMD signal. A low signal places the DMD in reset. A high signal releases the DMD from reset and places it in active mode. LS_RDATA C15 O LPSDR Single Read data for low-speed interface POWER (3) VBIAS C1 Power Supply voltage for positive bias level at micromirrorsVBIAS C18 Power www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 3 Product Folder Links: DLP3010LC

Table 5-1. Pin Functions – Connector Pins(1) (continued) PIN TYPE SIGNAL DATA RATE DESCRIPTION PACKAGE NET LENGTH(2) (mm)NAME NO. VOFFSET D1 Power Supply voltage for HVCMOS core logic. Supply voltage for stepped high level at micromirror address electrodes. Supply voltage for offset level at micromirrors. VOFFSET D17 Power VRESET B1 Power Supply voltage for negative reset level at micromirrors.VRESET B18 Power VDD B6 Power VDD B10 Power VDD B19 Power VDD C6 Power Supply voltage for LVCMOS core logic. Supply voltage for LPSDR inputs. Supply voltage for normal high level at micromirror address electrodes. VDD C10 Power VDD C19 Power VDD D2 Power VDD D18 Power VDD D19 Power VDDI B2 Power Supply voltage for SubLVDS receivers. VDDI C2 Power VDDI C3 Power VDDI D3 Power VSS B3 Ground Common return. Ground for all power. VSS B4 Ground VSS B8 Ground VSS B12 Ground VSS B13 Ground VSS B14 Ground VSS B15 Ground VSS B16 Ground VSS B17 Ground VSS C4 Ground VSS C8 Ground VSS C16 Ground VSS C17 Ground VSS D14 Ground VSS D15 Ground VSS D16 Ground (1) Low speed interface is LPSDR and adheres to the Electrical Characteristics and AC/DC Operating Conditions table in JEDEC Standard No. 209B, Low Power Double Data Rate (LPDDR) JESD209B. (2) Net trace lengths inside the package: Relative dielectric constant for the FQK ceramic package is 9.8. Propagation speed = 11.8 / sqrt (9.8) = 3.769 inches/ns. Propagation delay = 0.265 ns/inch = 265 ps/inch = 10.43 ps/mm. (3) The following power supplies are all required to operate the DMD: VSS, VDD, VDDI, VOFFSET, VBIAS, VRESET. DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

4 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

Table 5-2. Pin Functions – Test Pads NUMBER SYSTEM BOARD A13 Do not connect A14 Do not connect A15 Do not connect A16 Do not connect A17 Do not connect A18 Do not connect E13 Do not connect E14 Do not connect E15 Do not connect E16 Do not connect E17 Do not connect E18 Do not connect www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 5 Product Folder Links: DLP3010LC

6 Specifications

6.1 Absolute Maximum Ratings

See (1) MIN MAX UNIT Supply voltage VDD Supply voltage for LVCMOS core logic(2) Supply voltage for LPSDR low speed interface –0.5 2.3 V VDDI Supply voltage for SubLVDS receivers(2) –0.5 2.3 V VOFFSET Supply voltage for HVCMOS and micromirror electrode(2) (3) –0.5 11 V VBIAS Supply voltage for micromirror electrode(2) –0.5 19 V VRESET Supply voltage for micromirror electrode(2) –15 0.5 V | VDDI–VDD | Supply voltage delta (absolute value)(4) 0.3 V | VBIAS–VOFFSET | Supply voltage delta (absolute value)(5) 11 V | VBIAS–VRESET | Supply voltage delta (absolute value)(6) 34 V Input voltage Input voltage for other inputs LPSDR(2) –0.5 VDD + 0.5 V Input voltage for other inputs SubLVDS(2) (7) –0.5 VDDI + 0.5 V Input pins | VID | SubLVDS input differential voltage (absolute value)(7) 810 mV IID SubLVDS input differential current 10 mA Clock frequency ƒclock Clock frequency for low speed interface LS_CLK 130 MHz ƒclock Clock frequency for high speed interface DCLK 560 MHz Environmental TARRAY and TWINDOW Temperature – operational (8) –20 90 °C Temperature – non-operational(8) –40 90 °C TDP Dew Point Temperature - operating and non-operating (non-condensing) 81 °C |TDELTA| Absolute Temperature delta between any point on the window edge and the ceramic test point TP1(9) 30 °C (1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime. (2) All voltage values are with respect to the ground terminals (VSS). The following power supplies are all required to operate the DMD: VSS, VDD, VDDI, VOFFSET, VBIAS, and VRESET. (3) VOFFSET supply transients must fall within specified voltages. (4) Exceeding the recommended allowable absolute voltage difference between VDDI and VDD may result in excessive current draw. (5) Exceeding the recommended allowable absolute voltage difference between VBIAS and VOFFSET may result in excessive current draw. (6) Exceeding the recommended allowable absolute voltage difference between VBIAS and VRESET may result in excessive current draw. (7) This maximum input voltage rating applies when each input of a differential pair is at the same voltage potential. Sub-LVDS differential inputs must not exceed the specified limit or damage may result to the internal termination resistors. (8) The highest temperature of the active array (as calculated by the Section 7.6) or of any point along the Window Edge as defined in Figure 7-1. The locations of thermal test points TP2 and TP3 in Figure 7-1 are intended to measure the highest window edge temperature. If a particular application causes another point on the window edge to be at a higher temperature, that point should be used. (9) Temperature delta is the highest difference between the ceramic test point 1 (TP1) and anywhere on the window edge as shown in Figure 7-1. The window test points TP2 and TP3 shown in Figure 7-1 are intended to result in the worst case delta. If a particular application causes another point on the window edge to result in a larger delta temperature, that point should be used. DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

6 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

6.2 Storage Conditions

applicable for the DMD as a component or non-operational in a system MIN MAX UNIT TDMD DMD storage temperature –40 85 °C TDP-AVG Average dew point temperature, (non-condensing)(1) 24 °C TDP-ELR Elevated dew point temperature range, (non-condensing)(2) 28 36 °C CTELR Cumulative time in elevated dew point temperature range 6 Months (1) The average over time (including storage and operating) that the device is not in the elevated dew point temperature range. (2) Exposure to dew point temperatures in the elevated range during storage and operation should be limited to less than a total cumulative time of CTELR.

6.3 ESD Ratings

V(ESD) Electrostatic discharge Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000 V (1) JEDEC document JEP155 states that 500 V HBM allows safe manufacturing with a standard ESD control process.

6.4 Recommended Operating Conditions

over operating free-air temperature range (unless otherwise noted)(1) (2) (3) MIN NOM MAX UNIT SUPPLY VOLTAGE RANGE(4) VDD Supply voltage for LVCMOS core logic Supply voltage for LPSDR low-speed interface 1.65 1.8 1.95 V VDDI Supply voltage for SubLVDS receivers 1.65 1.8 1.95 V VOFFSET Supply voltage for HVCMOS and micromirror electrode(5) 9.5 10 10.5 V VBIAS Supply voltage for mirror electrode 17.5 18 18.5 V VRESET Supply voltage for micromirror electrode –14.5 –14 –13.5 V |VDDI–VDD| Supply voltage delta (absolute value)(6) 0.3 V |VBIAS–VOFFSET| Supply voltage delta (absolute value)(7) 10.5 V |VBIAS–VRESET| Supply voltage delta (absolute value)(8) 33 V CLOCK FREQUENCY ƒclock Clock frequency for low speed interface LS_CLK(9) 108 120 MHz ƒclock Clock frequency for high speed interface DCLK(10) 300 600 MHz Duty cycle distortion DCLK 44% 56% SUBLVDS INTERFACE(10) | VID | SubLVDS input differential voltage (absolute value) Figure 6-9, Figure 6-10 150 250 350 mV VCM Common mode voltage Figure 6-9, Figure 6-10 700 900 1100 mV VSUBLVDS SubLVDS voltage Figure 6-9, Figure 6-10 575 1225 mV ZLINE Line differential impedance (PWB/trace) 90 100 110 Ω ZIN Internal differential termination resistance Figure 6-11 80 100 120 Ω 100-Ω differential PCB trace 6.35 152.4 mm www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 7 Product Folder Links: DLP3010LC

6.4 Recommended Operating Conditions (continued)

over operating free-air temperature range (unless otherwise noted)(1) (2) (3) MIN NOM MAX UNIT ENVIRONMENTAL TARRAY Array Temperature – long-term operational(11) (12) (13) (14) 0 40 to 70(13) Array Temperature - short-term operational, 25 hr max(12) (15) –20 –10 Array Temperature - short-term operational, 500 hr max(12) (15) –10 0 Array Temperature – short-term operational, 500 hr max(12) (15) 70 75 |TDELTA | Absolute Temperature difference between any point on the window edge and the ceramic test point TP1 (16) 15 °C TWINDOW Window temperature – operational(11) (17) 90 °C TDP-AVG Average dew point temperature (non-condensing)(18) 24 °C TDP-ELR Elevated dew point temperature range (non-condensing)(19) 28 36 °C CTELR Cumulative time in elevated dew point temperature range 6 Months ILLUMINATION ILLUV Illumination power at wavelengths < 410 nm(11) 10 mW/cm2 ILLVIS Illumination power at wavelengths ≥ 410 nm and ≤ 800 nm(21) 26.1 W/cm2 ILLIR Illumination power at wavelengths > 800 nm 10 mW/cm2 ILLBLU Illumination power at wavelengths ≥ 410 nm and ≤ 475 nm(21) 8.3 W/cm2 ILLBLU1 Illumination power at wavelengths ≥ 410 nm and ≤ 445 nm(21) 1.5 W/cm2 ILLθ Illumination marginal ray angle(20) 55 deg (1) Section 6.4 are applicable after the DMD is installed in the final product. (2) The functional performance of the device specified in this datasheet is achieved when operating the device within the limits defined by the Section 6.4. No level of performance is implied when operating the device above or below the Section 6.4 limits. (3) The following power supplies are all required to operate the DMD: VSS, VDD, VDDI, VOFFSET, VBIAS, and VRESET. (4) All voltage values are with respect to the ground pins (VSS). (5) VOFFSET supply transients must fall within specified maximum voltages. (6) To prevent excess current, the supply voltage delta |VDDI – VDD| must be less than specified limit. (7) To prevent excess current, the supply voltage delta |VBIAS – VOFFSET| must be less than specified limit. (8) To prevent excess current, the supply voltage delta |VBIAS – VRESET| must be less than specified limit. (9) LS_CLK must run as specified to ensure internal DMD timing for reset waveform commands. (10) Refer to the SubLVDS timing requirements in Section 6.7. (11) Simultaneous exposure of the DMD to the maximum Section 6.4 for temperature and UV illumination will reduce device lifetime. (12) The array temperature cannot be measured directly and must be computed analytically from the temperature measured at test point 1 (TP1) shown in Figure 7-1 and the Package Thermal Resistance using Section 7.6. (13) Per Figure 6-1, the maximum operational array temperature should be derated based on the micromirror landed duty cycle that the DMD experiences in the end application. Refer to Section 7.8 for a definition of micromirror landed duty cycle. (14) Long-term is defined as the usable life of the device. (15) Short-term is the total cumulative time over the useful life of the device. (16) Temperature delta is the highest difference between the ceramic test point 1 (TP1) and anywhere on the window edge shown in Figure 7-1. The window test points TP2 and TP3 shown in Figure 7-1 are intended to result in the worst case delta temperature. If a particular application causes another point on the window edge to result in a larger delta temperature, that point should be used. (17) Window temperature is the highest temperature on the window edge shown in Figure 7-1. The locations of thermal test points TP2 and TP3 in Figure 7-1 are intended to measure the highest window edge temperature. If a particular application causes another point on the window edge to result in a larger delta temperature, that point should be used. (18) The average over time (including storage and operating) that the device is not in the elevated dew point temperature range. (19) Exposure to dew point temperatures in the elevated range during storage and operation should be limited to less than a total cumulative time of CTELR. (20) The maximum marginal ray angle of the incoming illumination light at any point in the micromirror array, including Pond of Micromirrors (POM), should not exceed 55 degrees from the normal to the device array plane. The device window aperture has not necessarily been designed to allow incoming light at higher maximum angles to pass to the micromirrors, and the device performance has not been tested nor qualified at angles exceeding this. Illumination light exceeding this angle outside the micromirror array (including POM) will contribute to thermal limitations described in this document, and may negatively affect lifetime. (21) The maximum allowable optical power incident on the DMD is limited by the maximum optical power density for each wavelength range specified and the micromirror array temperature (TARRAY). DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

8 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

Micromirror Landed Duty Cycle Operational (°C) 0/100 5/95 10/90 15/85 20/80 25/75 30/70 35/65 40/60 45/55 D001 100/0 95/5 90/10 85/15 80/20 75/25 70/30 65/35 60/40 55/45 Max Recommended Array Temperature – Figure 6-1. Maximum Recommended Array Temperature (Derating Curve) www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 9 Product Folder Links: DLP3010LC

6.5 Thermal Information

THERMAL METRIC(1) DLP3010LC UNITFQK (LGA)

57 PINS

Thermal resistance Active area to test point 1 (TP1)(1) 5.4 °C/W (1) The DMD is designed to conduct absorbed and dissipated heat to the back of the package. The cooling system must be capable of maintaining the package within the temperature range specified in the Section 6.4. The total heat load on the DMD is largely driven by the incident light absorbed by the active area; although other contributions include light energy absorbed by the window aperture and electrical power dissipation of the array. Optical systems should be designed to minimize the light energy falling outside the window clear aperture since any additional thermal load in this area can significantly degrade the reliability of the device.

6.6 Electrical Characteristics

Over operating free-air temperature range (unless otherwise noted)(10) PARAMETER TEST CONDITIONS(2) MIN TYP MAX UNIT CURRENT IDD Supply current: VDD(3) (5) VDD = 1.95 V 60.5 mA VDD = 1.8 V 54 IDDI Supply current: VDDI(3) (5) VDDI = 1.95 V 16.5 mA VDD = 1.8 V 11.3 IOFFSET Supply current: VOFFSET(4) (6) VOFFSET = 10.5 V 2.2 mA VOFFSET = 10 V 1.5 IBIAS Supply current: VBIAS(4) (6) VBIAS = 18.5 V 0.6 mA VBIAS = 18 V 0.3 IRESET Supply current: VRESET(6) VRESET = –14.5 V 2.4 mA VRESET = –14 V 1.7 POWER(1) PDD Supply power dissipation: VDD(3) (5) VDD = 1.95 V 118 mW VDD = 1.8 V 97.2 PDDI Supply power dissipation: VDDI(3) (5) VDDI = 1.95 V 32 mW VDD = 1.8 V 20 POFFSET Supply power dissipation: VOFFSET(4) (6) VOFFSET = 10.5 V 23 mW VOFFSET = 10 V 15 PBIAS Supply power dissipation: VBIAS(4) (6) VBIAS = 18.5 V 11 mW VBIAS = 18 V 6 PRESET Supply power dissipation: VRESET(6) VRESET = –14.5 V 35 mW VRESET = –14 V 24 PTOTAL Supply power dissipation: Total 162.2 219 mW LPSDR INPUT(7) VIH(DC) DC input high voltage(9) 0.7 × VDD VDD + 0.3 V VIL(DC) DC input low voltage(9) –0.3 0.3 × VDD V VIH(AC) AC input high voltage(9) 0.8 × VDD VDD + 0.3 V VIL(AC) AC input low voltage(9) –0.3 0.2 × VDD V ∆VT Hysteresis ( VT+ – VT– ) Figure 6-12 0.1 × VDD 0.4 × VDD V IIL Low–level input current VDD = 1.95 V; VI = 0 V –100 nA IIH High–level input current VDD = 1.95 V; VI = 1.95 V 100 nA LPSDR OUTPUT(8) VOH DC output high voltage IOH = –2 mA 0.8 × VDD V VOL DC output low voltage IOL = 2 mA 0.2 × VDD V DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

10 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

6.6 Electrical Characteristics (continued)

Over operating free-air temperature range (unless otherwise noted)(10) PARAMETER TEST CONDITIONS(2) MIN TYP MAX UNIT CAPACITANCE CIN Input capacitance LPSDR ƒ = 1 MHz 10 pF Input capacitance SubLVDS ƒ = 1 MHz 10 pF COUT Output capacitance ƒ = 1 MHz 10 pF CRESET Reset group capacitance ƒ = 1 MHz; (720 × 160) micromirrors 200 220 pF (1) The following power supplies are all required to operate the DMD: VSS, VDD, VDDI, VOFFSET, VBIAS, VRESET. (2) All voltage values are with respect to the ground pins (VSS). (3) To prevent excess current, the supply voltage delta |VDDI – VDD| must be less than specified limit. (4) To prevent excess current, the supply voltage delta |VBIAS – VOFFSET| must be less than specified limit. (5) Supply power dissipation based on non–compressed commands and data. (6) Supply power dissipation based on 3 global resets in 200 µs. (7) LPSDR specifications are for pins LS_CLK and LS_WDATA. (8) LPSDR specification is for pin LS_RDATA. (9) Low-speed interface is LPSDR and adheres to the Electrical Characteristics and AC/DC Operating Conditions table in JEDEC Standard No. 209B, Low-Power Double Data Rate (LPDDR) JESD209B. (10) Device electrical characteristics are over Section 6.4 unless otherwise noted.

6.7 Timing Requirements

Device electrical characteristics are over Section 6.4 unless otherwise noted. MIN NOM MAX UNIT LPSDR tr Rise slew rate(1) (30% to 80%) × VDD, Figure 6-3 1 3 V/ns tƒ Fall slew rate(1) (70% to 20%) × VDD, Figure 6-3 1 3 V/ns tr Rise slew rate(2) (20% to 80%) × VDD, Figure 6-4 0.25 V/ns tƒ Fall slew rate(2) (80% to 20%) × VDD, Figure 6-4 0.25 V/ns tc Cycle time LS_CLK, Figure 6-2 7.7 8.3 ns tW(H) Pulse duration LS_CLK high 50% to 50% reference points, Figure 6-2 3.1 ns tW(L) Pulse duration LS_CLK low 50% to 50% reference points, Figure 6-2 3.1 ns tsu Setup time LS_WDATA valid before LS_CLK ↑, Figure 6-2 1.5 ns t h Hold time LS_WDATA valid after LS_CLK ↑, Figure 6-2 1.5 ns tWINDOW Window time(1) (4) Setup time + Hold time, Figure 6-2 3 ns tDERATING Window time derating(1) (4) For each 0.25 V/ns reduction in slew rate below 1 V/ns, Figure 6-6 0.35 ns SubLVDS tr Rise slew rate 20% to 80% reference points, Figure 6-5 0.7 1 V/ns tƒ Fall slew rate 80% to 20% reference points, Figure 6-5 0.7 1 V/ns tc Cycle time DCLK, Figure 6-7 1.79 1.85 ns tW(H) Pulse duration DCLK high 50% to 50% reference points, Figure 6-7 0.79 ns tW(L) Pulse duration DCLK low 50% to 50% reference points, Figure 6-7 0.79 ns tsu Setup time D(0:3) valid before DCLK ↑ or DCLK ↓, Figure 6-7 t h Hold time D(0:3) valid after DCLK ↑ or DCLK ↓, Figure 6-7 www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 11 Product Folder Links: DLP3010LC

6.7 Timing Requirements (continued)

Device electrical characteristics are over Section 6.4 unless otherwise noted. MIN NOM MAX UNIT tWINDOW Window time Setup time + Hold time, Figure 6-7, Figure 6-8 0.3 ns tLVDS- ENABLE+REFGEN Power-up receiver(3) 2000 ns (1) Specification is for LS_CLK and LS_WDATA pins. Refer to LPSDR input rise slew rate and fall slew rate in Figure 6-3. (2) Specification is for DMD_DEN_ARSTZ pin. Refer to LPSDR input rise and fall slew rate in Figure 6-4. (3) Specification is for SubLVDS receiver time only and does not take into account commanding and latency after commanding. (4) Window time derating example: 0.5-V/ns slew rate increases the window time by 0.7 ns, from 3 to 3.7 ns. LS_CLK 50% LS_WDATA 50% tw(H) tw(L) tC tWINDOW| tSU| tH| Low-speed interface is LPSDR and adheres to the Section 6.6 and AC/DC Operating Conditions table in JEDEC Standard No. 209B, Low Power Double Data Rate (LPDDR) JESD209B. Figure 6-2. LPSDR Switching Parameters LS_CLK and LS_WDATA VDD Voltage (%) tR Time VIH(AC) VIL(AC) VIH(DC) VIL(DC) tF 100 Figure 6-3. LPSDR Input Slew Rate DMD_DEN_ARSTZ VDD Voltage (%) tR Time VIL(AC) tF 100 Figure 6-4. LPSDR Input Slew Rate DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

12 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

50% 50% tC tWINDOW (1) ¼ tC| ¼ tC| DCLK_P DCLK_N D_P(0:7) D_N(0:7) (1) High-speed training scan window (2) Refer to Section 7.3.3 for details Figure 6-8. High-Speed Training Scan Window DCLP_P, D_P(0:7) DCLP_N, D_N(0:7) SubLVDS Receiver VID VIP VIN (VIP + VIN) 2VCM = VCM Figure 6-9. SubLVDS Voltage Parameters VID VLVDS(max) VLVDS(min) VCM 1.255 V 0.575 V Figure 6-10. SubLVDS Waveform Parameters VSubLVDS(max) = VCM(max) + ½ × |VID(max)| VSubLVDS(min) = VCM(min) – ½ × |VID(max)| DCLP_P, D_P(0:7) DCLP_N, D_N(0:7) Internal Termination ESD ESD SubLVDS Receiver Figure 6-11. SubLVDS Equivalent Input Circuit DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

14 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

LS_CLK and LS_WDATA VCC18 Voltage (%) 'VT VIH VIL VT+ VT± Time Figure 6-12. LPSDR Input Hysteresis LS_RDATA LS_WDATA LS_CLK Stop Start Acknowledge tPD Figure 6-13. LPSDR Read Out CL Tester channelDevice pin output under test Timing specification reference point See Section 7.3.4 for more information. Figure 6-14. Test Load Circuit for Output Propagation Measurement

6.8 Switching Characteristics(1)

Over operating free-air temperature range (unless otherwise noted). PARAMETER TEST CONDITIONS MIN TYP MAX UNIT tPD Output propagation, Clock to Q, rising edge of LS_CLK input to LS_RDATA output. Figure 6-13 CL = 5 pF 11.1 ns CL = 10 pF 11.3 ns CL = 85 pF 15 ns Slew rate, LS_RDATA 0.5 V/ns Output duty cycle distortion, LS_RDATA 40% 60% (1) Device electrical characteristics are over Section 6.4 unless otherwise noted. www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 15 Product Folder Links: DLP3010LC

6.9 System Mounting Interface Loads

PARAMETER MIN NOM MAX UNIT Maximum system mounting interface load to be applied to the: Electrical Interface Area (see Figure 6-15) 125 N Clamping and Thermal Interface Area (see Figure 6-15) 67 N Electrical Interface Area

125 N Maximum

Clamping and Thermal Interface Area # 1

33.5 N Maximum

Clamping and Thermal Interface Area # 2 Figure 6-15. System Interface Loads DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

16 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

6.10 Physical Characteristics of the Micromirror Array

Number of active columns See Figure 6-16 1280 micromirrors Number of active rows See Figure 6-16 720 micromirrors Micromirror (pixel) pitch See Figure 6-17 5.4 µm Micromirror active array width Micromirror pitch × number of active columns; see Figure 6-16 6.912 mm Micromirror active array height Micromirror pitch × number of active rows; see Figure 6-16 3.888 mm Micromirror active border Pond of micromirror (POM)(1) 20 micromirrors/ side (1) The structure and qualities of the border around the active array includes a band of partially functional micromirrors called the POM. These micromirrors are structurally and/or electrically prevented from tilting toward the bright or ON state, but still require an electrical bias to tilt toward OFF. 1280 × 720 mirrorsIllumination Width . Height Mirror 0 Mirror 1 Mirror 2 Mirror 3 Mirror 3 Mirror 2 Mirror 1 Mirror 0 Mirror 1279 Mirror 1278 Mirror 1277 Mirror 1276 Mirror 716 Mirror 717 Mirror 718 Mirror 719 Figure 6-16. Micromirror Array Physical Characteristics Figure 6-17. Mirror (Pixel) Pitch www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 17 Product Folder Links: DLP3010LC

6.11 Micromirror Array Optical Characteristics

PARAMETER TEST CONDITIONS MIN NOM MAX UNIT Micromirror tilt angle DMD landed state(1) 17 degree Micromirror tilt angle tolerance(2) (3) (4) (5) –1.4 1.4 degree Micromirror tilt direction (6) (7) Landed ON state 180 degree Landed OFF state 270 Micromirror crossover time(8) Typical performance 1 3 µs Micromirror switching time(9) Typical performance 10 Image performance(10) Bright pixel(s) in active area (11) Gray 10 Screen (12) 0 micromirrors Bright pixel(s) in the POM (13) Gray 10 Screen (12) 1 Dark pixel(s) in the active area (14) White Screen 4 Adjacent pixel(s) (15) Any Screen 0 Unstable pixel(s) in active area (16) Any Screen 0 (1) Measured relative to the plane formed by the overall micromirror array. (2) Additional variation exists between the micromirror array and the package datums. (3) Represents the landed tilt angle variation relative to the nominal landed tilt angle. (4) Represents the variation that can occur between any two individual micromirrors, located on the same device or located on different devices. (5) For some applications, it is critical to account for the micromirror tilt angle variation in the overall system optical design. With some system optical designs, the micromirror tilt angle variation within a device may result in perceivable non-uniformities in the light field reflected from the micromirror array. With some system optical designs, the micromirror tilt angle variation between devices may result in colorimetry variations, system efficiency variations, or system contrast variations. (6) When the micromirror array is landed (not parked), the tilt direction of each individual micromirror is dictated by the binary contents of the CMOS memory cell associated with each individual micromirror. A binary value of 1 results in a micromirror landing in the ON state direction. A binary value of 0 results in a micromirror landing in the OFF state direction. See Figure 6-18. (7) Micromirror tilt direction is measured as in a typical polar coordinate system: Measuring counter-clockwise from a 0° reference which is aligned with the +X Cartesian axis. (8) The time required for a micromirror to nominally transition from one landed state to the opposite landed state. (9) The minimum time between successive transitions of a micromirror. (10) Conditions of Acceptance: All DMD image quality returns will be evaluated using the following projected image test conditions: Test set degamma shall be linear Test set brightness and contrast shall be set to nominal The diagonal size of the projected image shall be a minimum of 20 inches The projections screen shall be 1X gain The projected image shall be inspected from a 38 inch minimum viewing distance The image shall be in focus during all image quality tests (11) Bright pixel definition: A single pixel or mirror that is stuck in the ON position and is visibly brighter than the surrounding pixels (12) Gray 10 screen definition: All areas of the screen are colored with the following settings: Red = 10/255 Green = 10/255 Blue = 10/255 (13) POM definition: Rectangular border of off-state mirrors surrounding the active area (14) Dark pixel definition: A single pixel or mirror that is stuck in the OFF position and is visibly darker than the surrounding pixels (15) Adjacent pixel definition: Two or more stuck pixels sharing a common border or common point, also referred to as a cluster (16) Unstable pixel definition: A single pixel or mirror that does not operate in sequence with parameters loaded into memory. The unstable pixel appears to be flickering asynchronously with the image DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

18 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

(0,0) (1279, 719) Tilted Axis of Pixel Rotation Off-State Landed Edge On-State Landed Edge Off-State Light Path (0,719) (1279,0) Figure 6-18. Landed Pixel Orientation and Tilt www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 19 Product Folder Links: DLP3010LC

6.12 Window Characteristics

PARAMETER(3) MIN NOM MAX UNIT Window material designation Corning Eagle XG Window refractive index at wavelength 546.1 nm 1.5119 Window aperture(1) See (1) Illumination overfill(2) See (2) Window transmittance, single-pass through both surfaces and glass Minimum within the wavelength range 420 to 680 nm. Applies to all angles 0° to 30° AOI. 97% Window Transmittance, single-pass through both surfaces and glass Average over the wavelength range 420 to 680 nm. Applies to all angles 30° to 45° AOI. 97% (1) See the package mechanical characteristics for details regarding the size and location of the window aperture. (2) The active area of the 7212-313BK device is surrounded by an aperture on the inside of the DMD window surface that masks structures of the DMD device assembly from normal view. The aperture is sized to anticipate several optical conditions. Overfill light illuminating the area outside the active array can scatter and create adverse effects to the performance of an end application using the DMD. The illumination optical system should be designed to limit light flux incident outside the active array to less than 10% of the average flux level in the active area. Depending on the particular system's optical architecture and assembly tolerances, the amount of overfill light on the outside of the active array may cause system performance degradation. (3) See Section 7.5 for more information. SPACER

6.13 Chipset Component Usage Specification

The 7212-313BK is a component of one or more TI DLP ® chipsets. Reliable function and operation of the 7212-313BK requires that it be used in conjunction with the other components of the applicable DLP chipset, including those components that contain or implement TI DMD control technology. TI DMD control technology is the TI technology and devices for operating or controlling a DLP DMD. Note TI assumes no responsibility for image quality artifacts or DMD failures caused by optical system operating conditions exceeding limits described previously.

6.14 Software Requirements

The 7212-313BK DMD has mandatory software requirements. Refer to Software Requirements for TI DLP®Pico™ TRP Digital Micromirror Devices application report for additional information. Failure to use the specified software will result in failure at power up. DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

20 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

7 Detailed Description

7.1 Overview

The 7212-313BK DMD is a 0.3 inch diagonal spatial light modulator of aluminum micromirrors. Pixel array size is 1280 columns by 720 rows in a square grid pixel arrangement. The electrical interface is Sub Low Voltage Differential Signaling (SubLVDS) data. This DMD is part of the chipset that includes the 7212-313BK DMD, DLPC3478 display and light controller and DLPA200x/DLPA300x PMIC/LED driver. To ensure reliable operation, this DMD must always be used with DLPC3478 display and light controller and DLPA200x/DLPA300x PMIC/LED driver. www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: DLP3010LC

7.2 Functional Block Diagram

(0,0) Voltages Misc Voltage Generators High-Speed Interface Control SRAM (719,1279) Row Low-Speed Interface ControlColumn Write ControlColumn Read VBIAS VRESET VSS VOFFSET LS_RDATA DMD_DEN_ARSTZ VDD LS_WDATA VBIAS VRESET VSS VOFFSET VDDI D_P(0:3) DCLK_P DCLK_N VDD D_N(0:3) A. Details omitted for clarity B. Orientation is not representative of optical system C. Scale is not representative of layout DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

22 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

7.3 Feature Description

7.3.1 Power Interface

The power management IC, DLPA200x/DLPA300x, contains 3 regulated DC supplies for the DMD reset circuitry: VBIAS, VRESET and VOFFSET, as well as the 2 regulated DC supplies for the DLPC3478 controller.

7.3.2 Low-Speed Interface

The Low Speed Interface handles instructions that configure the DMD and control reset operation. LS_CLK is the low–speed clock, and LS_WDATA is the low speed data input.

7.3.3 High-Speed Interface

The purpose of the high-speed interface is to transfer pixel data rapidly and efficiently, making use of high speed DDR transfer and compression techniques to save power and time. The high-speed interface is composed of differential SubLVDS receivers for inputs, with a dedicated clock.

7.3.4 Timing

The data sheet provides timing test results at the device pin. For output timing analysis, the tester pin electronics and its transmission line effects must be considered. Test Load Circuit for Output Propagation Measurement shows an equivalent test load circuit for the output under test. Timing reference loads are not intended as a precise representation of any particular system environment or depiction of the actual load presented by a production test. TI recommends that system designers use IBIS or other simulation tools to correlate the timing reference load to a system environment. The load capacitance value stated is intended for characterization and measurement of AC timing signals only. This load capacitance value does not indicate the maximum load the device is capable of driving.

7.4 Device Functional Modes

DMD functional modes are controlled by the DLPC3478 controller. See the DLPC3478 controller data sheet or contact a TI applications engineer.

7.5 Optical Interface and System Image Quality Considerations

TI assumes no responsibility for image quality artifacts or DMD failures caused by optical system operating conditions exceeding limits described previously.

7.5.1 Optical Interface and System Image Quality

TI assumes no responsibility for end-equipment optical performance. Achieving the desired end-equipment optical performance involves making trade-offs between numerous component and system design parameters. Optimizing system optical performance and image quality strongly relate to optical system design parameter trades. Although it is not possible to anticipate every conceivable application, projector image quality and optical performance is contingent on compliance to the optical system operating conditions described in the following sections.

7.5.1.1 Numerical Aperture and Stray Light Control

The angle defined by the numerical aperture of the illumination and projection optics at the DMD optical area is typically the same. Ensure this angle does not exceed the nominal device micromirror tilt angle unless appropriate apertures are added in the illumination or projection pupils to block out flat-state and stray light from the projection lens. The micromirror tilt angle defines DMD capability to separate the "ON" optical path from any other light path, including undesirable flat–state specular reflections from the DMD window, DMD border structures, or other system surfaces near the DMD such as prism or lens surfaces. If the numerical aperture exceeds the micromirror tilt angle, or if the projection numerical aperture angle is more than two degrees larger than the illumination numerical aperture angle (and vice versa), contrast degradation and objectionable artifacts in the display border and/or active area may occur. www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 23 Product Folder Links: DLP3010LC

7.5.1.2 Pupil Match

The optical and image quality specifications assume that the exit pupil of the illumination optics is nominally centered within 2° of the entrance pupil of the projection optics. Misalignment of pupils can create objectionable artifacts in the display border and/or active area. These artifacts may require additional system apertures to control, especially if the numerical aperture of the system exceeds the pixel tilt angle.

7.5.1.3 Illumination Overfill

The active area of the device is surrounded by an aperture on the inside DMD window surface that masks structures of the DMD chip assembly from normal view, and is sized to anticipate several optical operating conditions. Overfill light illuminating the window aperture can create artifacts from the edge of the window aperture opening and other surface anomalies that may be visible on the screen. Be sure to design an illumination optical system that limits light flux incident anywhere on the window aperture from exceeding approximately 10% of the average flux level in the active area. Depending on the particular optical architecture, overfill light may require further reduction below the suggested 10% level in order to be acceptable.

7.6 Micromirror Array Temperature Calculation

(4 surfaces) TP3 TP2 TP2 TP3 TP1 TP1 Illumination Direction Off-state Light Figure 7-1. DMD Thermal Test Points Micromirror array temperature cannot be measured directly, therefore it must be computed analytically from measurement points on the outside of the package, the package thermal resistance, the electrical power, and the illumination heat load. The relationship between array temperature and the reference ceramic temperature (thermal test TP1 in Figure 7-1) is provided by the following equations: TARRAY = TCERAMIC + (QARRAY × RARRAY-TO-CERAMIC) QARRAY = QELECTRICAL + QILLUMINATION where DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

24 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

  • TARRAY = Computed array temperature (°C)
  • TCERAMIC = Measured ceramic temperature (°C) (TP1 location)
  • RARRAY-TO-CERAMIC = Thermal resistance of package specified in Section 6.5 from array to ceramic TP1 (°C/Watt)
  • QARRAY = Total DMD power on the array (W) (electrical + absorbed)
  • QELECTRICAL = Nominal electrical power (W)
  • QINCIDENT = Incident illumination optical power (W)
  • QILLUMINATION = (DMD average thermal absorptivity × QINCIDENT) (W)
  • DMD average thermal absorptivity = 0.4 The electrical power dissipation of the DMD is variable and depends on the voltages, data rates and operating frequencies. A nominal electrical power dissipation to use when calculating array temperature is 0.10 Watts. The absorbed power from the illumination source is variable and depends on the operating state of the micromirrors and the intensity of the light source. The equations shown above are valid for a single chip or multichip DMD system. It assumes an illumination distribution of 83.7% on the active array, and 16.3% on the array border. The sample calculation for a typical projection application is as follows: QINCIDENT = 2.2 W (measured) TCERAMIC = 55.0°C (measured) QELECTRICAL = 0.10 W QARRAY = 0.10 W + (0.40 × 2.2 W) = 0.98 W

7.7 Micromirror Power Density Calculation

The calculation of the optical power density of the illumination on the DMD in the different wavelength bands uses the total measured optical power on the DMD, percent illumination overfill, area of the active array, and ratio of the spectrum in the wavelength band of interest to the total spectral optical power.

  • ILLUV = [OPUV-RATIO × QINCIDENT] × 1000 ÷ AILL (mW/cm2)
  • ILLVIS = [OPVIS-RATIO × QINCIDENT] ÷ AILL (W/cm2)
  • ILLIR = [OPIR-RATIO × QINCIDENT] × 1000 ÷ AILL (mW/cm2)
  • ILLBLU = [OPBLU-RATIO × QINCIDENT] ÷ AILL (W/cm2)
  • ILLBLU1 = [OPBLU1-RATIO × QINCIDENT] ÷ AILL (W/cm2)
  • AILL = AARRAY ÷ (1 - OVILL) (cm2) where:
  • ILLUV = UV illumination power density on the DMD (mW/cm2)
  • ILLVIS = VIS illumination power density on the DMD (W/cm2)
  • ILLIR = IR illumination power density on the DMD (mW/cm2)
  • ILLBLU = BLU illumination power density on the DMD (W/cm2)
  • ILLBLU1 = BLU1 illumination power density on the DMD (W/cm2) www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 25 Product Folder Links: DLP3010LC
  • AILL = illumination area on the DMD (cm2)
  • QINCIDENT = total incident optical power on DMD (W) (measured)
  • AARRAY = area of the array (cm 2) (data sheet)
  • OVILL = percent of total illumination on the DMD outside the array (%) (optical model)
  • OPUV-RATIO = ratio of the optical power for wavelengths <410 nm to the total optical power in the illumination spectrum (spectral measurement)
  • OPVIS-RATIO = ratio of the optical power for wavelengths ≥410 and ≤800 nm to the total optical power in the illumination spectrum (spectral measurement)
  • OPIR-RATIO = ratio of the optical power for wavelengths >800 nm to the total optical power in the illumination spectrum (spectral measurement)
  • OPBLU-RATIO = ratio of the optical power for wavelengths ≥410 and ≤475 nm to the total optical power in the illumination spectrum (spectral measurement)
  • OPBLU1-RATIO = ratio of the optical power for wavelengths ≥410 and ≤445 nm to the total optical power in the illumination spectrum (spectral measurement) The illumination area varies and depends on the illumination overfill. The total illumination area on the DMD is the array area and overfill area around the array. The optical model is used to determine the percent of the total illumination on the DMD that is outside the array (OV ILL) and the percent of the total illumination that is on the active array. From these values the illumination area (A ILL) is calculated. The illumination is assumed to be uniform across the entire array. From the measured illumination spectrum, the ratio of the optical power in the wavelength bands of interest to the total optical power is calculated. Sample calculation: QINCIDENT = 2.20 W (measured) AARRAY = (0.6912× 0.3888) = 0.2687 cm2 (data sheet) OVILL = 16.3% (optical model) OPUV-RATIO = 0.00021 (spectral measurement) OPVIS-RATIO = 0.99977 (spectral measurement) OPIR-RATIO = 0.00002 (spectral measurement) OPBLU-RATIO = 0.28100 (spectral measurement) OPBLU1-RATIO = 0.03200 (spectral measurement) AILL = 0.2687 ÷ (1 - 0.163) = 0.3211 cm2 ILLUV = [0.00021 × 2.20W] × 1000 ÷ 0.3211 cm2 = 1.439 mW/cm2 ILLVIS = [0.99977 × 2.20W] ÷ 0.3211 cm2 = 6.85 W/cm2 ILLIR = [0.00002 × 2.20W] × 1000 ÷ 0.3211 cm2 = 0.137 mW/cm2 ILLBLU = [0.28100 × 2.20W] ÷ 0.3211 cm2 = 1.93 W/cm2 ILLBLU1 = [0.03200 × 2.20W] ÷ 0.3211 cm2 = 0.219 W/cm2 DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

26 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

7.8 Micromirror Landed-On/Landed-Off Duty Cycle

7.8.1 Definition of Micromirror Landed-On and Landed-Off Duty Cycle

The micromirror landed-on/landed-off duty cycle (landed duty cycle) denotes the amount of time (as a percentage) that an individual micromirror is landed in the ON state versus the amount of time the same micromirror is landed in the OFF state. As an example, a landed duty cycle of 75/25 indicates that the referenced pixel is in the ON state 75% of the time (and in the OFF state 25% of the time), whereas 25/75 indicates that the pixel is in the OFF state 75% of the time. Likewise, 50/50 indicates that the pixel is ON 50% of the time and OFF 50% of the time. When assessing landed duty cycle, the time spent switching from the current state to the opposite state is considered negligible and is thus ignored. Because a micromirror can only be landed in one state or the other (ON or OFF), the two numbers (percentages) nominally add to 100.In practice, image processing algorithms in the DLP chipset can result a total of less that 100.

7.8.2 Landed Duty Cycle and Useful Life of the DMD

Knowing the long-term average landed duty cycle (of the end product or application) is important because subjecting all (or a portion) of the DMD’s micromirror array (also called the active array) to an asymmetric landed duty cycle for a prolonged period of time can reduce the DMD’s usable life. It is the symmetry or asymmetry of the landed duty cycle that is relevant. The symmetry of the landed duty cycle is determined by how close the two numbers (percentages) are to being equal. For example, a landed duty cycle of 50/50 is perfectly symmetrical whereas a landed duty cycle of 100/0 or 0/100 is perfectly asymmetrical.

7.8.3 Landed Duty Cycle and Operational DMD Temperature

Operational DMD temperature and landed duty cycle interact to affect the usable life of the DMD. This interaction can be used to reduce the impact that an asymmetrical landed duty cycle has on the useable life of the DMD. Figure 6-1 describes this relationship. The importance of this curve is that:

  • All points along this curve represent the same usable life.
  • All points above this curve represent lower usable life (and the further away from the curve, the lower the usable life).
  • All points below this curve represent higher usable life (and the further away from the curve, the higher the usable life). In practice, this curve specifies the maximum operating DMD temperature that the DMD should be operated at for a give long-term average landed duty cycle.

7.8.4 Estimating the Long-Term Average Landed Duty Cycle of a Product or Application

During a given period of time, the landed duty cycle of a given pixel depends on the image content being displayed by that pixel. In the simplest case for example, when the system displays pure-white on a given pixel for a given time period, that pixel operates very close to a 100/0 landed duty cycle during that time period. Likewise, when the system displays pure-black, the pixel operates very close to a 0/100 landed duty cycle. Between the two extremes (ignoring for the moment color and any image processing that may be applied to an incoming image), the landed duty cycle tracks one-to-one with the gray scale value, as shown in Table 7-1. Table 7-1. Grayscale Value and Landed Duty Cycle Grayscale Value Nominal Landed Duty Cycle 0% 0/100 www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 27 Product Folder Links: DLP3010LC

Table 7-1. Grayscale Value and Landed Duty Cycle (continued) Grayscale Value Nominal Landed Duty Cycle 10% 10/90 20% 20/80 30% 30/70 40% 40/60 50% 50/50 60% 60/40 70% 70/30 80% 80/20 90% 90/10 100% 100/0 To account for color rendition (and continuing to ignore image processing for this example) requires knowing both the color intensity (from 0% to 100%) for each constituent primary color (red, green, and/or blue) for the given pixel as well as the color cycle time for each primary color, where color cycle time describes the total percentage of the frame time that a given primary must be displayed in order to achieve the desired white point. During a given period of time, the nominal landed duty cycle of a given pixel can be calculated as shown in Equation 1: Landed Duty Cycle = (Red_Cycle_% × Red_Scale_Value) + (Green_Cycle_% × Green_Scale_Value) + (Blue_Cycle_% × Blue_Scale_Value) (1) where

  • Red_Cycle_% represents the percentage of the frame time that red displays to achieve the desired white point
  • Green_Cycle_% represents the percentage of the frame time that green displays to achieve the desired white point
  • Blue_Cycle_% represents the percentage of the frame time that blue displays to achieve the desired white point For example, assume that the ratio of red, green and blue color cycle times are as listed in Table 7-2 (in order to achieve the desired white point) then the resulting nominal landed duty cycle for various combinations of red, green, blue color intensities are as shown in Table 7-3. Table 7-2. Example Landed Duty Cycle for Full-Color Pixels Red Cycle Percentage Green Cycle Percentage Blue Cycle Percentage 50% 20% 30% Table 7-3. Color Intensity Combinations Red Scale Value Green Scale Value Blue Scale Value Nominal Landed Duty Cycle 0% 0% 0% 0/100 100% 0% 0% 50/50 0% 100% 0% 20/80 0% 0% 100% 30/70 DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

28 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

Table 7-3. Color Intensity Combinations (continued) Red Scale Value Green Scale Value Blue Scale Value Nominal Landed Duty Cycle 12% 0% 0% 6/94 0% 35% 0% 7/93 0% 0% 60% 18/82 100% 100% 0% 70/30 0% 100% 100% 50/50 100% 0% 100% 80/20 12% 35% 0% 13/87 0% 35% 60% 25/75 12% 0% 60% 24/76 100% 100% 100% 100/0 The last factor to consider when estimating the landed duty cycle is any applied image processing. In the DLPC34xx controller family, the two functions which influence the actual landed duty cycle are Gamma and IntelliBright™, and bitplane sequencing rules. Gamma is a power function of the form Output_Level = A × Input_Level Gamma, where A is a scaling factor that is typically set to 1. In the DLPC34xx controller family, gamma is applied to the incoming image data on a pixel-by-pixel basis. A typical gamma factor is 2.2, which transforms the incoming data as shown in Figure 7-2. Figure 7-2. Example of Gamma = 2.2 As shown in Figure 7-2, when the gray scale value of a given input pixel is 40% (before gamma is applied), then gray scale value is 13% after gamma is applied. Because gamma has a direct impact on the displayed gray scale level of a pixel, it also has a direct impact on the landed duty cycle of a pixel. The IntelliBright algorithms content adaptive illumination control (CAIC) and local area brightness boost (LABB) also apply transform functions on the gray scale level of each pixel. But while amount of gamma applied to every pixel (of every frame) is constant (the exponent, gamma, is constant), CAIC and LABB are both adaptive functions that can apply a different amounts of either boost or compression to every pixel of every frame. Be sure to account for any image processing which occurs before the controller. 7.8.5 The IntelliBright algorithm content adaptive illumination control (CAIC) and local area brightness boost (LABB) also apply transform functions on the gray scale level of each pixel. But while the amount of gamma correction applied to every pixel (of every frame) is constant (the exponent, gamma, is constant), CAIC and LABB are both adaptive functions that can apply a different amounts of either boost or compression to every pixel of every frame. The CAIC and LABB algorithms receive no information regarding any previous gain or boost processing. In cases where the application performs any processing of the input data before the image reaches the DLPC3478 controller, unexpected behavior such as saturation may occur. www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 29 Product Folder Links: DLP3010LC

8 Application and Implementation

Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes, as well as validating and testing their design implementation to confirm system functionality.

8.1 Application Information

The DMDs are spatial light modulators which reflect incoming light from an illumination source to one of two directions, with the primary direction being into a projection or collection optic. Each application depends primarily on the optical architecture of the system and the format of the data coming into the DLPC3478 controller. The new high-tilt pixel in the side-illuminated DMD increases brightness performance and enables a smaller system electronics footprint for thickness constrained applications. Applications include

  • Integrated display and 3D depth capture – Smart phone, tablets, laptop, camera – Battery-powered mobile accessory
  • 3D depth capture: 3D camera, 3D reconstruction, AR/VR, dental scanner
  • 3D machine vision: robotics, metrology, in-line inspection (AOI)
  • 3D biometrics: facial and finger print recognition
  • Light exposure: 3D printers, programmable spatial and temporal light exposure DMD power-up and power-down sequencing is strictly controlled by the DLPA200x/DLPA300x. Refer to Section 9 for power-up and power-down specifications. 7212-313BK DMD reliability is specified when used with DLPC3478 controller and DLPA200x/DLPA300x PMIC/LED driver only.

8.2 Typical Application

DLP3010LC DMD with DLPC3478 controller enables high accuracy and very small form factor 3D depth scanner products. Figure 8-1 shows a typical 3D depth scanner system block diagram using external pattern streaming mode. DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

30 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

VBIAS, VOFFSET, VRESET SYSPWR Sub-LVDS DATA PROJ_ON HOST_IRQ I2C Flash Parallel Interface (28) VLED CTRL RLIM 1.8 V external 1.8 V PROJ_ON VCC_18 VCC_INTF VCC_FLSH VDD SPI (4) SPI (4) INTZ Thermistor VDDLP12 SPI0 SPI1 RESETZ PARKZ GPIO_8 GPIO_10 CMP_OUT 1.8 V 1.1 V Video Front End System Controller HDMI Keypad DC Supplies VSPI1.8 V

1.1 Reg

1.1 V LED_SEL (2) RC_ CHARGE 1.8 V TSTPT_4 GPIO_7 TRIG_OUT_1 TRIG_OUT_2 Figure 8-1. Typical Application

8.2.1 Design Requirements

A high-accuracy 3D depth scanner product can be created by using a DLP chipset comprised of DLP3010 DMD, DLPC3478 controller and DLPA200x or DLPA300x PMIC/LED driver. The DLPC3478 simplifies the pattern generation, the DLPA200x or DLPA300x provides the needed analog functions and the DMD displays the required patterns for accurate 3D depth scanning. In addition to the three DLP devices in the chipset, other IC components may be needed. At a minimum, this design requires a flash device to store the software and firmware to control the DLPC3478 . Red, green, and blue LEDs typically supply the illumination light that is applied to the DMD. These LEDs are often contained in three separate packages, but sometimes more than one color of LED die may be in the same package to reduce the overall size of the pico-projector. In addition to LEDs, other light sources like laser diodes, vertical-cavity surface-emitting laser (VCSEL) are also supported. The parallel interface connects the DLPC3478 controller to the host processing for receiving patterns or video data. Connect an I2C interface to the host processor to send commands to the DLPC3478 controller. The battery (SYSPWR) and a regulated 1.8-V supply are the only power supplies needed external to the projector in case of DLPA200x. The DLPA300x supplies 1.8 V without external regulator. A single signal (PROJ_ON) controls the entire DLP system power. When PROJ_ON is high, the DLP system turns on and when PROJ_ON is low, the DLPC3478 turns off. When the DLPC3478 is off, the DLP system draws only a few microamperes of current on SYSPWR. When PROJ_ON is low, the 1.8-V power supply can remain at 1.8 V for use by other sub systems. When PROJ_ON is low, the DLPA200x or DLPA300x draws no current on the 1.8-V supply.

8.2.2 Detailed Design Procedure

For more information on connecting the DLPC3478, the DLPA200x/DLPA300x, and the DMD, see the reference design schematic. Based on the reference schematic a small circuit board can be created. An example small board layout is included in the reference design data base. Layout guidelines should be followed to achieve a reliable projector. www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 31 Product Folder Links: DLP3010LC

The optical engine that has the LED packages and the DMD mounted to it is typically supplied by an optical OEM who specializes in designing optics for DLP projectors.

8.2.3 Application Curve

This device drives current time-sequentially though the LEDs. As the LED currents through the red, green, and blue LEDs increases, the brightness of the projector increases. This increase is somewhat non-linear, and the curve for typical white screen lumens changes with LED currents as shown in Figure 8-2. For the LED currents shown, assumed that the same current amplitude is applied to the red, green, and blue. SPACE Current (mA) Luminance 0 100 200 300 400 500 600 700 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 D001 ILED(red) = ILED(green) = ILED(blue) Figure 8-2. Luminance vs Current DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

32 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

9 Power Supply Recommendations

The following power supplies are all required to operate the DMD:

  • VSS
  • VBIAS
  • VDD
  • VDDI
  • VOFFSET
  • VRESET DMD power-up and power-down sequencing is strictly controlled by the DLPAxxxx device. CAUTION For reliable operation of the DMD, the following power supply sequencing requirements must be followed. Failure to adhere to any of the prescribed power-up and power-down requirements may affect device reliability. See the DMD power supply sequencing requirements in Figure 9-1. VBIAS, VDD, VDDI, VOFFSET, and V RESET power supplies must be coordinated during power-up and power-down operations. Failure to meet any of the below requirements will result in a significant reduction in the DMD reliability and lifetime. Common ground VSS must also be connected.

9.1 DMD Power Supply Power-Up Procedure

  • During power-up, VDD and VDDI must always start and settle before VOFFSET, VBIAS, and VRESET voltages are applied to the DMD.
  • During power-up, it is a strict requirement that the voltage difference between VBIAS and VOFFSET must be within the specified limit shown in Section 6.4. Refer to Table 9-1 for power-up delay requirements.
  • During power-up, there is no requirement for the relative timing of VRESET with respect to VBIAS and VOFFSET.
  • Power supply slew rates during power-up are flexible, provided that the transient voltage levels follow the requirements specified in Section 6.1, in Section 6.4, and in Section 9.3.
  • During power-up, LPSDR input pins must not be driven high until after VDD /VDDI have settled at operating voltages listed in Section 6.4.

9.2 DMD Power Supply Power-Down Procedure

  • Power-down sequence is the reverse order of the previous power-up sequence. During power-down, VDD and VDDI must be supplied until after VBIAS, VRESET, and VOFFSET are discharged to within 4 V of ground.
  • During power-down, it is a strict requirement that the voltage difference between VBIAS and VOFFSET must be within the specified limit shown in Section 6.4.
  • During power-down, there is no requirement for the relative timing of VRESET with respect to VBIAS and VOFFSET.
  • Power supply slew rates during power-down are flexible, provided that the transient voltage levels follow the requirements specified in Section 6.1, inSection 6.4, and in Section 9.3.
  • During power-down, LPSDR input pins must be less than VDD /VDDI specified in Section 6.4. www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 33 Product Folder Links: DLP3010LC

9.3 Power Supply Sequencing Requirements

VBIAS < 4 V VOFFSET < 4 V VRESET < 0.5 V VDD VRESET > - 4 V VSSDMD_DEN_ARSTZ Note 4 VSS VSS VSS VSS VSS VSS VDD VDD / VDDI VSS VSS VSS VSS VSS LS_WDATA DCLK_P, DCLK_N VSS VID VSS VDD / VDDI VBIAS VOFFSET VRESET VDD VDD VID Note 2Note 3 ûV < Specification Limit Note 2 LS_CLK D_P(0:3), D_N(0:3) < 6 V VDD < VBIAS < 6 V INITIALIZATION DLP Display Controller and PMIC control start of DMD operation DLP Display Controller and PMIC disable VBIAS, VOFFSET and VRESET Note 1 ûV < Specification Limit ûV < Specification Limit VDD < VOFFSET A. Refer to Table 9-1 and Figure 9-2 for critical power-up sequence delay requirements. B. To prevent excess current, the supply voltage delta |VBIAS – VOFFSET| must be less than specified in Section 6.4. OEMs may find that the most reliable way to ensure this is to power VOFFSET prior to VBIAS during power-up and to remove VBIAS prior to VOFFSET during power-down. Refer to Table 9-1 and Figure 9-2 for power-up delay requirements. C. To prevent excess current, the supply voltage delta |VBIAS – VRESET| must be less than specified limit shown in Section 6.4. D. When system power is interrupted, the ASIC driver initiates hardware power-down that disables VBIAS, VRESET and VOFFSET after the Micromirror Park Sequence. Software power-down disables VBIAS, VRESET, and VOFFSET after the Micromirror Park Sequence through software control. E. Drawing is not to scale and details are omitted for clarity. Figure 9-1. Power Supply Sequencing Requirements (Power Up and Power Down) Table 9-1. Power-Up Sequence Delay Requirement PARAMETER MIN MAX UNIT tDELAY Delay requirement from VOFFSET power up to VBIAS power up 2 ms VOFFSET Supply voltage level during power–up sequence delay (see Figure 9-2) 6 V DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

34 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

Table 9-1. Power-Up Sequence Delay Requirement (continued) PARAMETER MIN MAX UNIT VBIAS Supply voltage level during power–up sequence delay (see Figure 9-2) 6 V Time tDELAY VBIAS Voltage (V) VOFFSET Voltage (V) VOFFSET 9''”92))6(7”6 V VSS VSS 9''”9%,$6”6 V VBIAS A. Refer to Table 9-1 for VOFFSET and VBIAS supply voltage levels during power-up sequence delay. Figure 9-2. Power-Up Sequence Delay Requirement www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 35 Product Folder Links: DLP3010LC

10 Layout

10.1 Layout Guidelines

There are no specific layout guidelines for the DMD as typically DMD is connected using a board to board connector to a flex cable. Flex cable provides the interface of data and control signals between the DLPC3478 controller and the 7212-313BK DMD. For detailed layout guidelines refer to the layout design files. Some layout guideline for the flex cable interface with DMD are:

  • Match lengths for the LS_WDATA and LS_CLK signals.
  • Minimize vias, layer changes, and turns for the HS bus signals. Refer Figure 10-1.
  • Minimum of two 100-nF decoupling capacitor close to VBIAS. Capacitor C6 and C7 in Figure 10-1.
  • Minimum of two 100-nF decoupling capacitor close to VRST. Capacitor C9 and C8 in Figure 10-1.
  • Minimum of two 220-nF decoupling capacitor close to VOFS. Capacitor C5 and C4 in Figure 10-1.
  • Minimum of four 100-nF decoupling capacitor close to VDDI and VDD. Capacitor C1, C2, C3 and C10 in Figure 10-1.

10.2 Layout Example

Figure 10-1. Power Supply Connections DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

36 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

11 Device and Documentation Support

11.1 Device Support

11.1.1 Third-Party Products Disclaimer

TI'S PUBLICATION OF INFORMATION REGARDING THIRD-PARTY PRODUCTS OR SERVICES DOES NOT CONSTITUTE AN ENDORSEMENT REGARDING THE SUITABILITY OF SUCH PRODUCTS OR SERVICES OR A WARRANTY, REPRESENTATION OR ENDORSEMENT OF SUCH PRODUCTS OR SERVICES, EITHER ALONE OR IN COMBINATION WITH ANY TI PRODUCT OR SERVICE.

11.1.2 Device Nomenclature

Figure 11-1. Part Number Description

11.1.3 Device Markings

The device marking includes the legible character string GHJJJJK DLP3010LCFQK. GHJJJJK is the lot trace code. DLP3010LCFQK is the orderable device number. Lot Trace Code GHJJJJK DLP3010LCFQK Part Marking Figure 11-2. DMD Marking

11.2 Documentation Support

11.3 Receiving Notification of Documentation Updates

To receive notification of documentation updates, navigate to the device product folder on ti.com. Click on Subscribe to updates to register and receive a weekly digest of any product information that has changed. For change details, review the revision history included in any revised document.

11.4 Related Links

Table 11-1 lists quick access links. Categories include technical documents, support and community resources, tools and software, and quick access to sample or buy. Table 11-1. Related Links PARTS PRODUCT FOLDER SAMPLE & BUY TECHNICAL DOCUMENTS TOOLS & SOFTWARE SUPPORT & COMMUNITY DLPC3478 Click here Click here Click here Click here Click here DLPA2000 Click here Click here Click here Click here Click here DLPA2005 Click here Click here Click here Click here Click here DLPA3000 Click here Click here Click here Click here Click here www.ti.com DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 37 Product Folder Links: DLP3010LC

Table 11-1. Related Links (continued) PARTS PRODUCT FOLDER SAMPLE & BUY TECHNICAL DOCUMENTS TOOLS & SOFTWARE SUPPORT & COMMUNITY DLPA3005 Click here Click here Click here Click here Click here

11.5 Support Resources

TI E2E™ support forums are an engineer's go-to source for fast, verified answers and design help — straight from the experts. Search existing answers or ask your own question to get the quick design help you need. Linked content is provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use.

11.6 Trademarks

Pico™, IntelliBright™, and TI E2E™ are trademarks of Texas Instruments. DLP® is a registered trademark of Texas Instruments. All trademarks are the property of their respective owners.

11.7 Electrostatic Discharge Caution

This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.

11.8 Glossary

TI Glossary This glossary lists and explains terms, acronyms, and definitions.

12 Mechanical, Packaging, and Orderable Information

The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. DLP3010LC DLPS179C – APRIL 2020 – REVISED JULY 2023 www.ti.com

38 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated

Product Folder Links: DLP3010LC

www.ti.com 2-Jun-2025 PACKAGING INFORMATION Orderable part number Status (1) Material type (2) Package | Pins Package qty | Carrier RoHS (3) Lead finish/ Ball material (4) MSL rating/ Peak reflow (5) Op temp (°C) Part marking (6) DLP3010LCFQK Active Production CLGA (FQK) | 57 120 | JEDEC TRAY (5+1) Yes NI/AU N/A for Pkg Type 0 to 70 DLP3010LCFQK.B Active Production CLGA (FQK) | 57 120 | JEDEC TRAY (5+1) Yes NI/AU N/A for Pkg Type 0 to 70 (1) Status: For more details on status, see our product life cycle. (2) Material type: When designated, preproduction parts are prototypes/experimental devices, and are not yet approved or released for full production. Testing and final process, including without limitation quality assurance, reliability performance testing, and/or process qualification, may not yet be complete, and this item is subject to further changes or possible discontinuation. If available for ordering, purchases will be subject to an additional waiver at checkout, and are intended for early internal evaluation purposes only. These items are sold without warranties of any kind. (3) RoHS values: Yes, No, RoHS Exempt. See the TI RoHS Statement for additional information and value definition. (4) Lead finish/Ball material: Parts may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead finish/Ball material values may wrap to two lines if the finish value exceeds the maximum column width. (5) MSL rating/Peak reflow: The moisture sensitivity level ratings and peak solder (reflow) temperatures. In the event that a part has multiple moisture sensitivity ratings, only the lowest level per JEDEC standards is shown. Refer to the shipping label for the actual reflow temperature that will be used to mount the part to the printed circuit board. (6) Part marking: There may be an additional marking, which relates to the logo, the lot trace code information, or the environmental category of the part. Multiple part markings will be inside parentheses. Only one part marking contained in parentheses and separated by a "~" will appear on a part. If a line is indented then it is a continuation of the previous line and the two combined represent the entire part marking for that device. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1

PACKAGE MATERIALS INFORMATION www.ti.com 23-May-2025 TRAY L - Outer tray length without tabs KO - Outer tray height W - Outer tray width P1 - Tray unit pocket pitch CW - Measurement for tray edge (Y direction) to corner pocket center CL - Measurement for tray edge (X direction) to corner pocket center Text Chamfer on Tray corner indicates Pin 1 orientation of packed units. *All dimensions are nominal Device Package Name Package Type Pins SPQ Unit array matrix Max temperature (°C) L (mm) W (mm) (µm) (mm) CL (mm) CW (mm) DLP3010LCFQK FQK CLGA 57 120 10 x 12 150 315 135.9 12190 23 31 16.2 DLP3010LCFQK.B FQK CLGA 57 120 10 x 12 150 315 135.9 12190 23 31 16.2 Pack Materials-Page 1

D C B A DWG NO. SH8 7 6 5 4 3 1 D C B A INV11-2006a 2512014 1 TITLE SIZE DWG NO REV SCALE SHEET OF DATE ENGINEER QA/CE CM APPROVED DRAWN INSTRUMENTS Dallas Texas APPLICATION NEXT ASSY USED ON THIRD ANGLE PROJECTION TEXASUNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS TOLERANCES: ANGLES 1 2 PLACE DECIMALS 0.25 1 PLACE DECIMALS 0.50 DIMENSIONAL LIMITS APPLY BEFORE PROCESSES INTERPRET DIMENSIONS IN ACCORDANCE WITH ASME Y14.5M-1994 REMOVE ALL BURRS AND SHARP EDGES PARENTHETICAL INFORMATION FOR REFERENCE ONLY ICD, MECHANICAL, DMD, .3 720p SERIES 245 (FQK PACKAGE) 2512014 1 3 CD 6/6/2013 20:1 P. KONRAD S. SUSI R. LONG 6/7/2013 6/6/2013 6/6/2013 6/6/2013 0314DA B. HASKETT NOTES UNLESS OTHERWISE SPECIFIED: REVISIONSCOPYRIGHT 2013 TEXAS INSTRUMENTS UN-PUBLISHED, ALL RIGHTS RESERVED. C B. HASKETT S. CROFF 6/10/2013 A A H H REV DESCRIPTION DATE BY A ECO 2133835: INITIAL RELEASE 6/6/2013 BMH B ECO 2134093: CORRECT WINDOW THK TOL, ZONE B6 6/17/2013 BMH C ECO 2186947: ADD APERTURE SLOTS PICTORIALLY 4/8/2020 PPC 0.78 0.063 D (2.183) A 3 SURFACES INDICATED IN VIEW B (SHEET 2) DIE PARALLELISM TOLERANCE APPLIES TO DMD ACTIVE ARRAY ONLY. ROTATION ANGLE OF DMD ACTIVE ARRAY IS A REFINEMENT OF THE LOCATION TOLERANCE AND HAS A MAXIMUM ALLOWED VALUE OF 0.6 DEGREES. BOUNDARY MIRRORS SURROUNDING THE DMD ACTIVE ARRAY. NOTCH DIMENSIONS ARE DEFINED BY UPPERMOST LAYERS OF CERAMIC, AS SHOWN IN SECTION A-A. ENCAPSULANT TO BE CONTAINED WITHIN DIMENSIONS SHOWN IN VIEW C (SHEET 2). NO ENCAPSULANT IS ALLOWED ON TOP OF THE WINDOW. ENCAPSULANT NOT TO EXCEED THE HEIGHT OF THE WINDOW. DATUM B IS DEFINED BY A DIA. 2.5 PIN, WITH A FLAT ON THE SIDE FACING TOWARD THE CENTER OF THE ACTIVE ARRAY, AS SHOWN IN VIEW B (SHEET 2). WHILE ONLY THE THREE DATUM A TARGET AREAS A1, A2, AND A3 ARE USED FOR MEASUREMENT, ALL 4 CORNERS SHOULD BE CONTACTED, INCLUDING E1, TO SUPPORT MECHANICAL LOADS. (ILLUMINATION DIRECTION) ACTIVE ARRAY 0.038 A 0.02 D (SHEET 3)(SHEET 3) (2.5) (2.5) B (OFF-STATE DIRECTION) 1.176 0.05 7 - 0.1 0.3+ 90° 1° 3.5 - 0.1 0.2+ 0.8 - 0.1 0.2+ 16.4 0.08 18.2 - 0.1 0.3+ 4X (R0.2) 0.4R 0.14X 1.25 2.5 0.0752X (1) 2.25 - 0.1 0.2+ 1.6 0.1

0.4 MIN

TYP. (1.6) 0 MIN TYP. 2X ENCAPSULANT

DATUMS A, B, C, AND E (FROM SHEET 1) VIEW C ENCAPSULANT MAXIMUM X/Y DIMENSIONS (FROM SHEET 1) VIEW D ENCAPSULANT MAXIMUM HEIGHT 2 1345678 D C B A DWG NO. SH8 7 6 5 4 3 1 D C B A INV11-2006a 2512014 2 SIZE DWG NO REV SCALE SHEET OF DATE INSTRUMENTS Dallas Texas TEXAS DRAWN 2512014 2 3 CDB. HASKETT 6/6/2013 1.1762X (0.8)2X 16.42X (1)2X (2)4X 2.5 A1E1 B (1.1)7 (2.5) B 7.2 1.176 16.4 2X 0 MIN 6 1.54X 1.25 C 1.25 C 3.6

(FROM SHEET 1) VIEW H-H BACK SIDE METALLIZATION (FROM SHEET 1) DETAIL F APERTURE LEFT EDGE SCALE 60 : 1 DETAIL G APERTURE RIGHT EDGE SCALE 60 : 1 2 1345678 D C B A DWG NO. SH8 7 6 5 4 3 1 D C B A INV11-2006a 2512014 3 SIZE DWG NO REV SCALE SHEET OF DATE INSTRUMENTS Dallas Texas TEXAS DRAWN 2512014 3 3 CDB. HASKETT 6/6/2013 F G B (6.912) ACTIVE ARRAY (3.888) ACTIVE ARRAY 6.449 0.075 0.971 0.05 5.179 0.05 (6.15) WINDOW 0.193 0.0635 4.319 0.0635 (4.512) APERTURE 8.815 0.05 (11.776) WINDOW (2.5)   (2.5) B

0.2 A B C

0.1 A 1.25 C (ILLUMINATION DIRECTION) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 (0.108)4X 7.139 0.06350.424 0.0635 (7.563) APERTURE 2.961 0.05 1.784 0.075 1.25 C 57X LGA PADS BACK INDEX MARK (0.15) TYP. (42°) TYP. (0.068) TYP. (42°) TYP. (0.068) TYP. (0.075) TYP. (42°) TYP. A B C D E 13.363218 X 0.7424 = 2.874 0.52 0.05( 12X TEST PADS 0.7424 1.4848= 2 X 0.7424 (0.7424)2X (0.7424)

IMPORTANT NOTICE AND DISCLAIMER TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATA SHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, regulatory or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources. TI’s products are provided subject to TI’s Terms of Sale or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products. TI objects to and rejects any additional or different terms you may have proposed. IMPORTANT NOTICE Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2025, Texas Instruments Incorporated