720D ARISTA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 52

Technical content

Datasheet sections

  • 1.1 Scope
  • 1.2 Receiving and Inspecting the Equipment
  • 1.3 Installation Process
  • 1.4 Safety Information
  • 1.5 Obtaining Technical Assistance
  • 1.6 Product and Documentation Updates
  • 1.7 Specifications
  • 2.1 Site Selection
  • 2.2 Tools and Parts Required for Installation
  • 2.3 Electrostatic Discharge (ESD) Precautions
  • 3.1 Two-Post Rack Mount
  • 3.1.1 Attaching Mounting Brackets to the Chassis
  • 3.1.2 Inserting the Switch into the Rack
  • 4.1 Grounding the Switch
  • 4.1.1 Grounding Lug Preparation
  • 4.2 Connecting Power Cables
  • 4.2.1 Connecting AC Power
  • 4.2.2 Connecting DC Power
  • 4.2.3 Connecting DC Power Supply to Power Source
  • 4.3 Connecting Serial and Management Cables
  • 8.1 CCS-720DP-48S
  • 8.2 CCS-720DP-48S-M-S
  • 8.3 CCS-720DP-24S
  • 8.4 CCS-720DP-24S-M-S
  • 8.5 CCS-720DT-48S
  • 8.6 CCS-720DT-24S
  • 8.7 CCS-720DT-24S-M-S

720D Series Ethernet Switch Cognitive Campus Switches CCS-720DP-48S CCS-720DT-48S CCS-720DP-24S CCS-720DT-24S CCS-720DF-48Y CCS-720DF-48Y-DC CCS-720DP-24ZS CCS-720DP-48ZS Arista.com Arista Networks DOC-05297-07

Headquarters Support Sales

5453 Great America Parkway

Santa Clara, CA 95054 USA +1-866-476-0000 +1-408-547-5501 +1-866-497-0000 www.arista.com/en/ support@arista.com sales@arista.com © Copyright 2024 Arista Networks, Inc. All rights reserved. The information contained herein is subject to change without notice. The trademarks, logos, and service marks ("Marks") displayed in this documentation are the property of Arista Networks in the United States and other countries. Use of the Marks is subject to the Arista Networks Terms of Use Policy, available at www.arista.com/en/terms-of-use. Use of marks belonging to other parties is for informational purposes only.

This guide is intended for network or security professionals and technicians who need to install the required Arista 720D Series Ethernet Switch. The following topics are covered in this section:

  • Scope
  • Receiving and Inspecting the Equipment
  • Installation Process
  • Safety Information
  • Obtaining Technical Assistance
  • Product and Documentation Updates
  • Specifications

1.1 Scope

This section lists the devices that are described in this guide: Important: Only qualified personnel should install, service, or replace this equipment. Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.

  • CCS-720DP-48S-2F
  • CCS-720DP-48S-M-S-2F
  • CCS-720DP-24S-2F
  • CCS-720DP-24S-M-S-2F
  • CCS-720DT-48S-2F
  • CCS-720DT-48S-2R
  • CCS-720DT-24S-2F
  • CCS-720DT-24S-M-S-2F
  • CCS-720DT-24S-2R
  • CCS-720DF-48Y-2F
  • CCS-720DF-48Y-M-S-2F
  • CCS-720DF-48Y-DC-2F
  • CCS-720DP-24ZS-2F
  • CCS-720DP-48ZS-2F

1.2 Receiving and Inspecting the Equipment

Upon receiving the device, inspect the shipping boxes and record if there is any external damage. Retain the packing equipment if you suspect any part of the shipment is damaged; the carrier might need it inspected. If the boxes were not damaged during transit, unpack them carefully. Do not discard any accessories that may have been packed in the same box as the switch. Inspect the packing list and confirm that you received all the items listed. Compare the packing list with your purchase order. The Parts List section provides a list of components included with the device.

1.3 Installation Process

This section describes the steps required to install the switch: Important: Class 1 Laser Product: This product has provisions for installing Class 1 laser transceivers that provide optical coupling to the communication network. Once a Class 1 1 laser product is installed, the equipment is a Class 1 Laser Product. The customer is responsible for selecting and installing the Class 1 laser transceiver and for ensuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompany the transceiver before installation. Only Class 1 laser devices certified for use in the country of installation by the cognizant agency are to be utilized in this product. Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteursrécepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 60825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/ récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit. Important: Ultimate disposal of this product should be in accordance with national laws and regulations. Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié. The following steps are to be followed to install the switch: 1. Select the installation site. (Site Selection) 2. Assemble the installation tools listed. (Tools and Parts Required for Installation) 3. Attach the mounting brackets and install the switch in an equipment rack. (Rack Mounting the Switch) 4. Connect the switch to the power source and network devices. (Cabling the Switch) 5. Configure the switch. (Configuring the Switch)

1.4 Safety Information

Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at https://www.arista.com/en/support/product-documentation

1.5 Obtaining Technical Assistance

Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:

  • Email: support@arista.com Include a detailed description of the problem and the “show tech-support” output.
  • Web: https://www.arista.com/en/support A support case may be created through the support portal on our website. You may also download the most recent software and documentation, and view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.
  • Phone: +1 866-476-0000 or +1 408-547-5502.

1.6 Product and Documentation Updates

To receive important news on product updates, please visit our website at https://www.arista.com/en/support/ product-documentation.

1.7 Specifications

This section lists the specifications of the Arista Ethernet Switches described in this guide.

Table 1: Ethernet Switch Specifications (Dimensions and Weights) Device Size (W x H x D) Weight CCS-720DP-48S-2F 440 x 43.5 x 430 mm (17.32 x 1.71 x 16.92 inches) 6.73 kg (14.83 lbs) CCS-720DP-24S-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 5.81 kg (12.80 lbs) CCS-720DT-48S-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.638 kg (10.22 lbs) CCS-720DT-48S-2R 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.638 kg (10.22 lbs) CCS-720DT-24S-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.356 kg (9.60 lbs) CCS-720DT-24S-2R 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.356 kg (9.60 lbs) CCS-720DF-48Y-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.8 kg (10.58 lbs) CCS-720DF-48Y-DC-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.77 kg (10.51 lbs) CCS-720DP-24ZS-2F 440 x 43.5 x 430 mm (17.32 x 1.71 x 16.92 inches) 6.6 kg (14.55 lbs) CCS-720DP-48ZS-2F 440 x 43.5 x 430 mm (17.32 x 1.71 x 16.92 inches) 8 kg (17.63 lbs) CCS-720DF-48Y-M-S-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.5 kg (9.92 lbs) CCS-720DP-48S-M-S-2F 440 x 43.5 x 430 mm (17.32 x 1.71 x 16.92 inches) 6.73 kg (14.83 lbs) CCS-720DP-24S-M-S-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 5.81 kg (12.80 lbs) CCS-720DT-24S-M-S-2F 440 x 43.5 x 330 mm (17.32 x 1.71 x 12.99 inches) 4.356 kg (9.60 lbs)

Table 2: Ethernet Switch Specifications (Operational and Storage) Device Operating Temperature Storage Temperature Operating AltitudeRelative Humidity CCS-720DP-48S 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DT-48S 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DP-24S 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DT-24S 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DF-48Y 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DF-48Y- DC 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DP-24ZS 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing) CCS-720DP-48ZS 0 to 40°C (32° to 104°F) -25 to 70°C (-13 to 158F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing)

Table 3: Ethernet Switch Specifications (Power Ratings) Device Input Power Rating CCS-720DP-48S-2F 100 - 240V~, 10 - 5A, 50/60 Hz CCS-720DP-48S-M-S-2F 100 - 240V~, 10 - 5A, 50/60 Hz CCS-720DP-24S-2F 100 - 240V~, 6 - 3A, 50/60 Hz CCS-720DP-24S-M-S-2F 100 - 240V~, 6 - 3A, 50/60 Hz CCS-720DT-48S-2F 100 - 240V~, 1.2-0.6A, 50/60 Hz CCS-720DT-48S-2R 100 - 240V~, 1.2-0.6A, 50/60 Hz CCS-720DT-24S-2F 100 - 240V~, 1-0.5A, 50/60 Hz CCS-720DT-24S-M-S-2F 100 - 240V~, 1-0.5A, 50/60 Hz CCS-720DT-24S-2R 100 - 240V~, 1-0.5A, 50/60 Hz CCS-720DF-48Y-2F 100 - 240V~, 2.2-1.1A, 50/60 Hz CCS-720DF-48Y-M-S-2F 100 - 240V~, 2.2-1.1A, 50/60 Hz CCS-720DF-48Y-DC-2F -48 to -60VDC, 4.5-3.6A CCS-720DP-24ZS-2F 100 - 240V~, 10-5A, 50/60 Hz CCS-720DP-48ZS-2F 100 - 240V~, 10A, 50/60 Hz

Table 4: Ethernet Switch Specifications (PoE Power Budget) Device PoE Power Budget CCS-720DP-48S 745W CCS-720DT-48S N/A CCS-720DP-24S 380W CCS-720DT-24S N/A CCS-720DF-48Y N/A CCS-720DF-48Y-DC N/A CCS-720DP-24ZS 730W CCS-720DP-48ZS 120V: 2x700W 240V: 2x1440W CCS-720DP-48ZS 120V: 700W 240V: 1500W

Table 5: Ethernet Switch Specifications (System Configurations) Device PoE Ports Downlink Ports Uplink Ports Airflow Power Supply Fan CCS-720DP-48S-2F 30W 48x1G RJ45 4x10G SFP+ Front to rear2 4 CCS-720DP-48S-M-S-2F 30W 48x1G RJ45 4x10G SFP+ Front to rear2 4 CCS-720DP-24S-2F 30W 24x1G RJ45 4x10G SFP+ Front to rear2 3 CCS-720DP-24S-M-S-2F 30W 24x1G RJ45 4x10G SFP+ Front to rear2 3 CCS-720DT-48S-2F N/A 48x1G RJ45 4x10G SFP+ Front to rear2 2 CCS-720DT-48S-2R N/A 48x1G RJ45 4x10G SFP+ Rear to Front2 2 CCS-720DT-24S-2F N/A 24x1G RJ45 4x10G SFP+ Front to rear2 2 CCS-720DT-24S-M-S-2F N/A 24x1G RJ45 4x10G SFP+ Front to rear2 2 CCS-720DT-24S-2R N/A 24x1G RJ45 4x10G SFP+ Rear to front2 2 CCS-720DF-48Y-2F N/A 48x1G SFP 4x25G SFP28 Front to rear2 3 CCS-720DF-48Y-M-S-2F N/A 48x1G SFP 4x25G SFP28 Front to rear2 3 CCS-720DF-48Y-DC-2F N/A 48x1G SFP 4x25G SFP28 Front to rear2 3 CCS-720DP-24ZS-2F 60W 24x2.5G RJ45 4x10G SFP+ Front to rear2 4 CCS-720DP-48ZS-2F 60W 48x2.5G RJ45 4x10G SFP+ Front to rear2 4

This section describes the initial set up and preparation for installing the switch. The following topics are covered in this section:

  • Site Selection
  • Tools and Parts Required for Installation
  • Electrostatic Discharge (ESD) Precautions

2.1 Site Selection

The following criteria should be considered when selecting a site to install the switch:

  • Temperature and Ventilation: For proper ventilation, install the switch with ample airflow to the front and back of the switch. Important: To prevent the switch from overheating, do not operate it in an area where the ambient temperature exceeds 40°C (104°F). Pour empêcher l'interrupteur de surchauffe, ne pas utiliser il dans une zone où la température ambiante est supérieure à 40°C (104°F).
  • Airflow Orientation: The fans and PSUs determine the airflow direction through the switch. The color of the visible handles or labels indicates the airflow direction. Orient the switch so that airflow flows from the cooler to the hotter aisle. If the airflow direction is not compatible with the installation site, reorient the fan modules to circulate air in the opposite direction.
  • Rack Space: Install the switch in a 19" rack or cabinet. The switch height is 1 RU. The accessory kit provides mounting brackets for two-post racks. When mounting the switch in a partially filled rack, load the rack from bottom to top, with the heaviest equipment at the bottom. Load the switch at the bottom if it is the only item in the rack.
  • Power Requirements: Power requirements vary by switch and power supply model. Refer to Specifications for information regarding your specific device. Important: The power input plug-socket combination must be always accessible; it provides the primary method of disconnecting power from the system. La combinaison de la puissance-prise d'entrée doit être accessible en tout temps; Il fournit le principal moyen de coupure d'alimentation du système. Important: All power connections must be removed to de-energize the unit. Toutes les connexions d'alimentation doivent être enlevées pour hors tension l'appareil.
  • Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes. Verify that the following guidelines are met:
  • Clearance areas to the front and rear panels allow for unrestricted cabling.
  • All front and rear panel indicators are visualizable.
  • Power cords can reach from the power outlet to the connector on the rear panel.

2.2 Tools and Parts Required for Installation

Each device has an accessory kit containing the parts required to install the switch. In addition to the accessory kit, the following tools and equipment are required to install the switch: Two-Post Rack

  • #1 and #3 Phillips head screwdrivers (this may differ based on supplied accessories)
  • Screws or rack mounting nuts and bolts The accessory kit does not include screws for attaching the switch to the equipment rack. When installing the switch into an equipment rack with unthreaded post holes, nuts are also required to secure the switch to the rack posts.

2.3 Electrostatic Discharge (ESD) Precautions

Observe these guidelines to avoid ESD damage when installing or servicing the switch.

  • Assemble or disassemble equipment only in a static-free work area.
  • Use a conductive work surface (such as an anti-static mat) to dissipate static charge.
  • Wear a conductive wrist strap to dissipate static charge accumulation.
  • Minimize handling of assemblies and components.
  • Keep replacement parts in their original static-free packaging.
  • Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
  • Use tools that do not create ESD.

This section provides instructions on how to to rack mount the switch. The following topics are covered in this section:

  • Two-Post Rack Mount

3.1 Two-Post Rack Mount

This section provides instructions for mounting the switch in a two-post rack. To mount the switch onto a two-post rack, assemble the mounting brackets to the chassis, then attach the brackets to the rack posts. It includes:

  • Attaching Mounting Brackets to the Chassis
  • Inserting the Switch into the Rack

3.1.1 Attaching Mounting Brackets to the Chassis

This section describes the steps to attach mounting brackets to the switch chassis. Figure 3-1: Attaching the Mounting Brackets

1 Flat head screw M4x6mm

2 L-bracket (MTL-01066)

Figure 3-2: Attaching the Mounting Brackets (CCS-720DF-48Y-DC) Note: The Extended L-bracket shown in the following image is provided only for the CCS-720DF-48Y- DC model. If required, it can be ordered separately.

2 Extended L-bracket (MTL-05776)

Note: For more information regarding the screw size, refer to Screw Size Details 1. Position the L-bracket or Extended L-bracket (flush, 1.5" offset, or 2.5" offset) by aligning with the chassis holes on both sides of the switch and fixing it with M4x6mm flat head screws. 2. Secure the mounting brackets firmly to the switch.

3.1.2 Inserting the Switch into the Rack

This section describes the steps to insert the switch into the rack. Figure 3-3: Inserting the Switch into the Rack

1 Screw M4x25mm (not included in the kit)

2 Two-post rack

Figure 3-4: Inserting the Switch into the Rack (CCS-720DF-48Y-DC) Note: The Extended L-bracket shown in the following image is provided only for the CCS-720DF-48Y- DC model. If required, it can also be ordered separately.

Note: For more information regarding the screw size, refer to Screw Size Details 1. Lift the chassis, attached with L-brackets, into the rack. 2. Place the switch into the rack by aligning it with the mounting bracket. 3. Position the flanges against the rack posts, as shown in the earlier figure. 4. Attach the bracket flanges to the rack posts.

The Cabling the Switch section includes the following topics:

  • Grounding the Switch
  • Connecting Power Cables
  • Connecting Serial and Management Cables

4.1 Grounding the Switch

This section describes the importance of grounding the device to the data center ground. Normally, the functional grounding of the switch is achieved through the input connection. If you would like to do additional grounding, proceed to the following instructions: Figure 4-1: Grounding the Switch

1 Screw M4 (with washer)

2 Solder terminal lug

3 Grounding point

Note: Grounding wires and grounding lugs are not supplied with the product. The wire size should meet local and national installation requirements. CAUTION : The grounding connection must only be removed if all supply connections are disconnected. 1. Ensure the rack is properly grounded and complies with ETSI ETS 300 253. 2. Verify a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). 3. Attach the solder terminal lug to an 18 AWG minimum grounding wire and connect it to the grounding point on the rear panel of the switch. 4. Tighten the M4 screw to secure the lug to the grounding point. 5. Connect the other end of the wire to the nearby grounded surface.

4.1.1 Grounding Lug Preparation

The following procedure connects the chassis to the data center ground: 1. Prepare the (stranded) copper wiring for the ground wire. 2. Use agency-approved compression (pressure) lugs for wiring terminations. 3. Slip on heat-shrink tubing on the wire end before assembling the lugs on to the wire. 4. Crimp the lugs with the proper tool, and ensure that the tubing extends over the barrel of the lug and the insulation on the wire as shown in the following figure. Figure 4-2: Lug Preparation

1 Insulated wire

2 Heat-shrink tubing

3 Lug (all three terminals)

A ¼" B ½" C ⅝" 5. Shrink the tubing with a heat gun.

4.2 Connecting Power Cables

This section describes the installation requirements for connecting the power cables to the device. Important:

  • Installation of this equipment must comply with local and national electrical codes. Consult with the appropriate regulatory agencies and inspection authorities to assure compliance if necessary. Installation de cet équipement doit être conformes aux codes électriques locaux et nationaux. Si nécessaire, consulter les organismes de réglementation appropriés et des autorités de contrôle pour assurer la conformité.
  • Read all installation instructions before connecting the system to the power source. Lire toutes les instructions d'installation avant de brancher le système à la source d'alimentation.
  • This equipment must be grounded. Never defeat the ground conductor. Cet équipement doit être mis à la terre. Ne jamais modifier le conducteur de terre.
  • This unit requires overcurrent protection.

Cet appareil requiert une protection contre les surintensités.

4.2.1 Connecting AC Power

This section describes how to connect the AC power supply to the device. The AC power supplies are internal to each switch. Power requirements vary by switch. Refer to the Specifications section for information regarding your specific device. Rear Panel section displays the location of the power supplies for a specific device. Power Configurations

  • Non-redundant: Connect power to either of the two power supplies.
  • Redundant : Connect each AC power supply to a circuit that provides the required power. Note: Remove all power cords and wires from the power supplies to power down the switch. Input power and power supply redundancy is dependent on the actual system power draw. Each power supply should be connected to its own input overcurrent protection for maximum input power redundancy. Use power supply cables that comply with IEC-320 and have a C13 plug.

4.2.2 Connecting DC Power

This section describes how to connect the DC power supply to the device. The DC power supplies are internal to each switch. Power requirements vary by switch. Refer to the Specifications section for information regarding your specific device. Rear Panel section displays the location of the power supplies for the specific device. There is a cover over the DC supply terminals. Important:

  • A disconnect device must be provided as part of the installation. Un dispositif de sectionnement doit être fourni dans le cadre de l'installation.
  • Ensure power is removed from DC circuits before performing any installation actions. Locate the disconnect device, circuit breakers, or fuses on DC power lines servicing the circuits. Turn off the power line circuits or remove the fuses. Pouvoir assurer qu'il est retiré de circuits DC avant d'effectuer des actions d'installation . Localiser les disjoncteurs ou des fusibles sur les lignes de courant continu desservant les circuits. Coupez les circuits de lignes d'alimentation ou retirer les fusibles.
  • Wire size must comply with local and national requirements and electrical codes. Use only copper wire. Le calibre du fil doit être conforme aux exigences locales et nationales et les codes électriques. Utiliser du fil de cuivre.
  • Apply the grounding connection prior to installation and remove it after disconnecting the power. Appliquer connexion à la terre à l'interrupteur premier lors de l'installation et de supprimer la dernière alimentation lors du débranchement. Power Configurations
  • Non-redundant: Connect power to either of the two power supplies.
  • Redundant: Connect each DC power supply to a circuit that provides the required power.

4.2.3 Connecting DC Power Supply to Power Source

This section describes connecting the DC power supply to the power source. Important:

  • Wire size must comply with local and national requirements and electrical codes. Use only copper wire. Calibre doit respecter les exigences locales et nationales et les codes de l’électricité. Utiliser seulement du fil de cuivre.
  • Apply the ground connection prior to installation and remove it after disconnecting the power. Appliquer le motif connexion tout d’abord pendant l’installation et supprimer dernière lors du retrait de puissance. To connect a DC power supply to the power source, follow the steps below: 1. Remove the terminal cover to expose the connectors on the terminal block on the face. 2. Attach the appropriate lugs to the source DC wires. Use DC cables with insulated crimp-on spade lugs or crimp-on ring connectors. 3. Connect the DC-input wires to the terminal block in this order: a. Ground cable to the ground connector on the terminal block. b. Negative (–) source DC cable to the negative (–) connector on the terminal block. c. Positive (+) source DC cable to the positive (+) connector on the terminal block. d. Torque the screws as specified in the following table. Table 6: Wiring, Lug, and Tightening Torques for DC PSUs Wire Size Tightening Torque AWG mm2 Lug Type N.m lbs 14 to 18 1.5 to 0.75 ring 0.8 7.0 4. Replace the terminal cover.

4.3 Connecting Serial and Management Cables

This section describes the type of cables required to connect the device. The accessory kit includes the following cables:

  • RJ-45 to DB-9 serial adapter cable
  • RJ-45 Ethernet cable The following RJ-45 to DB-9 table lists the pin connections of the RJ-45 to DB-9 adapter cable.

Table 7: RJ-45 to DB-9 Connections RJ-45 DB-9 RJ-45 DB-9 RTS 1 8 CTS GND 5 5 GND DTR 2 6 DSR RXD 6 3 TXD TXD 3 2 RXD DSR 7 4 DTR GND 4 5 GND CTS 8 7 RTS Figure 4-3: Front Panel Ports

1 Ethernet Management Port

2 USB Port

3 Console Serial Port

Connect the front panel ports as described below:

  • Console (Serial) Port: Connect to a computer with the RJ-45 to DB-9 serial adapter cable. The switch uses the following default settings:
  • 9600 baud
  • No flow control
  • 1 stop bit
  • No parity bits
  • 8 data bits
  • Ethernet Management Port: Connect to 10/100/1000 management network with RJ-45 Ethernet cable.
  • USB Port: The USB port may be used for software or configuration updates. Important: Excessive bending can damage interface cables, especially optical cables. Flexion excessive peut endommager les câbles d'interface, notamment des câbles optiques.

Arista switches ship from the factory in Zero Touch Provisioning (ZTP) mode. ZTP configures the switch without user intervention by downloading a startup configuration file or a boot script from a location specified by a DHCP server. To manually configure a switch, ZTP is bypassed. The initial configuration provides one username (admin) that is accessible only through the console port because it has no password. When bypassing ZTP, initial switch access requires logging in as admin, with no password, through the console port. Then you can configure an admin password and other password protected usernames. This manual configuration procedure cancels ZTP mode, logs into the switch, assigns a password to admin, assigns an IP address to the management port, and defines a default route to a network gateway. 1. Provide power to the switch (Connecting Power Cables). 2. Connect the console port to a PC (Connecting Serial and Management Cables). As the switch boots without a startup-config file, it displays the following through the console: The device is in Zero Touch Provisioning mode and is attempting to download the startup-config from a remote system. The device will not be fully functional until either a valid startup-config is downloaded from a remote system or Zero Touch Provisioning is cancelled. To cancel Zero Touch Provisioning, login as admin and type 'zerotouch cancel' at the CLI. localhost login: 3. Log into the switch by typing admin at the login prompt. localhost login: admin 4. Cancel ZTP mode by typing zerotouch cancel. IMPORTANT: This step initiates a switch reboot. localhost>zerotouch cancel 5. After the switch boots, log into the switch again by typing admin at the login prompt. Arista EOS localhost login:admin Last login: Fri Mar 15 13:17:13 on console 6. Enter global configuration mode. localhost>enable localhost#config 7. Assign a password to the admin username with the username secret command. localhost(config)#username admin secret pxq123 8. Configure a default route to the network gateway. localhost(config)#interface management 1

localhost(config-if-Ma1/1)#ip address 192.0.2.8/24 10. Save the configuration by typing write memory or copy running-config startup-config. localhost#copy running-config startup-config 11. When the management port IP address is configured, use this command to access the switch from a host, using the address configured in step 9: ssh admin@192.0.2.8 Refer to the Arista Networks User Manual for complete switch configuration information.

This section describes the front panel LED status of the device. LED Status Indicators

Table 8: LED Status LED Name LED State Device Status Off No power or in the midst of a power cycle. Blinking Green The system is powering up. Green The system is operating in a normal initialization sequence. Normal operations. Blue The locator function is active. System Status LED Amber The system is malfunctioning. The system is overheating, or temperature sensors have recorded passing the software-defined critical threshold. The switch will automatically execute a “graceful shutdown” shortly. Off Not connected to the cloud. Green The system is connected to the cloud. Cloud Connect Status LED Amber Problem connecting to the cloud. Green All fan modules are operating normally.Fan Status LED Amber The single fan module is malfunctioning. Off The power supply unit is not available. Green The power supply unit is fully functional. Power Supply Status LED Amber The power supply unit has a fault. Off Normal mode is not selectedPort Normal Mode LED Green Port LED is selected to indicate port link status (normal mode). Off PoE mode is not selected.Port PoE Mode LED (CCS-720DP-48S, CCS-720DP-24S, CCS-720DP-24ZS, CCS-720DP-48ZS) Green Port LED is selected to indicate port PoE status. Off Speed mode is not selected.Port Speed Mode LED Green Port LED is selected to indicate port speed.

Table 9: Port LED Modes Port LEDs Normal Mode PoE Mode Speed Mode Off Port link is downOff No PoE Blinking Amber10M Green Port link is up Blinking Amber 15W Amber 100M 1GE RJ45 Port LED Amber Port is software disabled Amber 30W Green 1G Off Port link is downOff No PoE Blinking Amber100M Green Port link is up Blinking Amber 15W Amber 1G Amber Port is software disabled Amber 30W Green 2.5G 2.5GE RJ45 Port LED Blinking Green 60W Off Port link is down Blinking Amber100M Green Port link is up Amber 1G SFP+ Port LED Amber Port is software disabled Off No PoE Green 10G Off Port link is down Blinking Amber1G Green Port link is up Amber 10G SFP28 Port LED Amber Port is software disabled Off No PoE Green 25G

This section lists the installation parts contained in the switch accessory kit. Each device has an accessory kit that contains the necessary parts to install the switch. Two-post Rack Mount The following accessories are available along with the device:

  • Figure 7-1: Two-post Rack Mount Kit Parts

1 L-bracket (left)

2 L-bracket (right)

3 Flat head screw M4x6mm

Figure 7-2: Two-post Rack Mount Kit Parts (CCS-720DF-48Y-DC)

  • Console Cables
  • CBL-00100 RJ45 <-> RJ45 CAT5E ethernet cable
  • CBL-00002 RJ45 <-> DB9 console cable
  • Power cable (specified during time of purchase as it's country-specific or no power cord) Optional Accessories The following are the optional accessories and should be ordered separately if required:

KIT-720 Spare Accessory kit for Arista 720D Series 1RU Switches KIT-7010-4Post Spare 4-post rack mount kit for 7010 switches SKU and Product Details The following are the list of SKU numbers related to the respective product.

Table 10: SKU and Product Details SKU Product Description CCS-720DP-48S-2F Arista 720DP, 48x1G PoE, 4x10G SFP+ switch, front to rear air, 2x950W AC CCS-720DP-48S-M-S-2F Arista 720DP, 48x1G POE, 4x10G SFP+ switch, expanded memory, front to rear air, 2x950W AC CCS-720DP-24S-2F Arista 720DP, 24x1G PoE, 4x10G SFP+ switch, front to rear air, 2x460W AC CCS-720DP-24S-M-S-2F Arista 720DP, 24x1G POE, 4x10G SFP+ switch, expanded memory, front to rear air, 2x460W AC CCS-720DT-48S-2F Arista 720DT, 48x1G, 4x10G SFP+ switch, front to rear air, 2x100W AC CCS-720DT-48S-2R Arista 720DT, 48x1G, 4x10G SFP+ switch, rear to front air, 2x100W AC CCS-720DT-24S-2F Arista 720DT, 24x1G, 4x10G SFP+ switch, front to rear air, 2x100W AC CCS-720DT-24S-M-S-2F Arista 720DT, 24x1G, 4x10G SFP+ switch, expanded memory, front to rear air, 2x100W AC CCS-720DT-24S-2R Arista 720DT, 24x1G, 4x10G SFP+ switch, rear to front air, 2x100W AC CCS-720DF-48Y-2F Arista 720DF, 48x1G SFP, 4x25G SFP28 switch, front to rear air, 2x200W AC CCS-720DF-48Y-M-S-2F Arista 720DF, 48x1G SFP, 4x25G SFP28 switch, expanded memory, front to rear air, 2x200W AC CCS-720DP-24ZS-2F Arista 720DP, 24x2.5G PoE, 4x10G SFP+ switch, front to rear air, 2x950W AC CCS-720DP-48ZS-2F Arista 720DP, 48x2.5G PoE, 4x10G SFP+ switch, front to rear air, 2x1800W AC CCS-720DF-48Y-DC-2F Arista 720DF, 48x1G SFP, 4x25G SFP28 switch, front to rear air, 2x240W DC

This section describes the front panel of the Ethernet Switch.

8.1 CCS-720DP-48S

The CCS-720DP-48S front panel includes the following key components: Figure 8-1: CCS-720DP-48S Front Panel

1 System Status LEDs 6 4x10G SFP+ Ports

2 RJ45 Ethernet Management Port 7 SFP+ Port LEDs

3 USB Port 8 48x1G PoE Ports

4 Console Port 9 Mode Button

5 Port LEDs 10 Mode Status LEDs

8.2 CCS-720DP-48S-M-S

The CCS-720DP-48S-M-S front panel includes the following key components: Figure 8-2: CCS-720DP-48S-M-S Front Panel

8.3 CCS-720DP-24S

The CCS-720DP-24S front panel includes the following key components: Figure 8-3: CCS-720DP-24S-M-S Front Panel

3 USB Port 8 24x1G PoE Ports

8.4 CCS-720DP-24S-M-S

The CCS-720DP-24S-M-S front panel includes the following key components: Figure 8-4: CCS-720DP-24S-M-S Front Panel

8.5 CCS-720DT-48S

The CCS-720DT-48S front panel includes the following key components: Figure 8-5: CCS-720DT-48S Front Panel

8.6 CCS-720DT-24S

The CCS-720DT-24S front panel includes the following key components: Figure 8-6: CCS-720DT-24S Front Panel

3 USB Port 8 24x1G Ports

8.7 CCS-720DT-24S-M-S

The CCS-720DT-24S-M-S front panel includes the following key components: Figure 8-7: CCS-720DT-24S-M-S Front Panel

8.8 CCS-720DF-48Y

The CCS-720DF-48Y front panel includes the following key components: Figure 8-8: CCS-720DF-48Y Front Panel

1 System Status LEDs 6 4x25G SFP28 Ports

2 RJ45 Ethernet Management Port 7 SFP28 Port LEDs

3 USB Port 8 48x1G SFP Ports

8.9 CCS-720DF-48Y-M-S

The CCS-720DF-48Y-M-S front panel includes the following key components: Figure 8-9: CCS-720DF-48Y-M-S Front Panel

8.10 CCS-720DP-24ZS

The CCS-720DP-24ZS front panel includes the following key components: Figure 8-10: CCS-720DP-24ZS Front Panel 3 USB Port 8 24x2.5G PoE Ports

8.11 CCS-720DP-48ZS

The CCS-720DP-48ZS front panel includes the following key components: Figure 8-11: CCS-720DP-48ZS Front Panel 3 USB Port 8 48x2.5G PoE Ports

The section describes the rear panel of the Ethernet Switch.

9.1 CCS-720DP-48S-2F / CCS-720DP-48S-M-S-2F

The CCS-720DP-48S-2F / CCS-720DP-48S-M-S-2F rear panel includes the following key components: Figure 9-1: CCS-720DP-48S-2F / CCS-720DP-48S-M-S-2F Rear Panel

1 Power supply 1 (PS1) 5 Fan 3

2 Functional Grounding Point 6 Fan 4

3 Fan 1 7 Power Supply 2 (PS2)

4 Fan 2

9.2 CCS-720DP-24S-2F / CCS-720DP-24S-M-S-2F

The CCS-720DP-24S-2F / CCS-720DP-24S-M-S-2F rear panel includes the following key components: Figure 9-2: CCS-720DP-24S-2F / CCS-720DP-24S-M-S-2F Rear Panel

1 Power supply 1 (PS1) 4 Fan 2

2 Functional Grounding Point 5 Fan 3

3 Fan 1 6 Power Supply 2 (PS2)

9.3 CCS-720DT-48S-2F

The CCS-720DT-48S-2F rear panel includes the following key components: Figure 9-3: CCS-720DT-48S-2F Rear Panel

2 Functional Grounding Point 5 Power Supply 2 (PS2)

3 Fan 1

9.4 CCS-720DT-24S-2F / CCS-720DT-24S-M-S-2F

The CCS-720DT-24S-2F / CCS-720DT-24S-M-S-2F rear panel includes the following key components: Figure 9-4: CCS-720DT-24S-2F / CCS-720DT-24S-M-S-2F Rear Panel

9.5 CCS-720DT-24S-2R

The CCS-720DT-24S-2R rear panel includes the following key components: Figure 9-5: CCS-720DT-24S-2R Rear Panel

9.6 CCS-720DT-48S-2R

The CCS-720DT-48S-2R rear panel includes the following key components: Figure 9-6: CCS-720DT-48S-2R Rear Panel

9.7 CCS-720DF-48Y-2F / CCS-720DF-48Y-M-S-2F

The CCS-720DF-48Y-2F / CCS-720DF-48Y-M-S-2F rear panel includes the following key components: Figure 9-7: CCS-720DF-48Y-2F / CCS-720DF-48Y-M-S-2F Rear Panel

9.8 CCS-720DF-48Y-DC-2F

The CCS-720DF-48Y-DC-2F rear panel includes the following key components: Figure 9-8: CCS-720DF-48Y-DC-2F Rear Panel

9.9 CCS-720DP-24ZS-2F

The CCS-720DP-24ZS-2F rear panel includes the following key components: Figure 9-9: CCS-720DP-24ZS-2F Rear Panel

9.10 CCS-720DP-48ZS-2F

The CCS-720DP-48ZS-2F rear panel includes the following key components: Figure 9-10: CCS-720DP-48ZS-2F Rear Panel

This section describes the functionality of the mode button located on the front panel of the switch. Figure A-1: Mode Button States The mode button port LEDs will transition to different modes as listed below when the user presses the mode button for less than 2 seconds, and the same is indicated by the corresponding mode status LED.

  • Normal Mode
  • PoE Mode
  • Speed Mode In addition to controlling the port/mode LEDs, the button can trigger other actions, including a hard reset and a factory reset. To access these actions, it is required to long-press the button as shown in the Figure 31: Mode Button States.
  • Entering Reset States: If you press and hold the button for more than 2 seconds, all the 3 mode status LEDs will flash to indicate the transition from regular operating states to reset states. If the button is released before 5 seconds, no action will occur, and the system will return to its previous mode (normal, PoE, or link speed).
  • Hard Reset: If you press and hold the button for about 5 to 15 seconds, it will trigger a hard reset of the system 2 seconds later.
  • Factory Reset: If you press and hold the button for about 15 seconds or longer, it will trigger a hard reset of the system 2 seconds later. In addition, the system will also trigger factory reset on system configuration.

This section lists the Regulatory Model Numbers (RMNs) of the Ethernet switches described in this guide. Table 11: Regulatory Model Numbers Product Number Regulatory Model Number (RMN) CCS-720DP-48S-2F CCS-720DP-48S-M-S-2F AN1755 CCS-720DP-24S-2F CCS-720DP-24S-M-S-2F AN1756 CCS-720DT-48S-2F AN1784 CCS-720DT-48S-2R AN1784 CCS-720DT-24S-2F CCS-720DT-24S-M-S-2F AN1785 CCS-720DT-24S-2R AN1785 CCS-720DF-48Y-2F CCS-720DF-48Y-M-S-2F AN1757 CCS-720DP-24ZS-2F AN1754 CCS-720DP-48ZS-2F AN1753 CCS-720DF-48Y-DC-2F AN2211

This section describes the detailed screw size information required for mounting the switch. Refer to Rack Mounting the Switch

This appendix provides Taiwan BSMI Class A Statement information for switches described in this guide. Figure D-1: Taiwan BSMI Class A Statement

This appendix provides Taiwan and China RoHS information for the Ethernet switches described in this guide.