3M™ Novec™ 71IPA Engineered Fluid is a hydrofluoroether, methoxy-nonafluorobutane (C4F9OCH3), in an azeotrope-like formulation with isopropanol. This fluid is ideal for light-duty cleaning and degreasing tasks, and is intended to replace ozone-depleting materials such as CFC-113, HCFC-14lb and 1,1,1-trichloroethane in many applications. It has zero ozone depletion potential and other favorable environmental properties (see Table 2). Novec 71IPA fluid has a low toxicological profile, with a time-weighted average exposure guideline of 750 ppm for the 3M ™ Novec™ 7100 Engineered Fluid component (eight hour average). The increased polar soil solvency and low surface tension, nonflammability and constant composition during boiling of Novec 71IPA fluid make it ideal for precision and specialty cleaning and rinsing for removal of particulate, fingerprints and light soils from metal, plastic and glass parts.

Applications

  • Precision cleaning, rinsing and drying agent - Light-duty cleaning of oils, greases, waxes, fingerprints
  • Use in combination with co-solvents for “no-clean flux” residue removal. 3M™ Novec™ 71IPA Engineered Fluid Product Information Material Description Ingredients 3M™Novec™ 71IPA Engineered Fluid Methyl Nonafluorobutyl Ether (C4F9OCH3) 95.5% by weight Isopropanol 4.5% by weight Appearance Clear, colorless 1Novec 7100 fluid (C4F9OCH3) consists of two inseparable isomers with essentially identical properties. These are (CF 3)2CFCF2OCH3 (CAS No. 163702-08-7) and CF3CF2CF2CF2OCH3 (CAS No. 163702-07-6). All values determined at 25°C unless otherwise specified Not for specification purposes Typical Physical Properties Table 1 Properties 3M™ Novec™ 7100 Engineered Fluid 3M™Novec™ 71IPA Engineered Fluid CFC-113 HCFC-141b 1,1,1-TCA Formulation C4F9OCH3 Azeotrope1 C2Cl3F3 CCl2FCH3 C3Cl2HF5 Boiling Point (°C) 61 54.8 48 32 74 Freeze Point (°C) -135 -422 -35 -103 -39 Vapor Pressure (mmHg) 202 207 331 569 128 Heat of Vaporization (cal/g @ boiling point) 30 39.5 35 53.3 58 1 95% 3M™ Novec™ 7100 (C4F9OCH3), 5% IPA

2 Critical Solution Temperature

Environmental and Safety Properties Table 2 Properties 3M™ Novec™ 7100 Engineered Fluid 3M™Novec™ 71IPA Engineered Fluid CFC-113 HCFC-141b 1,1,1-TCA Global Warming Potential2 320 310 6000 700 140 Flash Point None None None None None Atmospheric Lifetime, Years 4.1 4.1 85 9.2 4.8 Exposure Guidelines, ppm (8 hr. time-weighted average) 750 750/400* 1000 400 350 Flammability Range in Air None 4.0 - 16.7% None 7.6 - 17.7% 6 - 15% 1 CFC-11=1.0 2 GWP–100 year ITH, CO2 = 1.0 *Isopropyl alcohol (IPA) has an 8 hr. TWA exposure guidelines of 400 ppm 3M™ Novec™ 71IPA Engineered Fluid Data compiled from published information. Not for specification purposes. All values @ 25°C unless otherwise specified. Materials Compatibility Testing of 3M™ Novec™ 71IPA Engineered Fluid demonstrates compatibility with a wide range of metals, plastics and elastomers, similar to the performance of perfluorinated liquids. Good compatibility with particularly sensitive plastics such as polycarbonate and PMMA indicates utility in cleaning of assemblies containing many composite materials. As with most fluorinated liquids, Novec 71IPA fluid will absorb into fluorinated plastics and elastomers over longer exposures. Metals Plastics Elastomers Aluminum Acrylic (PMMA) Butyl Rubber* Copper Polyethylene Natural Rubber Carbon Steel Polypropylene Nitrile Rubber

302 Stainless Steel Polycarbonate EPDM

Compatible after one hour exposure at boiling temperature. Exceptions: Some swelling of PTFE and Silicone Rubber. Some surface oxidation of copper during heat aging. *Butyl Rubber best for extended exposure >1 month. More 3M™ Novec™ Engineered Fluids Properties 3M™ Novec™ 7100 Engineered Fluid 3M™ Novec™ 7200 Engineered Fluid 3M™ Novec™ 71DE Engineered Fluid 3M™ Novec™ 71DA Engineered Fluid Formulation Methoxynonafluoro-butane Ethoxynonafluoro-butane Novec 7100 with Trans-1, 2-dichloroethylene (Azeotrope) Novec 7100 with Trans-1, 2-dichloroethylene and Ethanol (Azeotrope) Boiling Point (°C) 61 76 128 40 Typical Light cleaning, formulations, process solvent cold cleaner, movie film cleaning, process solvent medium weight oil cleaning, liquid oxygen cleaning flux removal, vapor degreasing

Regulations on Chlorine-Containing Solvents Table 3 Regulation Trans-1,2- dichloroethylene Trichloroethylene Perchloroethylene Methylene Chloride VOC Designation Yes Yes Yes No Regulated if Emitted into Water Yes Yes Yes Yes Hazardous Air Pollutant No Yes Yes Yes Annual Reporting (EPCRA 313) (SARA) No Yes Yes Yes OSHA List of toxins/carcinogens No Yes Yes Yes Environmental Policy 3M will continue to recognize and exercise its responsibility to prevent pollution at the source wherever and whenever possible; develop products that will have a minimal effect on the environment; conserve natural resources through the use of reclamation and other appropriate methods; assure that its facilities and products meet and sustain the regulations of all federal, state and local environmental agencies; assist, wherever possible, governmental agencies and other official organizations engaged in environmental activities. Safety and Handling Before using this product, please read the current product Material Data Safety Sheet (available through your 3M sales or technical service representative) and the precautionary statement on the product package. Follow all applicable precautions and directions. Novec 71IPA fluid is characterized as having no closed cup flash point, or open cup flash point and no sustained burning per ASTM D4206-86 (<1 second) and is safe to use under normal operating conditions. The product has flame limits of 4.0% to 16.7% (by volume), similar to materials such as HCFC-141b and 1,1,1-TCA which have been used safely in this application for many years. This fluid is highly resistant to thermal breakdown and hydrolysis in storage and during use. A flammable mixture can form during co-solvent boil down in a vapor degreaser. Products of thermal decomposition may cause irritation. Recovery of Novec 71IPA fluid from a co-solvent cleaning process by boil down should only be conducted in equipment designed and approved for handling flammable mixtures. Use of a desiccant is recommended in the water separator. Detailed handling procedures are provided in the Material Safety Data Sheet. Consult your 3M representative for additional information on the proper recovery and disposal of Novec 71IPA fluid. Data compiled from published information. Not for specification purposes.

Recycle and Disposal Options Used Fluid Return Program 3M offers a program for free pickup and return of used 3M specialty fluids in the U.S. A pre-negotiated handling agreement between users and our authorized service provider offers users broad protection against future liability for used 3M product. The fluid return program is covered by independent third-party financial and environmental audits of treatment, storage and disposal facilities. Necessary documentation is provided. A minimum of 30 gallons of used 3M specialty fluid is required for participation in this free program. For additional information on the 3M Used Fluid Return Program, contact your local 3M representative or call 3M Customer Service at 800.810.8513. Resources 3M™ Novec™ Engineered Fluids are supported by global sales, technical and customer service resources, with technical service laboratories in the U.S., Europe, Japan, Latin America and Southeast Asia. Users benefit from 3M’s broad technology base and continuing attention to product development, performance, safety and environmental issues. For additional technical information on 3M™ Novec™ 71IPA Engineered Fluid in the United States or for the name of a local authorized distributor, call 3M Electronics Markets Materials Division: 800 810 8513. Please recycle. Printed in USA. Issued: 9/09 © 3M 2009. All rights reserved. 7012HB 98-0212-2671-1 3M™ Novec™ 71IPA Engineered Fluid 3M and Novec are trademarks of 3M Company. Used under license by 3M subsidiaries and affiliates. Product Use: All statements, technical information and recommendations contained in this document are based on tests or experience that 3M believes are reliable. However, many factors beyond 3M’s control can affect the use and performance of a 3M product in a particular application, including conditions under which the product is used and the time and environmental conditions in which the product is expected to perform. Since these factors are uniquely within the user’s knowledge and control, it is essential that the user evaluate the 3M product to determine whether it is fit for a particular purpose and suitable for the user’s method of application. Warranty and Limited Remedy: Unless stated otherwise in 3M’s product literature, packaging inserts or product packaging for individual products, 3M warrants that each 3M product meets the applicable specifications at the time 3M ships the product. Individual products may have additional or different warranties as stated on product literature, package inserts or product packages. 3M MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user’s application. If the 3M product is defective within the warranty period, your exclusive remedy and 3M’s and seller’s sole obligation will be, at 3M’s option, to replace the product or refund the purchase price. Limitation Of Liability: Except where prohibited b.incidental, or consequential regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. The Novec brand is the hallmark for a variety of patented 3M products. Although each has its own unique formula and performance properties, all Novec products are designed in common to address the need for safe, effective, sustainable solutions in industry-specific applications. These include precision and electronics cleaning, heat transfer, fire protection, lubricant deposition and several specialty chemical applications. The 3M™ Novec™ Brand Family 3M™ Novec™ Engineered Fluids 3M™ Novec™ Aerosol Cleaners 3M™ Novec™ 1230 Fire Protection Fluid 3M™ Novec™ Electronic Coatings 3M™ Novec™ Electronic Surfactants United States 3M Electronics Markets Materials Division 800 810 8513 China 3M China Ltd. 86 21 6275 3535 Europe 3M Belgium N.V. 32 3 250 7521 Japan Sumitomo 3M Limited 813 3709 8250 Korea 3M Korea Limited 82 2 3771 4114 Singapore 3M Singapore Pte. Ltd. 65 64508888 Taiwan 3M Taiwan Limited 886 2 2704 9011 Electronics Markets Materials Division 3M Center, Building 224-3N-11 St. Paul, MN 55144-1000 www.3M.com/novec 1-800-810-8513