7000 BULGINLIMITED | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 8
Technical content
47 Buccaneer for Power
7000 Series Buccaneer
The all plastic and metal construction of the
7000 Series Buccaneer - circular connectors
that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently tested to IP66, IP68 & IP69K standards, they are ideal for applications where ingress of dust and water must be avoided and where ease of connection, space and appearance are important considerations. Less than 1/4 Turn locking mechanism Secure, quick connector mating and release Positive feedback on locking mechanism Confidence that connector is correctly mated and sealed IP66, IP68 and IP69K when mated Suitable for a wide range of dust and water borne environments All plastic body version; UL94-V0 rated, UV stable, halogen free Light-weight, self-extinguishing material suitable for long-term outdoor use Flex, flex in-line & panel mount body styles,with sealing caps Complete family of products maintain sealing integrity in all styles Polarisation and visual alignment features Aids the correct mating of connectors 2 to 32 poles – up to 25A, 600V rated Suitable for mains power to signal applications ‘Scoop proof’ contacts Prevents damage through mis-mating – ideal for ‘blind mating’
applications
cULs, UL, VDE approvals Internationally recognised certification (pending) Screw, Crimp and Solder terminations available EN60068-2-52 Test Kb Salt Mist (Cyclic) Marine Severity Level 1
In-line Flex Cable Connector Front Panel Mounting Connector PXP7010 PXP7011 PXP7012 Mates with In-Line Flex or Panel Mounting versions PXP7011 & PXP7012 Quick turn locking ring Pin or socket versions Leading earth on 3 pole connectors 2, 3, 6, 10 & 32 pole Screw solder and crimp termination Mates with Flex Cable connectors PXP7010 Front panel mounting Single hole fixing Pin or socket versions Leading earth on 3 pole connectors 2, 3, 6, 10 and 32 pole Screw solder and crimp termination Screw Screw Screw Crimp / Solder Crimp / Solder Screw Screw Screw Crimp / Solder Crimp / Solder Screw Screw Screw Crimp / Solder Crimp / Solder PXP7010/02P/ST PXP7010/03P/ST PXP7010/06P/ST PXP7010/10P/CR PXP7010/32P/CR PXP7011/02P/ST PXP7011/03P/ST PXP7011/06P/ST PXP7011/10P/CR PXP7011/32P/CR PXP7012/02P/ST PXP7012/03P/ST PXP7012/06P/ST PXP7012/10P/CR PXP7012/32P/CR PXP7010/02S/ST PXP7010/03S/ST PXP7010/06S/ST PXP7010/10S/CR PXP7010/32S/CR PXP7011/02S/ST PXP7011/03S/ST PXP7011/06S/ST PXP7011/10S/CR PXP7011/32S/CR PXP7012/02S/ST PXP7012/03S/ST PXP7012/06S/ST PXP7012/10S/CR PXP7012/32S/CR Supplied Fitted Supplied Fitted Supplied Fitted Contact Required Contact Required Supplied Fitted Supplied Fitted Supplied Fitted Contact Required Contact Required Supplied Fitted Supplied Fitted Supplied Fitted Contact Required Contact Required Mates with Flex Cable connector PXP7010 For in-line cable connection Pin or socket versions Leading earth on 3 pole connectors 2, 3, 6, 10 and 32 pole Screw solder and crimp termination Poles Poles Poles Termination Termination Termination Pin Contacts Pin Contacts Pin Contacts Socket Contacts Socket Contacts Socket Contacts Contacts Contacts Contacts
49 Buccaneer for Power
In-line Flex Cable Connector Front Panel Mounting Connector PXM7010 PXM7011 PXM7012 Mates with In-Line Flex or Panel Mounting versions PXM7011 & PXM7012 Quick turn locking ring Pin or socket versions Leading earth on 3 pole connectors 2, 3, 6, 10 & 32 pole Screw solder and crimp termination Cable braid termination accessory option, add /SNsuffix Mates with Flex Cable connector PXM7010 For in-line cable connection Pin or socket versions Leading earth on 3 pole connectors 2, 3, 6, 10 and 32 pole Screw solder and crimp termination Cable braid termination accessory option, add /SNsuffix Mates with Flex Cable connectors PXM7010 Front panel mounting Single hole fixing Pin or socket versions Leading earth on 3 pole connectors 2, 3, 6, 10 and 32 pole Screw solder and crimp termination Screw Screw Screw Crimp / Solder Crimp / Solder Screw Screw Screw Crimp / Solder Crimp / Solder Screw Screw Screw Crimp / Solder Crimp / Solder PXM7010/02P/ST PXM7010/03P/ST PXM7010/06P/ST PXM7010/10P/CR PXM7010/32P/CR PXM7011/02P/ST PXM7011/03P/ST PXM7011/06P/ST PXM7011/10P/CR PXM7011/32P/CR PXM7012/02P/ST PXM7012/03P/ST PXM7012/06P/ST PXM7012/10P/CR PXM7012/32P/CR PXM7010/02S/ST PXM7010/03S/ST PXM7010/06S/ST PXM7010/10S/CR PXM7010/32S/CR PXM7011/02S/ST PXM7011/03S/ST PXM7011/06S/ST PXM7011/10S/CR PXM7011/32S/CR PXM7012/02S/ST PXM7012/03S/ST PXM7012/06S/ST PXM7012/10S/CR PXM7012/32S/CR Supplied Fitted Supplied Fitted Supplied Fitted Contact Required Contact Required Supplied Fitted Supplied Fitted Supplied Fitted Contact Required Contact Required Supplied Fitted Supplied Fitted Supplied Fitted Contact Required Contact Required Poles Poles Poles Termination Termination Termination Pin Contacts Pin Contacts Pin Contacts Socket Contacts Socket Contacts Socket Contacts Contacts Contacts Contacts
Cable Braid Termination Option PXM7090 For cable braid termination Supplied with ty-rap Accessories BUCCANEER FOR POWER Contact Carrier Removal Tool 10 & 32 pole contacts PNo 14025 PNo 14944/SP PNo 14945/SP PNo 15065/SP Gold Plated Current ratings: 10 pole: 10A 32 pole: 2A Crimp Tools for 10 and 32 pole crimp contacts Extraction tool for 10 and 32 pole contacts For removal of all contact carriers Contacts (for 10 pole) (Supplied in packs of 10) Crimp Tooling Extraction Tools Contact Carrier Removal Tool Contacts (for 32 pole) (Supplied in packs of 10) Crimp Solder SolderCrimp Pins Sockets Crimp Tool (10 & 32 pole) Positioner (10 pole) Positioner (32 pole) Extraction tool (10 pole) Extraction tool (32 pole) Contact carrier removal tool (all poles) Pins Sockets SA3544/P SA3544/S SA3623/P SA3623/S SA3622/P SA3622/S PNo. 14025 PNo. 15021/SP PNo. 15019/SP PNo. 14945/SP PNo. 14944/SP PNo. 15065/SP SA3542/P SA3542/S
51 Buccaneer for Power
PXP7088/ * Maintains IP rating of unmat- ed connectors PXP7081: Fits PXP7010 (Flex Connector) PXP7082: Fits PXP7011 (FlexIn-Line Connector) and PXP7012: (Panel Connector) Maintains IP rating of unmat- ed connectors PXM7081: Fits PXM7010 (FlexConnector) PXM7082: Fits PXM7011 (Flex In-Line Connector) and PXP7012: (Panel Connector) PXM7083: Fits PXM7012 (Panel Mounting Connector) Packs of cable glands, cages and gland nuts to suit cables ranges from 5.0 to 15.0mm diameter PXP7088/0507: for cable ranges between 5.0 and 7.0mm PXP7088/0713: for cable ranges between 7.0 and 13.0mm PXP7088/1315: for cable ranges between 13.0 and 15.0mm
Series Designation Series / Body Style No. of Contacts Contacts Type Terminations Cable Entry Size PXM= Metal Series PXP= Plastic Series 7010 = Flex 7011 = Flex In-Line 7012 = Panel 02 = 2 Pole 03 = 3 Pole 06 = 6 Pole 10 = 10 Pole 32 = 32 Pole P = Pin S = Socket ST = Screw Terminal (2, 3, & 6 pole only) CR = Contacts Required (10 & 32 pole only) (for Flex and Flex In- Line connectors only) 0507 = 5-7mm (grey) 0709 = 7-9mm (white) 0911 = 9-11mm (black) 1113 = 11 to 13 mm (yellow) 1315 = 13 to 15 mm (light grey) Examples PXX 7XXX XX XXX XXXXXX Cable Brand Termination Accessory (for Flex and Flex In-Line connectors only) SN - If requires Blank - If not required PXM7010/10/P/CR/0911/SN= Flex cable connector, 10 pole, pin contacts with 9 to 11mm cable glands and braid termination accessory PXM7012/03/S/ST= Front panel mounting connector, 3 pole, socket with screw termination
53 Buccaneer for Power
No Poles: Current Rating: CCC, UL and VDE cUL (pending) Voltage Rating (ac/dc): CCC, VDE (pending) UL, cUL (pending) Contact Resistance: Insulation Resistance: AC Breakdown voltage: 2 pole 3 pole 6 to 32 pole Operating Temp. Range: Approvals (pending): UL (Pending) cULus (Pending) VDE (Pending) CCC (Pending) Specifications BUCCANEER FOR POWER Electrical: 2 3 6 10 32 25A 25A 10A 10A 3A 25A 25A 8A 6A 2A 600V 600V 500V 277V 200V 600V 600V 600V 600V 600V <10mΩ >10⁶MΩ @500V dc >10kV >8kV >5kV –40°C to +120°C UL1977 C22.2 No.182.3-M1987 (R2009) IEC 61984:2009 GB/T11918 and GB/T11919 Body: Colour: Contacts: O Rings & Gaskets: Flammability Rating: Halogen free UV Resistance: RoHS Materials: Plastic Metal Mechanical: Locking mechanism Sealing: Salt Mist (plastic): Salt Mist (metal): Contact Accommodation: 2 & 3 pole screw terminals 6 pole screw 10 pole crimp / solder 32 pole crimp / solder Cable Acceptance: Cable retention force (to BS EN61984): 5 - 9mm dia cable 9 - 15mm dia cable Terminations
2 Pole:
3 Pole:
6 Pole:
10 Pole:
32 Pole:
Tightening Torques: Gland Nut: Panel Nut: Panel Nut Thread Dimensions: Diameter: (over coupling ring) Diameter: (panel hole cut-out) Quarter turn, rapid locking IP66 to EN60529:1992+A2:2013 IP68 to EN60529:1992+A2:2013 (10m depth for 2 weeks) IP69k to DIN 40050-9 EN60068-2-52 Test Kb Salt Mist (Cyclic) Marine Severity Level 1 EN60068-2-11 Test Ka Salt Mist 6.0mm² max 1.00mm² max 18 to 20AWG 22 to 26AWG 5-15mm dia. 80N 100N Screw Terminals Screw Terminals Screw Terminals Crimp / Solder Contacts Crimp / Solder Contacts TBA 1.7Nm (15lbf.in.) M30 x 2-6g 42mm 30mm PC/ PBT Grey Brass, Nickel Plate (Screw and Crimp) Brass, (3A – Gold plated) Silicone UL94 V-0 Yes ISO 4892 part 3 cycle 1 (QUV) Compliant Cast zinc alloy, nickel plated Matt silver Brass, Nickel Plate (Screw and Crimp) Brass, (3A – Gold plated) Silicone Compliant USC
10 7020 6030 50 8040 90 130100 120 14011010 7020 6030 50 8040 90 130100 120 140110
10 Pole, Plastic Body, Crimp Terminal, 18 AWG wire
current applied through all pins simultaneously 7000 Series Current vs. Temperature Characteristics Ambient Temperature °C Current (A) Operating Area 10 7020 6030 50 8040 90 130100 120 140110 2 Pole, Plastic Body, Screw Terminal, 6.0mm2 wire current applied through all pins simultaneously 7000 Series Current vs. Temperature Characteristics Ambient Temperature °C Current (A) Operating Area 10 7020 6030 50 8040 90 130100 120 140110
32 Pole, Plastic Body, Crimp Terminal, 22 AWG wire
current applied through all pins simultaneously 7000 Series Current vs. Temperature Characteristics Ambient Temperature °C Current (A) Operating Area 10 7020 6030 50 8040 90 130100 120 140110 3 Pole, Plastic Body, Screw Terminal, 4.0mm2 wire current applied through all pins simultaneously Operating Area 7000 Series Current vs. Temperature Characteristics Ambient Temperature °C Current (A) 10 7020 6030 50 8040 90 130100 120 14011010 7020 6030 50 8040 90 130100 120 140110 6 Pole, Plastic Body, Screw Terminal, 1.0mm2 wire current applied through all pins simultaneously 7000 Series Current vs. Temperature Characteristics Ambient Temperature °C Current (A) Operating Area The thermal properties of the materials used in the construction of a connector limit the current carrying capacity. There are a number of factors that determine the amount of current that can be handled: contact spacing, size of cable, ambient temperature and the heat that is generated by the current passing through the connector. The maximum current varies with different contact layouts, and because of these factors it is necessary to produce de-rating curves for each pole variant. This de-rating curve is specified in the standard IEC 60512 part 3. De-rating curves are plotted for each contact carrier combination with the current being carried simultaneously by all contacts. These graphs show the heat rise generated as the current is increased. The red line indicates the direct correlation between current applied and the measured temperature rise within the connector. The dotted blue line shows rated current and the green line is derived by applying a factor of 0.8 to the original plot data to give a de-rating curve. The dashed blue line shows the rated current. The shaded area under the 0.8 curve shows the permitted operating area, and allows safe current vs ambient temperature characteristics to be determined. = tested operating limits = de-rated operating limits = rated current