FC-10C GAMEWELL-FCI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

  • Inherently power-limited.
  • Integral digital communicator.
  • Fifteen (15) selectable transmission formats.
  • Up to 100 transmitted events/messages.
  • Fire Drill Function.
  • Integral voltmeter.
  • Fully programmable via integral keypad.
  • Auto-reset supervisory operation.
  • Temporal pattern output per ANSI S3.41.
  • Single person walk test with 256 event walk test memory.
  • Alarm verification.
  • Real-time clock/calendar.
  • 256-Event History with time and date stamp, stored in permanent memory.
  • Zone disable feature via software.
  • Two (2) fully programmable Form “A” relay contact output.
  • Programmable trouble reminder.
  • Surface mount technology.
  • Ground start module (optional).
  • Contact-by-Zone module (optional).
  • Serial annunciator output (optional).
  • Printer interface for on or off-line printing (optional) GAMEWELL-FCI

12 Clintonville Road, Northford, CT 06472 - Tel: 203-484-7161 - Fax: 203-484-7118

Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.

Description

The FC-10C Fire Alarm Control panel is a proven, versa- tile, ten-zone modular control with integral communicator and remote-site upload/download capability. It meets the requirements of NFPA Standard 72 for Central Station, Protected Premises, and Remote (DACT) Supervising Station Fire Alarm Systems. It is Listed to UL Standard 864, inherently power limited and meets all UL transient immunity requirements. The integral communicator includes a wide range of se- lectable transmission formats to communicate to virtually all central stations. Other features of the communicator are: A line-active indicator for each of two phone lines, “Kiss-Off” signal LED, dual “low telephone voltage detect” circuitry, programmable event codes per format and se- lectable/deselectable transmission of up to 100 events. Multiple security techniques allow uploading or download- ing within one minute without affecting normal fire panel functions. Key system information that can be uploaded are: Current System Status, History, Walk Test Files and System Programming. An integral voltmeter allows voltage measurements for Zone, AC line, NAC1, NAC2, resettable power and bat- tery. Housed in a red steel enclosure, the surface mounted unit, (trim ring optional) provides space for two (2) B-7R batteries. The many features of the FC-10C control provide a cost effective approach to systems design, and allow a great degree of flexibility in one enclosure. Many of these fea- tures include two (2) notification appliance circuits (expandable to four) with output expandable from 3.0 to 6.0 amps total. Class A operation is possible with optional modules. Fully programmable via integral keypad, the notification appliance circuits may be programmed Si- lenceable, Non-silenceable, Auto-silence (program 5 to 30 minutes) and Silence Inhibit (60 seconds). Initiating zones may be programmed for process monitor- ing via latching or non-latching contact closure and can be used to monitor high-low temperature, loss of air flow, water level, gas detection, open/close, refrigeration and non-fire related tamper functions. Also programmable are Alarm Presignal Timer, Alarm Verification Timer and Optional Trouble Reminder. FC-10C An ISO 9000-2000 Company

12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118

www.gamewell-fci.com 9020-0459 Rev. G page 2 of 2 Description (Continued) Optional modules are available for ground start opera- tion, trouble reminder and addition of two (2) fully pro- grammable Form “C” relays. An optional serial interface allows for a choice of remote annunciators with switches for Reset, Drill, Silence and Acknowledge. Specifications Operating temperature: 32° - 120° F (0° - 49° C) Relative humidity: 85 % (non-condensing) Dimensions: Door 17 1/8" H x 14 3/4" W (43.46 x 37.36 cm) Backbox 16 7/8" H x 14 1/2" W x 4 1/2" D (42.93 x 36.83 cm x 11.43 cm) Trim Ring 20 1/8" H x 17 5/8" W (50.85 x 44.75 cm)

  • Ademoco 685 • Osborne Hoffman Models 1 / 2
  • Silent Knight 9000 • Radionics 6000/6500
  • ITI-CS-4000 • Sescoa 3000R
  • FBI CP220FB UL Listed Receivers compatible with FC-10C:

Ordering Information

Ten Zone Module, replacement board 700-01216 FC-10TR Trim Ring 700-01192 PRT-24 Printer interface module - provides EIA-232 printer output. Includes cable, DB9F and DB25 adapter. 700-01201 LED-101M RS-485 interface module 700-01202 RZA-10 Remote zone annunciator, 10 zones (requires one (1) LED-101M) Mounts on three-gang box. 700-01203 RZA-10L (Ten zone control communicator) Remote zone annunciator, 10 zone limited. (requires one (1) LED-101M) mounts on three-gang box. 700-01204 RZA-10LS2 Remote zone annunciator, 8 red, 2 yellow LEDs (requires one (1) LED-101M) mounts on three-gang box. 700-01205 ACM-8RF Eight-relay module (contact-by-zone) 700-01206 CAC-10F Class “A” initiating circuit converter module 700-01207 NAC-REM Two NAC/two form “C” add-on module 700-01213 SK-10C Software kit (upload/download utility) 700-01222 120 VAC, 100 VA transformer, ex- pands NAC power from 3.0 to 6.0 amperes and system power from 3.6 to 6.6 amperes. 600-90000 MCBL-7 DACT phone cord, 7 feet long (2 re- quired)