FC-5C GAMEWELL-FCI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- Inherently power-limited.
- Integral digital communicator.
- Selectable transmission formats.
- Fire drill function.
- Integral voltmeter.
- Fully programmable via integral keypad.
- Auto-reset supervisory operation.
- Temporal pattern output per ANSI S3.41.
- Single person walk test.
- Alarm verification.
- Real-time clock/calendar.
- 32-Event History with time and date stamp.
- Zone disable feature via software.
- Plug-in modules.
- Serial annunciator output (optional).
- Printer interface for on or off-line printing (optional).
- Contact-by-zone module (optional).
- Surface mount technology.
- Periodic trouble reminder via software.
- Operating temperature relative humidity.
- Door back box trim ring. GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: 203-484-7161 - Fax: 203-484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
Description
The FC-5C Fire Alarm Control panel is a proven, versatile, modular control with integral communicator and remote- site Upload/Download capability. It meets the require- ments of NFPA Standard 72 for Central Station, Protected Premises, and Remote (DACT) Supervising Station Fire Alarm Systems. It is Listed to UL Standard 864, inherently power limited and meets all UL transient immunity require- ments. The integral communicator includes a wide range of se- lectable transmission formats to communicate to virtually all central stations. Other features of the communicator are: A line-active indicator for each of two phone lines, “Kiss-Off’ signal LED, dual ”low telephone voltage detect" circuitry, programmable event codes per format and se- lectable/deselectable transmission of 62 events. In addi- tion, five zones may be configured to five channels as a slave communicator with auto-resettable channels for use with UL Listed control panels. Multiple security techniques allow uploading or download- ing within one minute without affecting normal fire panel functions. Key system information that can be uploaded are: Current System Status, History, Walk Test Files and System Programming. An integral voltmeter allows voltage measurements for Zone, AC line, NAC 1, NAC2, resettable power and bat- tery. The control is housed in a red steel enclosure with back lighted panels displaying the status of vital functions. The surface mounted enclosure, (trim ring optional) with its slim appearance (3-inch depth) is designed to blend with any environment. Space is available for two (2) B-7R bat- teries. The many features of the FC-5C control provide a cost effective approach to systems design, and allow a great degree of flexibility in one enclosure. Many of these fea- tures include Class B, Style B, (with one Class A, Style D) initiating circuits and two (2) Class B, Style Y or Class A, Style Z notification appliance circuits, expandable from 1.5 to 2.5 amps each. Fully programmable via integral key- pad, the notification appliance circuits may be pro- grammed Silenceable, Non-silenceable, Auto-silence (program 5 to 30 minutes) and Silence Inhibit (60 sec- onds). An ISO 9000-2000 Company FC-5C
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
www.gamewell-fci.com 9020-0458 Rev. G page 2 of 2 Description (Continued) Also programmable are Alarm Presignal Timer, Alarm Verification Timer and Optional Trouble Reminder. Specifications Operating temperature: 32° - 120° F (0° - 49° C) Relative humidity: 85 % (non-condensing) Dimensions: Door 15 7/32" H x 14 7/32" W (38.7 x 36.1 cm) Backbox 15" H x 14 1/2" W x 3" D (38.1 cm x 36.8 cm x 7.6 cm) Trim Ring 18 1/8" H x 17 5/8" W (46.0 cm x 44.8 cm)
- Ademoco 685 • Osborne Hoffman Models 1 / 2
- Silent Knight 9000 • Radionics 6000/6500
- ITI-CS-4000 • Sescoa 3000R
- FBI CP220FB • Sur-guard MLR-2 UL Listed Receivers compatible with FC-10C: Supervision of vital components, plug-in modules, functional switches and standby batteries is pro- vided. In addition, an optional serial annunciator driver allows remote alarm annunciation.
Ordering Information
(Five zone control communicator) 700-01191 FC-5C PCB Five Zone Module, replacement board 700-01215 FC-5TR Trim Ring 700-01192 PRT-24 Printer interface module - provides RS-232 printer output. Includes cable, DB9F and DB25 adapter. 700-01193 ADM-24 Annunciator driver module 700-01194 RZA-5 Remote zone annunciator, 5 zones (requires one (1) ADM-24) Mounts on single gang box. 700-01195 RM-5F Five-relay module (contact-by-zone) 700-01196 CAC-5F Class “A” initiating circuit converter module 700-01197 SK-5C Software kit (upload/download utility) 700-01221 XRM-FC5
120 VAC, I 00 VA transformer, ex-
pands NAC total power from 3.0 to 5.0 amperes. 600-90000 MCBL-7 DACT phone cord, 7 feet long (2 required)