6870824 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Features

■Flow sensor for liquid media ■Calorimetric principle ■Adjustment via potentiometer ■LED band ■DC 3-wire, 21.6…26.4 VDC ■4…20 mA analog output ■Connector device, M12 × 1 Wiring diagram Functional principle The function of the inline flow sensors is based on the thermo-dynamic principle. Heat is generated in a measuring tube and absorbed by the flowing medium. The transported heat loss is thus a measure of the flow speed. Thus TURCK's wear-free flow sensors reliably monitor the flow of gaseous and liquid media. A low pressure drop and fast response to flow rate variations are the outstanding features of these devices.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|2 FCI-1/4TCD04A4P-LIX-H1141 | 11/07/2023 23-30 | technical changes reserved Technical data Electrical connection Connector, M12 × 1 Process Pressure 1 bar Process connection ¼'' tube connection Flow state display LED chain, red (1x), green (5x) LED display red = 4 mA 1x green > 4 mA 2x green > 8 mA 3x green > 12 mA 4x green > 16 mA 5x green = 20 mA