Features
■Sensor for gaseous media ■Calorimetric principle ■Adjustments via potentiometer ■Sensor length 115 mm ■DC 3-wire, 19.2…28.8 VDC ■4…20 mA analog output ■Connector device, M12 × 1 Wiring diagram Functional principle The function of immersion flow sensors is based on the thermodynamic principle. The sensor is heated up by a few degrees Celsius compared to the flow medium. If the medium flows past the sensor, the heat generated in the sensor is dissipated. The resulting temperature is measured and compared with the temperature of the medium. The flow condition of each medium can be derived from the temperature difference obtained. Thus, TURCK flow sensors reliably and wear-free monitor the flow of liquid or gaseous media.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|2 FCS-HA2P-LIX-H1141/AL115 | 11/07/2023 23-31 | technical changes reserved Technical data Process Pressure 3 bar Process connection G 1" female thread DIN 3852 Flow state display LED chain, red (1x), green (5x) LED display red = 4 mA 1x green > 4 mA 2x green > 8 mA 3x green > 12 mA 4x green > 16 mA 5x green = 20 mA Tests/approvals Approvals cULus UL registration number E210608