6870703 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Features

■Flow sensor for gaseous media ■Calorimetric principle ■Adjustment via potentiometer ■Mounting flange, plastic, included ■LED "power on" indication ■Plastic sensor housing ■DC 3-wire, 19.2…28.8 VDC ■4…20 mA analog output Wiring diagram Functional principle The function of immersion flow sensors is based on the thermodynamic principle. The sensor is heated up by a few degrees Celsius compared to the flow medium. If the medium flows past the sensor, the heat generated in the sensor is dissipated. The resulting temperature is measured and compared with the temperature of the medium. The flow condition of each medium can be derived from the temperature difference obtained. Thus, TURCK flow sensors reliably and wear-free monitor the flow of liquid or gaseous media.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|2 FCS-K20-LIX | 11/07/2023 23-28 | technical changes reserved Technical data Core cross-section 3 x 0.5 mm Process Pressure 1 bar Process connection PVC flange (included in delivery) Power on display LED, Green Tests/approvals Approvals cULus UL registration number E210608