6827181 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Edition • 2023-07-21T16:15:43+02:00 BL67 electronic module RS232 Interface BL67-1RS232 Type BL67-1RS232 ID 6827181 Number of channels 1 Supply voltage 24 VDC Nominal voltage Vi 24 VDC Nominal current from field supply ð 50 mA Nominal current from module bus ð 140 mA Power dissipation, typical ð 1 W Transmission level active (URS1) -15…-3 VDC Transmission level inactive (URSO) 3…15 VDC Common-mode range (UGL) -7…12 VDC Transmission signals RxD, TxD, RTS, CTS Receive/send data buffer 128/64Byte Connection type full duplex Transmission rate 300 to 115,200 bps Parameters transmission rate, diagnostics, data bits, stop bits, XON - character, XOFF - character, parity, flow con- trol Cable length (L) 15 m Electrical isolation isolation of electronics and field level via optocou- plers Output connectivity M12, M23 Number of diagnostics bytes 1 Number of parameter bytes 4 Number of input bytes 8 Number of output bytes 8 ■ Independent of the fieldbus and connection technology used ■ Protection class IP67 ■ LEDs indicate status and diagnostic ■ Electronics galvanically separated from the field level via optocouplers ■ Transmission of serial data via RS232 in- terface ■ Connection of different devices, such as printers, scanners or bar code readers Functional principle BL67 electronic modules are plugged on the purely passive base modules which in turn are connected to the field devices. The separa- tion of connection level and electronics sim- plifies maintenance considerably. Flexibility is enhanced because the user can choose be- tween base modules with different connection technologies. The electronic modules are completely inde- pendent of the higher level fieldbus through the use of gateways.

Edition • 2023-07-21T16:15:43+02:00 Dimensions (W x L x H) 32 x 91 x 59 mm Approvals CE, cULus Ambient temperature -40…+70 °C Storage temperature -40…+85 °C Relative humidity 5…95 % (internal), level RH-2, no condensation (when stored at 45 °C) Vibration test Acc. to EN 61131 - up to 5 g (at 10 to 150 Hz) for mounting on DIN rail no drilling according to EN 60715, with end bracket - up to 20 g (at 10 up to 150 Hz) for mounting on base plate or machinery Therefore every second module has to be mounted with two screws each. Shock test Acc. to IEC 60068-2-27 Drop and topple acc. to IEC 68-2-31 and free fall to IEC 68-2-32 Electromagnetic compatibility Acc. to EN 61131-2 Protection class IP67 Tightening torque fixing screw 0.9…1.2 Nm

Edition • 2023-07-21T16:15:43+02:00 Compatible base modules Dimension drawing Type Pin configuration BL67-B-1M12 6827185 1 x M12, 5-pole, female Comments Shielded cable with unterminated end (example): RSC5.501T-5/TXL Ident-No. 6632091 Pin Assignment BL67-B-1M12-8 6827193 1 x M12, 8-pole, female Comments Pins 6 & 7 are not connected up to and including VN01-02. Field-wireable connector (for example): BS8181-0 Ident-No. 6901004 Pin Assignment BL67-B-1M23 6827213 1 x M23, 12-pole, female Comments Matching connection cable (for example): FW-M23ST12Q-G-LT-ME-XX-10 Ident no. 6604070 Pin Assignment BL67-B-1M23-VI 6827290 1 x M23, 12-pole, female Comments Additionally with 24 VDC sensor supply. matching connection cable (for example): FW-M23ST12Q-G-LT-ME-XX-10 Ident no. 6604070 Pin Assignment

Edition • 2023-07-21T16:15:43+02:00 LED display LED Color Status Meaning D OFF No error message or diagnostics active. RED ON Failure of module bus communication. Check if more than 2 adja- cent electronic modules are pulled. Relevant modules are located between gateway and this module. RED FLASHING (0.5 Hz) Upcoming module diagnostics TxD OFF Data is currently not transferred. GREEN ON Data is currently transferred. RxD OFF Data is currently not received. GREEN ON Data is currently received. RTS OFF Data transfer of communication partner released by RS232 module. GREEN ON The RS232 module stops the data transfer of the communication partner. CTS OFF The communication partner has released the data transfer of the RS232 module. GREEN ON The communication partner has stopped the data transfer of the RS232 module.

Edition • 2023-07-21T16:15:43+02:00 Data mapping DATA BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input n STAT TX_CNT_ACK RX_CNT RX_BYTE_CNT n+1 Buf Ovfl Frame Err HndSh Err HW Failure Prm Err reserved n+2 Data byte 0 n+3 Data byte 1 n+4 Data byte 2 n+4 Data byte 3 n+6 Data byte 4 n+7 Data byte 5 Output m STATRES RX_CNT_ACK TCX_CNT TX_BYTE_CNT m+1 reserved RXBUF FLUSH TXBUF FLUSH m+2 Data byte 0 m+3 Data byte 1 m+4 Data byte 2 m+4 Data byte 3 m+6 Data byte 4 m+7 Data byte 5 n = Offset of input data; depending on extension of station and the corresponding fieldbus. m = Offset of output data; depending on extension of station and the corresponding fieldbus. With PROFIBUS, PROFINET and CANopen, the I/O data of this module is localized within the process data of the whole station via the hardware configuration tool of the fieldbus master. With DeviceNet™, EtherNet/IP™ and Modbus TCP a detailed mapping table can be created with the TURCK configuration tool I/O-ASSISTANT. Note: A software function module is available for simple handling of the serial interfaces (RS232, RS485 and RS422). Such a function module is available for the CoDeSys pro- grammable BL67 gateway and for the S7 PLC systems. The actual sequence of the data of the RSxxx modules in the process data of the higher-level control system may vary from that shown here. The sequence in Profibus systems is generally the reverse (byte 0 complies with byte 7 etc.).