Edition • 2023-07-21T16:06:24+02:00 I/O Hub for Connecting Digital Signals to IO-Link Master

16 Digital PNP Inputs

Operating / load voltage Total current max. 4 A per module 18…30 VDC Operating current Max. 135 mA Power dissipation, typical ð 3.2 W Inputs Number of channels 16 digital PNP inputs (EN 61131-2) Type of input diagnostics Group diagnostics Input voltage 18 … 30 VDC, e.g. from supply voltage Low level signal voltage -3…5 VDC (EN 61131-2, type 1 and 3) High level signal voltage 11…30 VDC (EN 61131-2, type 1 and 3) Max. input current 7 mA Electrical isolation inputs to FE 500VDC Firmware >= 1.4.0.0: max. 120 mA per plug Actuator power supply Max. 120 mA per slot IO-Link IO-Link specification V 1.1 Programming FDT/DTM Transmission physics corresponds to 3-wire physics (PHY2) Transmission rate COM 2 / 38.4 kbps Frame type 2.2 Minimum cycle time 2.3 ms ■ IO-Link diagnostics for short-circuit and supply voltage ■ IO-Link V1.1 Class B ■ 2 universal digital channels per port ■ Galvanic isolated Class B to support safe- ness ■ I&M data to support identification ■ Glass fiber reinforced housing ■ Shock and vibration tested ■ Fully potted module electronics ■ Protection classes IP65, IP67, IP69K ■ 2 digital inputs per slot ■ I&M data sets support installation and maintenance ■ IO-Link diagnostics for short circuit and supply voltage

Edition • 2023-07-21T16:06:24+02:00 Dimensions (W x L x H) 54 x 150 x 27.4 mm Housing material PA6-GF30 Mounting 4 mounting holes Ø 4.3 mm Ambient temperature -40…+70 °C Storage temperature -40…+85 °C Altitude Max. 5000 m Vibration test Acc. to EN 60068-2-6 Acceleration up to 20 g Shock test Acc. to EN 60068-2-27 Drop and topple Acc. to IEC 60068-2-31/IEC 60068-2-32 Electromagnetic compatibility Acc. to EN 61000-6-2/-6-4 Protection class IP67 IP69K MTTF 139 years Approvals CE, cULus UL Certificate cULus LISTED 21 W2, Encl.type 1 IND.CONT.EQ.

Edition • 2023-07-21T16:06:24+02:00 Pinning and wiring diagram Accessories Suitable IO-Link cables (Example): 2 m: RK 4T-2-RS 4T (Ident. no. U2151-3) 5 m: RK 4T-5-RS 4T (Ident. no. U2158-15) Further lengths and variants in the product catalog or on request Suitable IO-Link masters (Example): BL20-E-4IOL (Ident. no. 6827385) BL67-4IOL (Ident. no. 6827386) SDPX-IOL4-0001 (Ident. no. 6825480) Further types in the product catalog or on request M12 x 1 IO-Link Accessories Suitable Sensor supply cables (Example): 2 m: RK 4.4T-2-RS 4.4T Ident. no. (U2445) 5 m: RK 4.4T-5-RS 4.4T Ident. no. (U2167-3) Splitter YBZ2-FSM4.4/2FK4 Ident. No. (U2-07374) Further lengths and variants in the product catalog or on request Optional Accessories Closure cap VZ3 M12 Ident. no. (01202601) Labels KS9/20 Ident. no. (10267953) M12 x 1 Input

Edition • 2023-07-21T16:06:24+02:00 Module LED status LED Color Status Description OFF Power offGreen Flashing IO-Link communication OK, valid process data is sent ON IO-Link communication or module error IO-Link Red Flashing IO-Link communication OK, invalid process data or diagnosis enabled Inputs LED Status LED Color Status Description OFF Input inactive, logic 0 C1 A / B … C8 A / B Green ON Input active, logic 1 C … = Slot number, A / B = Signal LED (signal A = pin 4, B = signal pin 2)

Edition • 2023-07-21T16:06:24+02:00 Process Data Mapping of the Single Protocols For more details on the corresponding protocols see manual. Byte Bit 7 MSB Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 LSB Inputs 0 DI8 C4P2 (B) DI7 C4P4 (A) DI6 C3P2 (B) DI5 C3P4 (A) DI4 C2P2 (B) DI3 C2P4 (A) DI2 C1P2 (B) DI1 C1P4 (A)

1 DI16

C8P2 (B) DI15 C8P4 (A) DI14 C7P2 (B) DI13 C7P4 (A) DI12 C6P2 (B) DI11 C6P4 (A) DI10 C5P2 (B) DI9 C5P4 (A) C… = slot no., P… = pin no. Diagnostics / Events Class/Qualifier Mode Type Instance Code Description 0xC0 0x30 0x04 0xF4 appears 0x5110 0x80 0x30 0x04 0xB4 disappears 0x5110 Supply voltage too high 0xC0 0x30 0x04 0xF4 appears 0x5111 0x80 0x30 0x04 0xB4 disappears 0x5111 Supply voltage too low 0xC0 0x30 0x04 0xF4 appears 0x7710 0x80 0x30 0x04 0xB4 disappears 0x7710 Short circuit to GND 0xC0 0x30 0x04 0xF4 appears 0x5000 0x80 0x30 0x04 0xB4 disappears 0x5000 Hardware error Device Parameters ISDU Index Sub- Index Parameter Name Access R: Read W: Write Data Length Data Type 0x0C 0x02 Data Storage Lock R/W 1Bit Boolean Lock Parameter Upload 0: Unlocked; 1: Locked Default: 0 0x10 0x00 Vendor Name R 16 Bytes String TURCK 0x11 0x00 Vendor Text R 32 Bytes String www.turck.com 0x12 0x00 Product Name R 32 Bytes String TBIL-M1-16DIP 0x13 0x00 Product ID R 16 Bytes String 6814100 0x14 0x00 Product Text R 32 Bytes String I/O HUB 0x15 0x00 Serial Number R 16 Bytes String 0x17 0x00 FW Revision R 16 Bytes String 0x18 0x00 Application Specific Tag R/W 32 Bytes String Free text e.g for application name Default: *** 0x40 0x00 Parameter ID R/W 4 Bytes Unsigned 32 ID no. e.g. for module identification Default: 0x0000 0x41 0x00 Inverting Input R/W 2 bytes Unsigned 16 Inverting the input logic 0: Normal; 1: Inverted Default: 0x00