6814073 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 7

Technical content

Edition • 2023-07-21T16:06:00+02:00 Compact Multiprotocol I/O Module for Ethernet

8 Digital PNP Inputs

Admissible range 18…30 VDC Total current max. 4 A per voltage group V1 Voltage supply connection 2 × M8, 4-pin Operating current V1: max. 150 mA Sensor/actuator supply Supply ports C0-C3 from V1 supply Pin1 switchable per port short-circuit protect- ed, 0.5A per port Electrical isolation galvanic isolation of the voltage groups V1 and V2, voltages up to 500 VAC Fault exclusion Yes, acc. to EN ISO 13849-2, appendix D.2 System data Fieldbus transmission rate 10/100 Mbps Fieldbus connection technology 2 × M8, 4-pin Protocol detection automatic Web server default: 192.168.1.254 Service interface Ethernet via P1 or P2 BEEP functionality Supported Field Logic Controller (FLC) ARGEE Firmware Version 3.0.1.0 ARGEE Engineering Version 2.0.25.0 Modbus TCP Addressing Static IP, DHCP Supported function codes FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, FC23 Number of TCP connections 8 Input register start address 0 (0x0000 hex) Output register start address 2048 (0x0800 hex) ■ PROFINET device, EtherNet/IP device or Modbus TCP slave ■ Integrated Ethernet switch ■ Supports 10 Mbps / 100 Mbps ■ 2x M8, 4-pin, Ethernet fieldbus connection ■ Glass fiber reinforced housing ■ Shock and vibration tested ■ Fully potted module electronics ■ Protection classes IP65, IP67, IP69K ■ Pin1 switchable per I/O port ■ ATEX Zone 2/22 ■ Diagnostics of the supply per I/O port ■ Programmable ARGEE

Edition • 2023-07-21T16:06:00+02:00 Ethernet/IP Addressing acc. to EtherNet/IP specification Quick Connect (QC) < 500 ms Device Level Ring (DLR) supported Class 3 connections (TCP) 3 Class 1 connections (CIP) 10 Input Assembly Instance 103 Output Assembly Instance 104 Configuration Assembly Instance 106 PROFINET Version 2.35 Addressing DCP Conformance class B (RT) MinCycleTime 1 ms Fast Start-Up (FSU) < 500 ms Diagnostics acc. to PROFINET alarm handling Topology detection supported Automatic addressing supported Media Redundancy Protocol (MRP) supported System redundancy S2 Netload class 3 Digital inputs Number of channels 8 Connectivity inputs M12, 5-pin Input type PNP Type of input diagnostics Channel diagnostics Switching threshold EN 61131-2 Typ 3, PNP Low level signal voltage < 5 V High level signal voltage > 11 V Low level signal current < 1.5 mA High level signal current > 2 mA Input delay 0.2 ms/3 ms ms Electrical isolation Galvanically isolated to the fieldbus Voltage proof up 500 VDC Standard/Directive conformity Vibration test Acc. to EN 60068-2-6 Acceleration up to 20 g Shock test acc. to EN 60068-2-27 Drop and topple acc. to EN 60068-2-31/IEC 60068-2-32 Electromagnetic compatibility Acc. to EN 61131-2 Approvals and certificates CE, FCC, UV-resistant in accordance with DIN EN ISO 4892-2A (2013) UL Certificate cULus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ. Note on ATEX/IECEx The Quick Start Guide with information on use in Ex Zones 2 and 22 must be observed.

Edition • 2023-07-21T16:06:00+02:00 General Information Dimensions (W x L x H) 32 x 144 x 32 mm Ambient temperature -40…+70 °C Storage temperature -40…+85 °C Altitude Max. 5000 m Protection class IP65 IP67 IP69K MTTF 314 years acc. to SN 29500 (Ed. 99) 20 °C Housing material PA6-GF30 Housing color Black Male connector material Nickel-plated brass Material label Polycarbonate Halogen-free yes Mounting 2 mounting holes ￿ 4.6 mm

Edition • 2023-07-21T16:06:00+02:00 A comprehensive list of accessories for the TBEN-S product family is available at: Accessories It is strongly recommended to use only pre-assembled Ethernet cables! Ethernet cable (example): M8-M8: PSGS4M-PSGS4M-4413-1M Ident. no. U-55718 M8-RJ45: PSGS4M-RJ45S-4413-1M Ident. no.: U-55725 M8-M12: RSSD-PSGS4M-4413-1M Ident. no.: U-58840 M8 x 1 Ethernet Accessories VAUX (Pin1) supply switchable for each port Actuator and sensor cable/PUR connection cable (example): RKC4.4T-2-RSC4.4T/TXL Ident. no. 6625608 Connection cable with Y piece for single assignment VBRS4.4-2RKC4T-1/1/TEL Ident. no. 6628199 M12 x 1 Input Accessories Power supply cable (example): M8-M8 2 M (2.0 Amp) PKG 4M-2-PSG 4M Ident. No. U99-10815 M8-M8 2 M (4.0 Amp) PKGC 4M-2-PSGC 4M Ident. No. U-82319 M8 x 1 Voltage Supply

Edition • 2023-07-21T16:06:00+02:00 Module Status LED LED Color Status Description ETH1 / ETH2 Green ON Ethernet link (100 Mbps) flashing Ethernet communication (100 Mbps) Yellow ON Ethernet link (10 Mbps) flashing Ethernet communication (10 Mbps) OFF No Ethernet link BUS Green ON Active connection to a master Flashing Steady flashing: Ready Sequence of 3 flashes in 2 seconds: FLC/ARGEE active Red ON IP address conflict or Restore Mode or Modbus timeout Flashing Blink/Wink command active Red/ Green Alternating Waiting for assignment of an IP address, DHCP or BootP OFF Power off Green On No diagnostics available Red On Diagnostics available Undervoltage diagnosis response is parameter dependent LED response master in the Beep network: Green 1 Hz, 250 ms off Cyclical IO data exchange Green/red 1 Hz, 250 ms red Cyclical IO data exchange, diagnostics available Green/red 1 Hz, alternating Discovery mode active ERR Red Discovery mode active, diagnostics available PWR Green On V1 power supply OK Off V1 power supply off or V1 undervoltage LED Status I/O LED Color Status Description LED 0 … 7 Green ON Input active Red Flashing Power overload at the corresponding port. Both port LEDs are flashing. OFF Input inactive LED 7 White Flashing Blink/Wink command active

Edition • 2023-07-21T16:06:00+02:00 Process Data Mapping of the Single Protocols For more details on the corresponding protocols see manual. Modbus TCP Register Addressing (16-bit) Offset Process Input Data: 0x0000, structure acc. to general register mapping Offset Process Output Data: 0x0800: Structure acc. to general register mapping EtherNet/IP TM Word addressing (16-bit) Process input data (station -> scanner): Status word is located in front of the general process data! Reg/ Word Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 GW status 0x0000 - FCE - - CFG COM V1 - V2 - - - - - - Diag Warn 0x0001 Structure according to general register mapping Process output data (scanner -> station): Control word is located in front of the general process data! Reg/ Word Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Control 0x0000 reserved 0x0001 Structure according to general register mapping PROFINET: Byte addressing (8-bit) Offset Process Input Data: 0x0000, structure acc. to general register mapping Offset Process Output Data: 0x0000: Structure acc. to general register mapping General register mapping: Address details are relative, offset of the respective protocol is to be observed. Channel/port/pin assignment: - - - - - - - - Ch7 Ch6 Ch5 Ch4 Ch3 CH2 CH1 CH0Channel - - - - - - - - DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0 Port Pin - - - - - - - - C3 Process input data: Reg/ word Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 MSB LSB Digital inputs 8DIP 0x0000 0x0000 - - - - - - - - DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0 Diagnostics 0x0001 0x0002 - - - - - - - - - - - - VERR P1C3 VERR P1C2 VERR P1C1 VERR P1C0 Latch input 0x0002 0x0004 Counter Ch0 0x0003 0x0006 Counter value LSB 0x0004 0x0008 Counter value MSB Frequency Ch0 0x0005 0x000A Frequency MSB Frequency LSB Status 0x0006 0x000C - - - - - - - - reserved Module status 0x0007 0x000E - FCE - - - COM V1 - V2 - - - - - - DIAG Process output data: Reg/ word Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Bit 7 Bit 6 Bit 5 Bit 4 Bit3 Bit 2 Bit 1 Bit 0 MSB LSB Latch reset 0x0000 0x0000 - - - - - - - - DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0 RST VAUX control 0x0002 0x0004 - - - - - - - - - - - - VAUX1 VAUX1 VAUX1 VAUX1 Legend: V1 Undervoltage V1 CFG I/O configuration error V2 Undervoltage V2 FCE I/O-ASSISTANT Force Mode active

Edition • 2023-07-21T16:06:00+02:00 Cx Port x Px Pin x DIx Digital input channel x DOx Digital output channel x Diag Module diagnostics available ERR x Overcurrent output channel x VERRVxCHyz Overcurrent supply VAUXx channel y to z PWMOUTERR Overcurrent PWM output VERRVxPyCz Overcurrent supply VAUXx, pin y, port z VAUXxPyCz Supply VAUXx, pin y, port z CNT_RST Counter reset