Edition • 2023-07-21T15:57:28+02:00 BL compact™ fieldbus station for DeviceNet™

16 Digital PNP Outputs

BLCDN-16M8LT-8DO-0.5A-P-8DO-0.5A-P Type BLCDN-16M8LT-8DO-0.5A-P-8DO-0.5A-P ID 6811030 Nominal system voltage 24 VDC System power supply Via fieldbus and auxiliary power Voltage supply connection 2 x M12, 4-pin Admissible range V+ 11…30 VDC Nominal current V+ 30 mA Max. current V+ 4 A Admissible range Vo 11…30 VDC Nominal current Vo 200 mA Max. current Vo 4 A Fieldbus transmission rate 125/250/500 kbps Adjustment transmission rate Automatic detection Fieldbus address range 0...63 64…80 (MacID programmable) 81…99 (manufacturer specific) Fieldbus addressing 2 decimally coded rotary switches Fieldbus connection technology 2 × M12 5-pole Fieldbus termination external Service interface RS232 interface Vendor ID 48 Product type 12 Product code 11030 ■ On-machine Compact fieldbus I/O block ■ DeviceNet™ slave ■ 125 / 250 / 500 kbps ■ Two 5-pole M12 connectors for fieldbus connection ■ 2 rotary switches for node address ■ IP67 ■ M8 I/O connectors ■ LEDs indicating status and diagnostics ■ Electronics galvanically separated from the field level via optocouplers ■ 16 digital PNP outputs, 24 VDC ■ Max. 0.5A per output (4A total)

Edition • 2023-07-21T15:57:28+02:00 Digital outputs Output type PNP Type of output diagnostics Channel diagnostics Sensor supply (VSENS) 24 VDC Output current per channel 0.5 A Output voltage 24 VDC from supply voltage Output delay 3 ms Load type resistive, inductive, lamp load Load resistance, resistive > 48 ò Load resistance, inductive < 1.2 H Lamp load < 3 W Switching frequency, resistive < 200 Hz Switching frequency, inductive < 2 Hz Switching frequency, lamp load < 20 Hz Short-circuit protection yes Dimensions 168 x 71 x 32.5 mm Mounting 2 × 5.4 mm diameter holes, 1.7 Nm torque Weight 590 ± 20 g Housing material Glass-filled nylon, nickel plated brass connectors Housing color Black Material screw Nickel-plated brass Material label Polyester with polycarbonate overlay Ground label material Nickel plated brass Protection class IP67 Ambient temperature -40…+70 °C Storage temperature -40…+85 °C Relative humidity 15 to 95% (non-condensing) Vibration test Acc. to IEC 61131-2 - up to 20 g (at 10 up to 150 Hz) For mounting on base plate or machinery Shock test according to IEC 61131-2 Electromagnetic compatibility Acc. to IEC 61131-2 Approvals and certificates CE, cULus

Edition • 2023-07-21T15:57:28+02:00 Pinning and wiring diagram DeviceNet Fieldbus cable (example): RSC RKC 572-2M ident-no. U0323 or RSC-RKC572-2M ident-no. 6603629 Pin Assignment Slot 1: Digital Outputs Extension cable (example): PKG 3M-2-PSG 3M ident-no. U2515-20 or PKG3M-2-PSG3M/TEL ident-no. 6625303 Pin Assignment Wiring Diagram Slot 2: Digital Outputs Pin Assignment Auxiliary Power Extension cable (example): RKC 4.4T-2-RSC 4.4T ident-no. U5264 or RKC4.4T-2-RSC4.4T/TEL ident-no. 6625208 Pin Assignment

Edition • 2023-07-21T15:57:28+02:00 Station LED status LED Color Status Description IOs OFF No power RED ON Low power or station error RED FLASHING (1 Hz) I/O module configuration error RED FLASHING (4 Hz) No I/O module bus communication GREEN ON Station ok GREEN FLASHING Force mode active OFF No connection GREEN ON Connection established GREEN FLASHING (1 Hz) No connection established, device OK RED ON Duplicate MAC-ID MNS RED FLASHING Connection time out GREEN ON I/O active GREEN FLASHING (1 Hz) One or more I/O in Idle State RED ON One or more I/O error IO RED FLASHING One or more I/O in Faulted State I/O LED status slot 1 LED Color Status Description D1 * OFF No diagnostics active RED ON Station error/ module bus communication failure RED FLASHING (0.5Hz) Diagnostics active (Slot 1) DO channels 0...7 OFF Status of channel x = „0“ (OFF), no diagnostics active GREEN ON Status of channel x = „1“ (ON) RED ON Short circuit / overload on channel x * D1 LED also indicates gateway diagnostics I/O LED status slot 2 LED Color Status Description D2 * OFF No diagnostics active RED ON Station error/ module bus communication failure RED FLASHING (0.5Hz) Diagnostics active (Slot 2) * D2 LED also indicates gateway diagnostics

Edition • 2023-07-21T15:57:28+02:00 I/O & Diagnostic Data Map INPUT BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

0 Module number reporting diagnostic dataDiagnostics

1 Replace Sta-

  • Diagnostics Active - - - - -

2 Over Current

Slot X* (ref. Byte 0) 3 - - - - - - - - OUTPUT BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

0 DO 17 DO 16 DO 15 DO 14 DO 13 DO 12 DO 11 DO 10

1 DO 27 DO 26 DO 25 DO 24 DO 23 DO 22 DO 21 DO 20

  • The scheduled diagnostic information changes every 125 ms between Slot 1 and Slot 2, if both slots send active diagnostics.