6600 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
Features
- RoHS compliant per EU directive 2002 / 95 / EC
- 8-pin DIP international electronic package standard
- Ideal for surface and air sensing on PC boards
- Gold-plated contacts
- Up to 30,000 life cycles @ max standard amperage (120VAC)
- Up to 100,000 life cycles @ max 0.02 amperage (5 VDC) Schematic for Open on Rise Operation Schematic for Close on Rise Operation
www.sensata.com Page 2 Copyright © 2024 Sensata Technologies, Inc. SPECIFICATIONS Contact Resistance 50 milliohms max (before and after rated life) Contact Ratings Cycles 25,000 30,000 100,000 Voltage
48 VDC
120 VAC
5 VDC
Amps (resistive) 1.0 1.0 0.02 Contact Operations Either close on rise (make) or open on rise (break) Operating Temperature 40°C to 120°C (104°F to 248°F) Temperature Tolerance Standard of ±5°C (±9°F) with nominal operating temperature settings in 5°C increments Short Term / Long Term Exposure Limit Short = 260°C (500°F), 10 second duration Long = -55°C to 160°C (-67°F to 320°F) Dielectric Strength 1480 VAC 60Hz, 1 second duration terminals to case Insulation Resistance 100 Mohms at 500 VDC Contact Bounce 3 milliseconds max (make) Vibration Per Mil-Std-202, method 204D, test condition D, 10 to 2,000 Hz Shock Per Mil-Std-202, method 213, test condition C, 100 G’s for 6 millisecond duration, ½ sine wave Seal High temperature epoxy sealed for wave soldering and cleaning, moisture proof per Sensata specification S-722 (unit will not leak while submerged in 9” of water for a minimum of two minutes) Base Material PPS (Polyphenylene Sulfide), 94 VO rated Terminal Material 65% Copper, 18% Nickel Contact Material Gold-plated or overlay, silver crossbar Chemical Resistance Unit is resistance to water, salt, alcohol, ammonia, trichlorethane and most other organic solvents Soldering Heat Resistance Per Mil-Std-202F, method 210A, test condition E Weight Approximately 0.45 grams Agency Approvals cЯUus recognized E36687 VDE approval 40028966 RoHS Compliant per EU Directive 2002/95/EC
www.sensata.com Page 3 Copyright © 2024 Sensata Technologies, Inc. DIMENSIONS STANDARD PACKAGING Standard 8-Pin DIP Configuration Surface Mount (Gullwing, SMT) Configuration Standard and surface mount samples and production orders will be shipped in plastic, industry standard DIP shipping tubes.
www.sensata.com Page 4 Copyright © 2024 Sensata Technologies, Inc. STANDARD TEMPERATURE CALIBRATION TABLE Each thermostat part number consists of functional “building blocks” to enable the user to specify clearly and precisely the desired characteristics in each category. Select the proper code in each category, then transfer it to the box indicated. Unless a special requirement is indicated, the part number will be complete when the proper temperature is selected. If you have a special requirement, please call Sensata for a factory assigned number to complete the part number. Example: A 66F095 thermostat will close (make contact) on a rising temperature from 90°C to 100°C and will reset open (break contact) on a falling temperature within a window of no greater than 6°C lower than the actual close temperature and no less than 60°C ambient temperature. Special requirements require a 4 digit manufacturing dash number for ordering special features, 4 digit marking may not appear as part of the marking on the thermostat. Special requirements may include VDE, ±3.0°C (±5.4°F) operating temperature tolerance, or surface mount (gullwing, SMT). Temperature set point calibration is checked at Sensata Technologies with precision test equipment traceable to the US National Institute of Standards and Technology and Proven Methods. Because customer checking methods may differ, a typical variance allowed for correlation OPERATE (±5°C) MIN DIFFERENTIAL (°C) MIN RESET (°C) 40 4 20 45 4 20 50 4 30 55 4 30 60 4 40 65 4 40 70 4 50 75 4 50 80 6 55 85 6 55 90 6 60 95 6 60 100 6 70 105 6 70 110 6 80 115 6 85 120 9 90 ORDERING OPTIONS Example : 66F095-5588 Contact Operation Operating Temperature Basic Product Series Factory Assigned Number F = Fan (close on rise) L = Limit (open on rise) in °C, 3 digits (from above table, put “0” in front of 2 digit temps) Nondescript, 4 digit dash number assigned for a customer’s special requirements. The dash and factory assigned number is not required for ordering a standard product
66 F 0 9 5 5 5 8 8
www.sensata.com CONTACT US Americas +1 (888) 438 2214 sensors@sensata.com Europe, Middle East & Africa +31 (74) 357 8156 (Klixon+Airpax) temperature-info.eu@sensata. com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2024 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev,01/19/2024 AGENCY APPROVALS & CERTIFICATIONS RoHS Compliant per EU Directive 2002/95/EC cЯUus recognized E36687 VDE approval 40028966 WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions can result in death or serious injury.