FELCOM64 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
Power entry modules without line filter Felcom 64https://www.schurter.com /PG05 Connectors IEC Appliance Inlet C14 with modular extended Components 6421.005X.XX Appliance inlet Appliance outlet 6431.005X.XX Appliance inlet Switch Appliance outlet 6432.0X5X.XX Appliance inlet Fuseholder Switch Appliance outlet Approvals and Compliances C14 70° C F 70° C
Description
- Panel Mount : Snap-in version , from front side - 2 - 5 Functions : Appliance Inlet , Protection class I , Outlet , Line Switch 2-pole , Fu- seholder for fuse-links 5 x 20 mm 1- or 2-pole , Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm Characteristics - Modular component selection - Individual components soldered on a printed circuit board - Plug removal necessary for fuse-link replacement - Fully insulated from the rear - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Line switch with other rocker marking References Alternative: version with line filter Felcom 54 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 10 A / 250 VAC; 50 Hz Ratings UL/CSA 10 A / 125/250 VAC; 60 Hz Allowable Operation Tempe- rature -25 °C to 70 °C Insulation cover Suitable for appliances with protection class I acc. to IEC 61140 Terminal Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm , tin- plated Panel Thickness S Snap-in: 1/1.2/1.5/2/2.5/3 mm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet C14 acc. to IEC 60320-1 and F acc. to UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Fuseholder 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating cur- ves Line Switch Rocker switch 2-pole, non-illuminated, IEC 61058-1 Technical Details Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: Felcom Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40028094 UL Approvals UL UL File Number: E103791, E96454
Power entry modules without line filterFelcom 64 https://www.schurter.com /PG05 Connectors Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the en- hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Dimensions [mm]
55.0 A1)
+0.30 Variants 6421.005X.XX Mounting hole: 53.6+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 17.1 mm A: Solder terminal 3.5x0.8 mm: 12.3 mm
47.9 A1)
+0.30 Variants 6422.005X.XX Mounting hole: 46.7 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm A: Solder terminal 3.5x0.8 mm: 13.3 mm
Power entry modules without line filter Felcom 64https://www.schurter.com /PG05 Connectors
65.5 A1)
+0.30 Variants 6423.0X5X.XX Mounting hole: 65.5+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 18.15 mm A: Solder terminal 3.5x0.8 mm: 13.35 mm
58.4 A1)
+0.30 Variants 6424.0X5X.XX Mounting hole: 57 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm A: Solder terminal 3.5x0.8 mm: 13.3 mm
80.1 A1)
+0.30 Variants 6431.005X.XX Mounting hole: 80.1 A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm A: Solder terminal 3.5x0.8 mm: 13.3 mm 1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts. ±0.20
90.6 A1)
+0.30 323 +0.50 Variants 6432.0X5X.XX Mounting hole: 90.6 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 18.1 mm A: Solder terminal 3.5x0.8 mm: 13.3 mm
Power entry modules without line filterFelcom 64 https://www.schurter.com /PG05 Connectors Diagrams 6421 2)1) L LINE N 1) Load 2 2) Load 1 6422 2)1) 1) Line 2) Load 1 6423 2)1) L LINE N 1) Load 2 2) Load 1 6424 2)1) 1) Line 2) Load 1 6431 2)1) L LINE N 1) Load 2 2) Load 1 6432 2)1) L LINE N 1) Load 2 2) Load 1 Derating Curves 1-pole Admissible power acceptance in Watt02 04 06 08 0 100 I = << In I = 0.7 In I = 1.0 In 2.0 1.5 1.0 0.5 0.0 Ambient air temperature Ta °C 2-pole Admissible power acceptance in Watt per pole 02 04 06 08 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C
Power entry modules without line filter Felcom 64https://www.schurter.com /PG05 Connectors All Variants Type Connectors Connector Line Switch Fuseholder connection type Panel Thickness s [mm] Order Number Felcom 64 C14 - 2-pole 2-pole Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm 3.0 6424.0250.30
Power entry modules without line filterFelcom 64 https://www.schurter.com /PG05 Connectors Type Connectors Connector Line Switch Fuseholder connection type Panel Thickness s [mm] Order Number Felcom 64 C14 F 2-pole 2-pole Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm 2.5 6432.0250.25 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Accessories Cord retaining strain relief Flat head, A 4700.0001 Flat head, E 4700.0005 Flat head, G 4700.0007
Power entry modules without line filter Felcom 64https://www.schurter.com /PG05 Connectors Mating Inlets/Plugs Category / Description Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm 4732 IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm 4735 IEC Plug E, Cord Connector (Rewireable), Straight 9009 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm 4733 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm 4736 Plug further types to Felcom 64 ... Mating Outlets/Connectors Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to Felcom 64 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to Felcom 64 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 14.12.2017