62CTQ030 IRF | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Bulletin PD-20634 rev. A 12/01 Major Ratings and Characteristics IF(AV) Rectangular waveform 60 A (Per Device) IFRM @ TC = 120°C 60 A (Per Leg) VRRM 30 V IFSM @ tp = 5 µs sine 1500 A VF @ 30 Apk, TJ = 125°C 0.44 V TJ range - 65 to 150 °C Characteristics Values Units Description/Features This center tap Schottky rectifier has been optimized for low reverse leakage at high temperature. The proprietary barrier technology allows for reliable operation up to 150° C junction temperature. Typical applications are in switching power supplies, converters, free-wheeling diodes, and reverse bat- tery protection. 150° C T J operation Center tap TO-220 package Low forward voltage drop High purity, high temperature epoxy encapsulation for enhanced mechanical strength and moisture resistance High frequency operation Guard ring for enhanced ruggedness and long term reliabilityCase Styles 62CTQ030 TO-220 Anode 1 3 Base Common Cathode Anode Common Cathode www.irf.com
Bulletin PD-20634 rev. A 12/01 2 www.irf.com TJ Max. Junction Temperature Range -65 to 150 °C Tstg Max. Storage Temperature Range -65 to 175 °C RthJC Max. Thermal Resistance 1.2 °C/W DC operation Junction to Case (Per Leg) RthCS Typical Thermal Resistance 0.50 °C/W Mounting surface, smooth and greased Case to Heatsink wt Approximate Weight 2 (0.07) g (oz.) T Mounting Torque Min. 6 (5) Non-lubricated threads Max. 12 (10) Thermal-Mechanical Specifications Parameters Values Units Conditions Kg-cm (Ibf-in) IF(AV) Max. Average Forward (Per Leg) 30 A 50% duty cycle @ TC = 120°C, rectangular wave form Current (Per Device) 60 IFRM Peak Repetitive Forward 60 A Rated VR, square wave, 20kHz Current (Per Leg) T C = 127° C IFSM Max.Peak One Cycle Non -Repetitive 1500 A 5µs Sine or 3µs Rect. pulse Surge Current (Per Leg) 300 10ms Sine or 6ms Rect. pulse EAS Non -Repetitive Avalanche Energy 13 mJ T J = 25°C, IAS = 3Amps, L = 2.9mH (Per Leg) IAR Repetitive Avalanche Current 3 A Current decaying linearty to zero in 1 µsec (Per Leg) Frequency limited by T J max. VA = 1.5 x VR typical Absolute Maximum Ratings Parameters Values Units Conditions Following any rated load condition and with rated VRRM applied 62CTQ030 VR Max. DC Reverse Voltage (V) VRWM Max. Working Peak Reverse Voltage (V) 30 Voltage Ratings Parameters VFM Max. Forward Voltage Drop 0.46 0.5 V @ 30A T J = 25 °C 0.56 0.6 V @ 60A (1) 0.39 0.44 V @ 30A T J = 125 °C 0.54 0.59 V @ 60A IRM Max. Instantaneus Reverse Current 0.4 2.5 mA T J = 25 °C Rated DC voltage 180 350 mA T J = 125 °C CT Max. Junction Capacitance 3000 pF V R = 5VDC (test signal range 100Khz to 1Mhz) 25°C LS Typical Series Inductance 8.0 nH Measured from top of terminal to mounting plane dv/dt Max. Voltage Rate of Change 10000 V/ µs (Rated VR) Electrical Specifications Parameters Typ. Max. Units Conditions (1) Pulse Width < 300µs, Duty Cycle <2%
Bulletin PD-20634 rev. A 12/01 www.irf.com Fig. 1 - Maximum Forward Voltage Drop Characteristics Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Forward Voltage Drop - VFM (V) Instantaneous Forward Current - I F (A) Reverse Voltage - VR (V) Junction Capacitance - C T ( p F ) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics t1, Rectangular Pulse Duration (Seconds) Thermal Impedance Z thJC (°C/W) Reverse Current - I R (mA) Fig. 2 - Typical Values of Reverse Current Vs. Reverse Voltage 100 1000 Tj = 150˚C Tj = 125˚C Tj = 25˚C 0.01 0.1 100 1000 0 5 10 15 20 25 30 125˚C 100˚C 75˚C 50˚C 25˚C Tj = 150˚C 1000 10000 0 5 10 15 20 25 30 Tj = 25˚C 0.001 0.01 0.1 Single Pulse (Thermal Resistance) D = 0.75 D = 0.50 D = 0.33 D = 0.25 D = 0.20 Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc PDM
Bulletin PD-20634 rev. A 12/01 4 www.irf.com Fig. 7 - Max. Non-Repetitive Surge Current (Per Leg) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics Average Forward Current - I F(AV) (A) Allowable Case Temperature (°C) Average Forward Current - I F(AV) (A) Average Power Loss (Watts) Square Wave Pulse Duration - t p (microsec) Non-Repetitive Surge Current - I FSM (A) 100 1000 10000 10 100 1000 10000 At Any Rated Load Condition And With Rated Vrrm Applied Following Surge 0 5 10 15 20 25 30 35 40 45 DCRMS Limit D = 0.75 D = 0.50 D = 0.33 D = 0.25 D = 0.20 (2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR 100 110 120 130 140 150 160 0 5 10 15 20 25 30 35 40 45 DC see note (2) Square wave (D = 0.50) 80% Rated Vr applied
Bulletin PD-20634 rev. A 12/01 www.irf.com Outline Table 3.78 (0.15) 3.54 (0.14) 10.54 (0.41) MAX. DIA. 15.24 (0.60) 14.84 (0.58) 2.92 (0.11) 2.54 (0.10) TERM 2 14.09 (0.55) 13.47 (0.53) 3.96 (0.16) 3.55 (0.14) 0.94 (0.04) 0.69 (0.03) 4.57 (0.18) 4.32 (0.17) 3 0.61 (0.02) MAX. 5.08 (0.20) REF. 1.32 (0.05) 1.22 (0.05) 6.48 (0.25) 6.23 (0.24) 0.10 (0.004) 1.40 (0.05) 1.15 (0.04) 2.89 (0.11) 2.64 (0.10) 2.04 (0.080) MAX. Conform to JEDEC outline TO-220AB Dimensions in millimeters and (inches) Anode 1 3 Base Common Cathode Anode Common Cathode Marking Information EXAMPLE: THIS IS AN 62CTQ030 LOT CODE 1789 ASSEMBLED ON WW 19, 1998 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE PART NUMBER DATE CODE YEAR 7 = 1998 WEEK 19 LINE C
Bulletin PD-20634 rev. A 12/01 6 www.irf.com IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 12/01 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. Ordering Information Table Device Code 1 524 3 1 - Essential Part Number 2 - Common Cathode 3 - T = TO-220 4 - Q = Schottky Q Series 5 - Voltage Rating
62 C T Q 030
030 = 30V