Power entry modules without line filter 6145https://www.schurter.com /PG05 Connectors IEC Appliance Inlet C14 with Circuit Breaker TA45 Approvals and Compliances C14 70° C
Description
- Panel Mount : Screw-on mounting from front side - 2 Functions : Appliance Inlet Protection class I , circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired - Unwired versions available on request - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 References Alternative: version with line filter 5145 We recommend for new applications the new type DF11 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC 10 A / 250 VAC; 50 Hz Ratings UL/CSA 15 A / 250 VAC; 60 Hz Dielectric Strength > 1.5 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- rature -10 °C to 55 °C IP-Protection from front side IP 40 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 6 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non- illuminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 6145 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40040061 UL Approvals UL UL File Number: E96454
Power entry modules without line filter6145 https://www.schurter.com /PG05 Connectors Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimensions [mm] 43.136 Detail A 13.9 6.3x0.8mm 6.3x0.8mm 67.5 24.2 91.5 ø 3.3 ø 6.1 M3 / ø 3.6 +0.10 ±0.1 R3 -0.5 29 -0.2 * --- Version TA45 with undervoltage release
Power entry modules without line filter 6145https://www.schurter.com /PG05 Connectors Diagrams 1) 2) L' P1 N' P2 N L PE PE' 1) Line 2) Load
Power entry modules without line filter6145 https://www.schurter.com /PG05 Connectors ABT W F 150 C0 Colours Switch front Rocker W black white – B black black – 6 black – orange transp. F embossed / Relief H printed / bedruckt white / weiss K printed / bedruckt black / schwarz L printed / bedruckt white / weiss Surface Illustration Colour of print Rocker legend l O ON OFF ON OFF l O M printed black P printed white R printed black Surface Illustration Colour of print Rated current circuit breaker of equipment Without release: code C0 Undervoltage release Remote trip release UE ZA Code Rated voltage Un
- • •
- • •
- • •
240 V AC
230 V AC
120 V AC
l O OI OI Position of the r ocker legend e.g F In Code 0,1 J01 0,2 J02 0,3 J03 0,4 J04 0,5 J05 0,6 J06 0,7 J07 0,8 J08 0,9 J09 1,0 J10 1,1 J11 1,2 J12 In Code 1,3 J13 1,4 J14 1,5 J15 1,6 J16 1,7 J17 1,8 J18 1,9 J19 2,0 J20 2,1 J21 2,2 J22 2,3 J23 2,5 J25 In Code 2,8 J28 3,0 030 3,5 035 4,0 040 4,5 045 5,0 050 6,0 060 6,5 065 7,0 070 7,5 075 8,0 080 9,0 090 In Code 10,0 100 11,0 110 12,0 120 13,0 130 14,0 140 15,0 150 20,0 200 Table 1 Selection for type T A45 Order example
- Circuit Breaker of Equipment
- 2-pole, rocker actuated
- Quick connect terminal Other types on r equest Without illumination With illumination 220…240 V 110…120 V Diagram Thermal overload pr otection 1-pole 2-pole ABT ABD A12 A32 A14 A34 P2 P1 P2 P1 P2 P1 P2 P1b P2 P1b a P2 P1c
Power entry modules without line filter 6145https://www.schurter.com /PG05 Connectors Technical data (continued) Circuit breaker Effect of ambient temperatur e 1) The unit is calibrated for an ambient temperatu re of +23 °C. To deter mine the rated curr ent for a lower or higher ambient tempera- ture, use a correction factor fr om the table below. * Ambient temperatur e [°C] Correction factor –10 0,89 – 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 Order code TA45 (2-pole rocker-switch without accessories) Configuration code (example) * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperatur e has been reached. 1) Example Rated current at +23 °C 6,0 A Ambient temperatur e +40 °C Correction factor 1,08 Chosen rated curr ent at + 40 °C ambient temperatur e 6 A x 1,08 = 6,5 A Type Tripping characteristics In < 3 A Tripping characteristics 10’000 2000 1000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 Multiple of rated current [ x In ] 10854321,32 Tripping time Type TA45 Rated current In < 3 A 1-pole protected 2-pole protected Ambient temp. +23 °C 10’000 2’000 1’000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 [ x In ] 10854321,32 Type TA45 Rated current I > 3... < 15 A 1-pole protected 2-pole protected Ambient temp. +23 °C Multiple of rated current Tripping time n Terminal PE 1 Quick-connect terminal 6.3x0.8 mm Terminal N 1 Quick-connect terminals 6.3x0.8mm, without connection to TA45 4 connection to TA45 non insulated Terminal L 1 Quick-connect terminals 6.3x0.8mm, without connection to TA45 4 connection to TA45 non insulated see table 1 6145 - ABTWF150C0 - 000 - 111 - 00 Packaging unit 20 Pcs Accessories 0859.0074
Power entry modules without line filter6145 https://www.schurter.com /PG05 Connectors Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to 6145 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to 6145 ... Mating Outlets/Connectors shuttered Power Cord Overview complete Power cord with IEC connector C17, V-Lock, straight VAC17KS Power Cord further types to 6145 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 01.12.2017