AS 2293.1 4.3.1 it 5 oF a eX 8 2 yp <= S =— oa CIRCUIT SENSE 3 PROLONG yee & -<9—— AS 2293.1 3 AS 2293.1 = xo, > 2.3.3 3 > é g ‘ é FEATURES MANUAL TEST ry) CIRCUIT SENSE » Easy configuration and control & Manually operated discharge- G Each unit has § circuit ° - " test for 90 / 120 min duration sensing inputs «= Allin one unit to meet compliance needs = Extend period to allow walk around inspection * Suitable single-point and centrally supplied systems PROLONG — comPLiANT = 5sensing circuits, link up 6 units for 30 sense circuits (2) Provision for time delay, Reb AS/NZS 60598.2.22 = Brown-out trigger to meet AS/NZS 60598.2.22 Clause 22.7 remains in emergency mode AS 2293.1 CONTACT E: sales@evolt.com.au P: 1300 4EVOLT (438 658) F: +61 2 9502 1154 ektor.com.au
ee OPERATIONAL INFORMATION Voltage 240V~ 50Hz g ) Mca s } 4 « ) Ambient temp. Oto 40°C 3 [ [ensjensaanl Class 2 2 Wiring Terminal block (6 mm a) 8 SOmm 28mm vemm IP rating 1P20 z
9 MOUNTING :
— 2002 35mm DINrail 2003 Field mounted EMERGENCY a Rated duration 90/120 min 45mm [160mm Power consumption 2.3 W : a RELAY an ee Connection ‘Screw terminal for 1-4 mm? cable
5 Type Nor-tatching Load 2A 240V~ max
LL | BEOUICTRANGE 2002 0.2kg/6.1kg 2003 0.69 kg / 8.5 kg ‘ORDER CODE PRODUCT NUMBER SKU QTY oo EV-EM-TIMER* NOTE: For more information on the chemical resistance of our polycarbonate or Emergency Test Switch 9336462020029 2002-20 ‘our compliance documentation, please see our website EV-EM-TIMER-ASM* Emergency Test Switch 9336462020036 20034 with DIN Enclosure ACCESSORY RANGE GENERAL FEATURES ORDER CODE DESCRIPTION, = Easy configuration and control = Extended period to allow walk around 6122 Emergency Test Switch RU45 Interlink cable = Alkin-one unit to meet compliance needs OO = Manually operated discharge test (90/120 min duration) = Sensing circuits, inks up to 6 units for 30 sense circuits = Brown-out trigger ensures AS/NZS 60598.2.22 Clause 22.17 is met = Prolong, provision for time-delay to remain in emergency mode for lighting requiring cooldown BUILT TO LAST = Long life electronics = 10 Years Design Life ~ 100,000 hours at max. ambient *Contactor not included ektor.com.au evo It E: sales@evolt.com.au . . P:1300 4EVOLT (438 658) _the electrical evolution Extoris dedicated to continuous product improvement. Datasheet is subject ‘0 change without notice, E&OE. Images are for illustrative purposes only