Product: RKWU 19-242 M23 Power Single-Ended Cordset: Female, angled, 19-pin, black body, 120 V AC/DC, 16x8 A + 3x10 A; PUR black cable, 16x0.5 mm² + 3x1.0 mm² Product Description M23 Power Single-Ended Cordset: Female, angled, 19-pin, black body, 120 V AC/DC, 16x8 A + 3x10 A; PUR black cable, 16x0.5 mm² + 3x1.0 mm² Technical Drawing Technical Specifications Face View Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 Pin 15 Pin 16 Pin 17 Pin 18 Pin 19 violet red grey red-blue green blue grey-pink white-green white-yellow white-grey black green-yellow yellow-brown brown-green white yellow pink grey-brown brown Technical Data Product Family: Power Connector Product Sub Family: M23 Power Brand: Lumberg Automation Connector Type: Cordset, single ended Type of Contact / Gender: female Connector Design: angled Number of Pins: 19 Shielding: Unshielded Attachment Type: Coupling Nut Rated Voltage: 125 V Rated Impulse Voltage: 1.5 kV Operating Voltage: 120 V AC/DC Rated Current*: 16 x 8 A (pin-Ø 1 mm), 3 x 10 A (contact-Ø 1.5 mm) Insulation Resistance: ˃ 10^9 Ohm Mating Cycles: ≤ 100 Ambient Temperature (Operation)*: -25°C to +80°C

Protection Degree / IP Rating**: IP67 Pollution Degree: 3 acc. to DIN EN 60664-1 (VDE 0110-1) Clearance / Creepage Distance: acc. to DIN EN 60664-1 (VDE 0110-1) Overvoltage Category: II acc. to DIN EN 60664-1 (VDE 0110-1) Materials Contact Base Material: 16 x CuSn/3 x CuZn Contact Plating: Cu/Au Contact Bearer Material: PA 66 Contact Bearer Color: black Flammability Class (Contact Bearer): UL 94-HB Molded Body Material: TPU Molded Body Color: black Flammability Class (Molded Body): UL 94-HB Attachment Material: CuZn, nickel-plated O-Ring Material: FKM Cable Data Cable Number: 242 Conductor Size: 16x0.5mm² + 3x1.0 mm² Number of Wires: 19 Minimal Bending Radius (Fixed Inst): ˃ 5 x D Minimal Bending Radius (Flexible Inst): ˃ 10 x D Cycles (Bending): ˃ 2 M Conductor material: Cu Cable Jacket Material: PUR Cable Jacket Color: black Cable Diameter D: Ø 11.60 ±0.30 mm Wire Insulation Material: PP Insulated Wire Diameter: 16x Ø1.45 mm + 3x Ø1.95 mm Ambient Temperature (Fixed Installation): -50°C to +80°C Ambient Temperature (Flex Installation): -25°C to +80°C Ambient Temperature (Drag Chain Inst): max. +60°C UL Cable Type: AWM: 21198 / 20549 Flammability Class (Cable Jacket): IEC 60332-2, VDE 0482-265-2-2, EN 50265-2-2, FT2; flame-retardant Safety & Environmental Compliance RoHS Compliant: yes Resistances Halogenfree: IEC 60754-1, VDE 0482-267, EN 50267-2-1 Notes Note Derating: * Notice derating Protection Degree / IP Rating Note: ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. Note: Do not connect / disconnect under load. Particularities: When the connector is unlocked and in risk of pollution the connector has to be covered with a protective cap ≥ IP54. Variants Item # Item Description Cable Length

934636535 RKWU 19-242/1 M 1 m

61260 RKWU 19-242/2 M 2 m

60706 RKWU 19-242/5 M 5 m

60693 RKWU 19-242/10 M 10 m

60694 RKWU 19-242/15 M 15 m

60695 RKWU 19-242/20 M 20 m

61213 RKWU 19-242/25 M 25 m

61216 RKWU 19-242/30 M 30 m

61218 RKWU 19-242/35 M 35 m

61214 RKWU 19-242/40 M 40 m

91618 RKWU 19-242/50 M 50 m

© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.