60K07C COOPER | Alldatasheet
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
SB98107 Rev. A HRC FORM II Current Limiting Fuses HRC FORM II Ceramic Body Form No. HCR FORM II Page 1 of 3 BIF Doc #4131 Bussmann® Dimensional Data CATALOG SYMBOL: H07CB, K07CB, KO7CRB, L14CB, M14CB, L09CB, M09CB, P09CB, P11CB AND R11CB CERAMIC BODY FUSE 600 VOLTS A.C. OR LESS 250 VOLTS D.C. CURRENT LIMITING 200,000 AMPS RMS SYMMETRICAL CSA C22.2 NO. 106M1992 BS88:2, IEC269:2
Applications
- HRC FORM II fuses are often used to protect motor control circuits, together with contactors and overload protection relays.
- Type 2 coordination - per IEC 947-4. EDG F A H C J B H07CB (Offset Blades) E DG F A H C J B K07CB/K07CRB/L14CB/M14CB (Offset Blades) DG C A F B E H L09CB/M09CB/P09CB (Center Blades) F B E G C A K D K H P11CB/R11CB (Center Blades)
SB98107 Rev. A HRC FORM II Current Limiting Fuses HRC FORM II Ceramic Body Bussmann® Form No. HCR FORM II Page 2 of 3 BIF Doc #4131 Ratings, Categories and Dimensions Current Dimensions in Inches and (mm) Ratings Catalog CSA (Amps) Number ABCDEF G HJ K Category 2 2H07CB 4 4H07CB 6 6H07CB 20 20H07CB 25 25H07CB 30 30H07CB 250 250P09CB 400 400P09CB 250 250P11CB 400 400P11CB
SB98107 Rev. A HRC FORM II Current Limiting Fuses HRC FORM II Ceramic Body Bussmann® Form No. HCR FORM II Page 3 of 3 BIF Doc #4131 The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All ot her copies of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applicatio ns. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select- ed, it should be tested by the user in all possible applications. Peak Let-Through Curves Time/Current-Curves 100 1,000 10,000 100,000 1,000,000 100 200 400 600 FUSE RATING (AMPERES) AMPERE 2 SECONDS (I2t) Total I2t at 600V Total I2t at 460V Pre-Arcing I2t 100,000 10,000 1,000 100 1,000 100 CURRENT IN AMPERES TIME IN SECONDS .01 100 200 400 600 AMPERE RATING Energy Let-Through Curves 100 100 PROSPECTIVE CURRENT (SYM. RMS KA) PEAK CURRENT (KA) .01 100 200 400 600 AMPERE RATING