Features

Ultrafast Soft Recovery Diode VR Cathode to Anode Voltage 200 V IF(AV) Continuous Forward Current, TC = 127°C 60 A IFSM Single Pulse Forward Current, TC = 25°C 800 IFRM c Maximum Repetitive Forward Current 120 TJ, TSTG Operating Junction and Storage Temperatures - 55 to 175 °C Parameters Max Units

  • Ultrafast Recovery
  • 175°C Operating Junction Temperature
  • Lead-Free ("PbF" suffix) Benefits
  • Reduced RFI and EMI
  • Higher Frequency Operation
  • Reduced Snubbing
  • Reduced Parts Count These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are not significant portion of the total losses. c Square Wave, 20kHz TO-247AC (Modified) 60EPU02PbF 60APU02PbF TO-247AC www.irf.com ANODE ANODE BASE COMMON CATHODE 31ANODE BASE COMMON CATHODE CATHODE

60EPU02PbF, 60APU02PbF Bulletin PD-21079 08/05 2 www.irf.com Parameters Min Typ Max Units RthJC Thermal Resistance, Junction to Case 0.70 K/W RthCS d Thermal Resistance, Case to Heatsink 0.2 Wt Weight 5.5 g 0.2 (oz) T Mounting Torque 1.2 N*m Marking Device 60EPU02, 60APU02 VBR, Vr Breakdown Voltage, 200 - - V I R = 100µA Blocking Voltage VF Forward Voltage - 0.98 1.08 V I F = 60A - 0.81 0.88 V I F = 60A, TJ = 175°C IR Reverse Leakage Current - - 50 µA V R = VR Rated --2 m A T J = 150°C, VR = VR Rated CT Junction Capacitance - 87 - pF V R = 200V LS Series Inductance - 8.0 - nH Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters Min Typ Max Units Test Conditions trr Reverse Recovery Time - - 35 ns I F = 1.0A, diF/dt = 200A/µs, VR = 30V -2 8- T J = 25°C -5 0- T J = 125°C IRRM Peak Recovery Current - 4 - A T J = 25°C -8- T J = 125°C Qrr Reverse Recovery Charge - 59 - nC T J = 25°C - 220 - T J = 125°C Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) IF = 60A VR = 160V diF /dt = 200A/µs Parameters Min Typ Max Units Test Conditions Thermal - Mechanical Characteristics d Mounting Surface, Flat, Smooth and Greased Measured lead to lead 5mm from package body

60EPU02PbF, 60APU02PbF www.irf.com Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Forward Voltage Drop - VFM (V) Instantaneous Forward Current - I F (A) Reverse Voltage - VR (V) Reverse Voltage - VR (V) Junction Capacitance - C T (pF) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics t1, Rectangular Pulse Duration (Seconds) Thermal Impedance Z thJC (°C/W) Reverse Current - I R (µA) 0.001 0.01 0.1 100 1000 0 50 100 150 200 125˚C 25˚C T = 175˚CJ 100 1000 10000 1 10 100 1000 T = 25˚CJ 0.01 0.1 Single Pulse (Thermal Resistance) D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 PDM Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 100 1000 0 0.5 1 1.5 2 2.5 T = 175˚C T = 125˚C T = 25˚C J J J

60EPU02PbF, 60APU02PbF Bulletin PD-21079 08/05 4 www.irf.com Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR Average Power Loss ( Watts ) trr ( ns ) Qrr ( nC ) Average Forward Current - IF(AV) (A) Allowable Case Temperature (°C) Average Forward Current - IF(AV) (A) di F /dt (A/µs )di F /dt (A/µs ) Fig. 8 - Typical Stored Charge vs. di F /dtFig. 7 - Typical Reverse Recovery time vs. di F /dt 100 110 120 130 140 150 160 170 180 0 2 04 06 08 0 1 0 DC Square wave (D = 0.50) 80% Rated Vr applied see note (3) 100 1000 Vr = 160V Tj = 125˚C Tj = 25˚C IF = 90A IF = 60A IF = 30A 100 200 300 400 500 600 700 800 100 1000 IF = 90A IF = 60A IF = 30A Vr = 160V Tj = 125˚C Tj = 25˚C 100 0 2 04 06 08 0 1 0 DC RMS Limit D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50

60EPU02PbF, 60APU02PbF www.irf.com Fig. 10 - Reverse Recovery Waveform and Definitions IRFP250 D.U.T. L = 70µH V = 200VR 0.01Ω G D S dif/dt ADJUST ta tb trr Qrr IF IRRM IRRM0.5 di(rec)M/dt

0.75 IRRM

Fig. 9- Reverse Recovery Parameter Test Circuit Reverse Recovery Circuit di F /dt di F /dt 4. Qrr - Area under curve defined by t rr and IRRM 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current Q rr = t rr x I RRM

60EPU02PbF, 60APU02PbF Bulletin PD-21079 08/05 6 www.irf.com ANODE BASE COMMON CATHODE CATHODE ANODE ANODE BASE COMMON CATHODE 15.90 (0.626) 15.30 (0.602) 14.20 (0.559) 14.80 ( 0.583) 3.70 (0.145) 4.30 (0.170) 5.30 ( 0.208) 5.70 (0.225) 5.50 ( 0.217) 4.50 (0.177) (2 PLCS.) 3.55 (0.139) 3.65 (0.144) 2.20 (0.087) MAX. 1.00 (0.039) 1.40 (0.056) 0.40 (0.213) 0.80 ( 0.032) 4.70 ( 0.185) 5.30 (0.209) 1.5 ( 0.059) 2.5 ( 0.098) 2.40 (0.095) MAX. 10.86 (0.427) 10.94 ( 0.430) 20.30 (0.800) 19.70 (0.775) DIA. 12 3 15.90 (0.626) 15.30 (0.602) 14.20 (0.559) 14.80 (0.583) 3.70 (0.145) 4.30 (0.170) 5.30 ( 0.208) 5.70 (0.225) 5.50 ( 0.217) 4.50 (0.177) (2 PLCS.) 3.55 (0.139) 3.65 (0.144) 2.20 (0.087) MAX. 1.00 (0.039) 1.40 (0.056) 0.40 (0.213) 0.80 ( 0.032) 4.70 ( 0.185) 5.30 (0.209) 1.5 ( 0.059) 2.5 ( 0.098) 2.40 (0.095) MA X. 10 .86 (0 .427 ) 10. 94 ( 0.430) 20.30 (0.800) 19.70 (0.775) 1 3 DIA. Outline Table 60EPU02PbF Dimensions in millimeters and inches 60APU02PbF

60EPU02PbF, 60APU02PbF www.irf.com Marking Information LOT CODE ASSEMBLY INTERNATIONAL RECTIFIEREXAMPLE: IN ASSEMBLY LINE "H" ASSEMBLED ON WW 35, 2000 LOT CODE 5657 WITH ASSEMBLY LOGO PART NUMBER YEAR 0 = 2000 P = LEAD-FREE WEEK 35 LINE H P035H 56 57 DATE CODE THIS IS A 60EPU02 60EPU02 RECTIFIER INTERNATIONAL ASSEMBLY LOT CODE EXAMPLE: IN ASSEMBLY LINE "H" ASSEMBLED ON WW 35, 2000 WITH ASSEMBLY LOT CODE 5657 LOGO P = LEAD-FREE YEAR 0 = 2000 PART NUMBER LINE H WEEK 35 P035H 56 57 DATE CODE THIS IS A 60APU02 60APU02 Ordering Information Table

60 E P U 02 PbF

1 - Current Rating (60 = 60A) 2 - Circuit Configuration: E = Single Diode A = Single Diode, 3 pins P = TO-247AC (Modified) 4 - Type of Silicon: U = UltraFast Recovery 5 - Voltage Rating (02 = 200V) 6 - y none = Standard Production y PbF = Lead-Free

60EPU02PbF, 60APU02PbF Bulletin PD-21079 08/05 8 www.irf.com IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 08/05 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site.