60EPF06 IRF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

Bulletin I2113 rev. D 04/99 QUIETIR Series 60EPF.. 60CPF.. VF < 1.1V @ 30A trr = 70ns VRRM 200 to 600V Major Ratings and Characteristics IF(AV) Sinusoidal waveform 60 A VRRM 200 to 600 V IFSM 830 A VF @ 30 A, TJ = 25°C 1.1 V trr @ 1A, 100A/µs 70 ns T J - 40 to 150 °C Description/Features The 60EPF.. & 60CPF.. fast soft recovery QUIETIR rectifier series has been optimized for combined short reverse recovery time and low forward voltage drop. The glass passivation ensures stable reliable operation in the most severe temperature and power cycling conditions. Typical applications are both: Output rectification and freewheeling in inverters, choppers and converters and input rectifications where severe restrictions on conducted EMI should be met. Characteristics 60EPF.. Units 60CPF.. TO-247AC (Modified) Package Outline 60CPF.. 60EPF..

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com IF(AV) Max. Average Forward Current 60 A @ T C = 106° C, 180° conduction half sine wave IFSM Max. Peak One Cycle Non-Repetitive 700 10ms Sine pulse, rated V RRM applied Surge Current 830 10ms Sine pulse, no voltage reapplied I2t Max. I 2t for fusing 2450 10ms Sine pulse, rated VRRM applied 3460 10ms Sine pulse, no voltage reapplied I2√t Max. I2√t for fusing 34600 A 2√s t = 0.1 to 10ms, no voltage reapplied Part Number VRRM , maximum V RSM , maximum non repetitive IRRM peak reverse voltage peak reverse voltage 150°C VV m A 60EPF02, 60CPF02 200 300 5 60EPF04, 60CPF04 400 500 60EPF06, 60CPF06 600 700 Voltage Ratings Absolute Maximum Ratings Electrical Specifications Typical Recovery Characteristics Parameters 60.PF.. Units Conditions A A2s VFM Max. Forward Voltage Drop 1.3 V @ 60A, T J = 25°C rt Forward slope resistance 5.0 m Ω VF(TO) Threshold voltage 0.88 V IRM Max. Reverse Leakage Current 0.1 T J = 25 °C

5.0 T J = 150 °C

Parameters 60.PF.. Units Conditions TJ = 150°C VR = rated VRRMmA trr Reverse Recovery Time 180 ns I F @ 60Apk Irr Reverse Recovery Current 3.4 A @ 25A/ µs Q rr Reverse Recovery Charge 0.5 µC @ 25°C S Snap Factor tb/ta 0.5 typical Parameters 60.PF.. Units Conditions ta tb trr t Ifm dir dt Qrr Irm (REC)

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com TJ Max. Junction Temperature Range - 40 to 150 °C Tstg Max. Storage Temperature Range - 40 to 150 °C R thJC Max. Thermal Resistance Junction 0.4 °C/W DC operation to Case R thJA Max. Thermal Resistance Junction 40 °C/W to Ambient R thCS Typical Thermal Resistance, Case to 0.2 °C/W Mounting surface , smooth and greased Heatsink wt Approximate Weight 6 (0.21) g (oz.) T Mounting Torque Min. 6 (5) Max. 12 (10) Case Style TO-247AC JEDEC (Modified) Thermal-Mechanical Specifications Parameters 60.PF.. Units Conditions Kg-cm (Ibf-in) Fig. 3 - Forward Power Loss Characteristics Fig. 4 - Forward Power Loss Characteristics Fig. 1 - Current Rating Characteristics Fig. 2 - Current Rating Characteristics 100 110 120 130 140 150 0 1 02 03 04 05 06 07 0 30° 60° 90° 120° 180° Maximum Allowable Case Temperature (°C) Conduction Angle Average Forward Current (A) 60.PF.. Series R (DC) = 0.4 K/WthJC 100 110 120 130 140 150 0 2 04 06 08 0 1 0 0 DC 30° 60° 90° 120° 180° Maximum Allowable Case Temperature (°C) Condu ction Period Average Forward Current (A) 60.PF.. Series R (DC) = 0.4 K/WthJC 0 1 02 03 04 05 06 07 0 Average Forward Current (A) RMS Limit Maximum Average Forward Power Loss (W) Conduction Angle 180° 120° 90° 60° 30° 60.PF.. Series T = 150°C J 100 120 140 0 2 04 06 08 0 1 0 0 DC 180° 120° 90° 60° 30° Average Forward Current (A) RMS Limit Maximum Average Forward Power Loss (W) Conduction Period 60.PF.. Series T = 150°CJ

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com Fig. 7 - Forward Voltage Drop Characteristics Fig. 5 - Maximum Non-Repetitive Surge Current Fig. 6 - Maximum Non-Repetitive Surge Current Fig. 9 - Recovery Time Characteristics, TJ = 150°CFig. 8 - Recovery Time Characteristics, TJ = 25°C 200 300 400 500 600 700 800 11 0 1 0 0 Peak Half Sine Wave Forward Current (A) Number Of Equal Amplitude Half Cycle Current Pulses (N) 60.PF.. Series Initial T = 175°C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s At Any Rated Load Condition And With Rated V Applied Following Surge.RRM J 100 200 300 400 500 600 700 800 900 0.01 0.1 1 Peak Half Sine Wave Forward Current (A) Pulse Train Duration ( s) Maximum Non Repetitive Surge Current Initial T = 195°C No Voltage Reapplied Rated V ReappliedRRM Versus Pulse Train Duration. 60.PF.. Series J 100 1000 00 . 511 . 522 . 533 . 54 T = 25°CJ Instantaneous Forward Current (A) Instantaneous Forward Voltage (V) T = 150°CJ 60.PF.. Series 0.05 0.1 0.15 0.2 0 40 80 120 160 200 10 A Maximum Reverse Recovery Time - Trr (µs) Rate Of Fall Of Forward Current - di/dt (A/µs) I = 60 A 30 A 5 A 1 A FM 60.PF.. Series T = 25 °CJ 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 10 20 30 40 50 60 70 80 90 100 10 A Maximum Reverse Recovery Time - Trr (µs) Rate Of Fall Of Forward Current - di/dt (A/µs) I = 60 A 30 A 5 A 1 A FM 60.PF.. Series T = 150 °CJ

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com Fig. 14 - Thermal Impedance ZthJC Characteristics Fig. 12 - Recovery Current Characteristics, TJ = 25°C Fig. 13 - Recovery Current Characteristics, TJ = 150°C Fig. 10 - Recovery Charge Characteristics, TJ = 25°C Fig. 11 - Recovery Charge Characteristics, TJ = 150°C 0 40 80 120 160 200 10 A Rate Of Fall Of Forward Current - di/dt (A/µs) I = 60 A 30 A 5 A 1 A Maximum Reverse Recovery Charge - Qrr (µC) FM 60.PF.. Series T = 25 °CJ 10 20 30 40 50 60 70 80 90 100 10 A Rate Of Fall Of Forward Current - di/dt (A/µs) I = 60 A 30 A 5 A 1 A Maximum Reverse Recovery Charge - Qrr (µC) FM60.PF.. Series T = 150 °CJ 0 40 80 120 160 200 10 A Rate Of Fall Of Forward Current - di/dt (A/µs) I = 60 A 30 A 5 A 1 A Maximum Reverse Recovery Current - Irr (A) FM 60.PF.. Series T = 25 °CJ 10 20 30 40 50 60 70 80 90 100 10 A Rate Of Fall Of Forward Current - di/dt (A/µs) I = 60 A 30 A 5 A 1 A Maximum Reverse Recovery Current - Irr (A) FM 60.PF.. Series T = 150 °CJ 0.01 0.1 0.001 0.01 0.1 1 10 Square Wave Pulse Duration (s) thJCTransient Thermal Impedance Z (K/W) Single Pulse 60.PF.. Series Steady State Value (DC Operation) D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com Outline T able Dimensions in millimeters and (inches) Ordering Information T able

60 E P F 06

2 - Circuit Configuration: E = Single Diode P = TO-247AC (Modified) 4 - Type of Silicon: F = Fast Recovery 5 - Voltage code: Code x 100 = VRRM 02 = 200V 04 = 400V 06 = 600V 15.90 (0.626) 15.30 (0.602) 14.20 (0.559) 14.80 (0.583) 3.70 (0.145) 4.30 (0.170) 5.30 ( 0.208) 5.70 (0.225) 5.50 ( 0.217) 4.50 (0.177) (2 PLCS.) 3. 55 (0 .13 9) 3. 65 (0.14 4) 2.20 (0.087) MA X. 1.00 (0.039) 1.40 (0.056) 0.40 (0.213) 0.80 (0.032) 4.70 (0.185) 5.30 (0.209) 1.5 (0.059) 2.5 (0.098) 2.40 (0.095) MA X. 10.86 (0.427) 10. 94 ( 0.430) 20.30 (0.800) 19.70 (0.775) 1 3 DI A. CATHODE ANODE BASE CATHODE

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com Outline Table Dimensions in millimeters and (inches) Ordering Information T able

60 C P F 06

2 - Circuit Configuration: C = Single Diode, 3 pins P = TO-247AC (Modified) 4 - Type of Silicon: F = Fast Recovery 5 - Voltage code: Code x 100 = VRRM 02 = 200V 04 = 400V 06 = 600V CATHODE BASE CATHODE ANODE 15.90 (0.626) 15.30 (0.602) 14.20 (0.559) 14.80 ( 0.583) 3.70 (0.145) 4.30 (0.170) 5.30 (0.208) 5.70 (0.225) 5.50 ( 0.217) 4.50 (0.177) (2 PLCS.) 3.55 (0.139) 3.65 (0.144) 2.20 (0.087) MAX. 1.00 (0.039) 1.40 (0.056) 0.40 (0.213) 0.80 ( 0.032) 4.70 (0.185) 5.30 (0.209) 1.5 ( 0.059) 2.5 ( 0.098) 2.40 (0.095) MAX. 10.86 (0.427) 10.94 ( 0.430) 20.30 (0.800) 19.70 (0.775) DIA. 12 3 Base Cathode Anode Anode

60EPF.. 60CPF.. QUIETIR Series Bulletin I2113 rev. D 04/99 www.irf.com EUROPEAN HEADQUARTERS: Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408. IR CANADA: 15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801. IR GERMANY: Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933. IR ITALY:Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220. IR FAR EAST:K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086. IR SOUTHEAST ASIA: 1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630. http://www.irf.com Fax-On-Demand: +44 1883 733420 Data and specifications subject to change without notice.