Bulletin PD-20506 rev. A 02/03
60 Amp
IF(AV) Rectangular waveform 60 A Per Device VRRM 15 V IFSM @ tp = 5 µs sine 1850 A VF @ 30 Apk, TJ = 125°C 0.28 V (typical) per leg TJ range - 55 to 125 °C Characteristics Values Units Major Ratings and Characteristics Description/ Features This center tap Schottky rectifier has been optimized for low forward voltage drop. The proprietary sub-micron technology allows for low power loss both in forward and reverse conduction. 125 °C T J operation Center tap configuration Low forward voltage drop High frequency operation High purity, high temperature epoxy encapsulation for enhanced mechanical strength and moisture resistance www.irf.com Case Styles 60CTT015 TO-220 Anode 1 3 Base Common Cathode Anode Common Cathode
Bulletin PD-20506 rev. A 02/03 2 www.irf.com VFM Max. Forward Voltage Drop 0.36 0.40 V @ 30A T J = 25°C (Per Leg) (1) 0.44 0.49 V @ 60A 0.28 0.32 V @ 30A T J = 125°C 0.39 0.45 V @ 60A IRM Max. Reverse Leakage Current 2.0 3.5 mA T J = 25 °C V R = rated VR (Per Leg) (1) 450 600 mA T J = 125 °C CT Junction Capacitance (Per Leg) 2900 - pF V R =10VDC(test signal range100KHz to1MHz)25°C LS Series Inductance (Per Leg) 8.0 - nH Measured lead to lead 5mm from package body dv/dt Max. Voltage Rate of Change - 10000 V/µs (Rated VR) Thermal-Mechanical Specifications IF(AV) Max. Average Forward (Per Leg) 30 A 50% duty cycle @ T C = 105°C, rectangular wave form Current (Per Device) 60 IFSM Max. Peak One Cycle Non-Repetitive 1850 5µs Sine or 3µs Rect. pulse Surge Current (Per Leg) 360 10ms Sine or 6ms Rect. pulse EAS Non-Repetitive Avalanche Energy 9.0 mJ T J = 25 °C, IAS = 2 Amps, L = 4.5 mH (Per Leg) IAR Repetitive Avalanche Current 2 A Current decaying linearly to zero in 1 µsec (Per Leg) Frequency limited by T J max. VA = 1.5 x VR typical Part number 60CTT015 VR Max. DC Reverse Voltage (V) @ TJ = 125°C 15 Voltage Ratings TJ Max. Junction Temperature Range -55 to 125 °C Tstg Max. Storage Temperature Range -55 to 150 °C RthJC Max. Thermal Resistance Junction 1.2 °C/W DC operation to Case (Per Leg) RthCS Typical Thermal Resistance, Case 0.5 °C/W Mounting surface , smooth and greased to Heatsink wt Approximate Weight 2 (0.07) g (oz.) T Mounting Torque Min. 6 (5) Max. 12 (10) Case Style TO-220AB Kg-cm (Ibf-in) Absolute Maximum Ratings Parameters Values Units Conditions A Parameters Values Units Conditions Following any rated load condition and with rated VRRM applied Parameters Typ Max Units Conditions Electrical Specifications (1) Pulse Width < 300µs, Duty Cycle < 2%
Bulletin PD-20506 rev. A 02/03 3www.irf.com Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage (Per Leg) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage (Per Leg) Fig. 4 - Max. Thermal Impedance ZthJC Characteristics (Per Leg) Fig. 1 - Max. Forward Voltage Drop Characteristics (Per Leg) Forward Voltage Drop - VFM (V) Instantaneous Forward Current - I F (A) Reverse Voltage - VR (V) Reverse Current - I R (mA) Reverse Voltage - VR (V) Junction Capacitance - C T (p F) t1, Rectangular Pulse Duration (Seconds) Thermal Impedance Z thJC (°C/W) 1000 10000 4 6 8 1 01 21 41 6 T = 25˚CJ 100 1000 T = 125˚C T = 25˚C J J 100 1000 0 2 4 6 8 1 01 21 41 6 100˚C 75˚C 50˚C 25˚C Tj = 125˚C 0.01 0.1 Single Pulse (Thermal Resistance) D = 0.75 D = 0.50 D = 0.33 D = 0.25 D = 0.20 Notes: 1. Duty factor D = t1 / t2 2. Peak Tj = Pdm x ZthJC + Tc PDM
Bulletin PD-20506 rev. A 02/03 4 www.irf.com Fig. 7 - Max. Non-Repetitive Surge Current (Per Leg) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current (Per Leg) Fig. 8 - Unclamped Inductive Test Circuit Fig. 6 - Forward Power Loss Characteristics (Per Leg) FREE- WHEEL DIODE 40HF L40S02CU R R E NT MONIT OR HIGH-S PEED S WIT CHIRFP460 L DUT Rg = 25 o h m Vd = 25 Volt+ (2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ 80% VR applied Average Forward Current - I F(AV) (A) Allowable Case Temperature (°C) Average Forward Current - IF(AV) (A) Average Power Loss (Watts) Square Wave Pulse Duration - tp (microsec) Non-Repetitive Surge Current - I FSM (A) 100 105 110 115 120 125 130 0 5 10 15 20 25 30 35 40 45 DC see note (2) Square wave (D = 0.50) 80% Vr applied 100 1000 10000 10 100 1000 10000 At Any Rated Load Condition And With Rated Vrrm Applied Following Surge 0 1 02 03 04 05 0 DC RMS Limit D = 0.20 D = 0.25 D = 0.33 D = 0.50 D = 0.75
Bulletin PD-20506 rev. A 02/03 5www.irf.com IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 02/03 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. Outline Table 3.78 (0.15) 3.54 (0.14) 10.54 (0.41) MAX. DIA. 15.24 (0.60) 14.84 (0.58) 2.92 (0.11) 2.54 (0.10) TERM 2 14.09 (0.55) 13.47 (0.53) 3.96 (0.16) 3.55 (0.14) 0.94 (0.04) 0.69 (0.03) 4.57 (0.18) 4.32 (0.17) 3 0.61 (0.02) MAX. 5.08 (0.20) REF. 1.32 (0.05) 1.22 (0.05) 6.48 (0.25) 6.23 (0.24) 0.10 (0.004) 1.40 (0.05) 1.15 (0.04) 2.89 (0.11) 2.64 (0.10) 2.04 (0.080) MAX. Conform to JEDEC outline TO-220AB Dimensions in millimeters and (inches) Anode 1 3 Base Common Cathode Anode Common Cathode